{"id":1582065413,"title":"HANNA HI 764 Checker HC ® - Nitrite. ULR","handle":"hi764","description":"\u003cp\u003eThe HANNA HI 764 Checker®HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI 764 Checker®HC is accurate and affordable.\u003c\/p\u003e\n\u003cp\u003eThe HI 764 Checker®HC portable handheld colorimeter features a resolution of 1 ppb and uses an adaptation of EPA Diazotization method 354.1.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of this Checker®HC fits in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eThe HI 764 Checker®HC is extremely simple to use. First. zero the instrument with your water sample. Next. add the reagent. Last. place the vial into the HI 764 Checker®HC. press the button and read the results. It’s that easy.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 764 Checker®HC is supplied with sample cuvettes with caps (2). powder reagents for Nitrite (6). battery and instructions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/ist764_02_06_10.pdf\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-7_medium.png?11580704866198517246\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 200 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±10 ppb ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of EPA Diazotization method 354.1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2016-07-12T14:39:00+12:00","created_at":"2015-09-01T15:02:16+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Category_pH","Manufacturer_Hanna Instruments","Type_Buffers"],"price":8900,"price_min":8900,"price_max":8900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857030853,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI764","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 764 Checker HC ® - Nitrite. ULR","public_title":null,"options":["Default Title"],"price":8900,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-nitrit-924_1-1_2015.jpeg?v=1443494429"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-nitrit-924_1-1_2015.jpeg?v=1443494429","options":["Title"],"media":[{"alt":"HI 764 Checker HC ® - Nitrite. ULR - Acorn Scientific","id":21265776739,"position":1,"preview_image":{"aspect_ratio":0.855,"height":799,"width":683,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-nitrit-924_1-1_2015.jpeg?v=1443494429"},"aspect_ratio":0.855,"height":799,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-nitrit-924_1-1_2015.jpeg?v=1443494429","width":683}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe HANNA HI 764 Checker®HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI 764 Checker®HC is accurate and affordable.\u003c\/p\u003e\n\u003cp\u003eThe HI 764 Checker®HC portable handheld colorimeter features a resolution of 1 ppb and uses an adaptation of EPA Diazotization method 354.1.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of this Checker®HC fits in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eThe HI 764 Checker®HC is extremely simple to use. First. zero the instrument with your water sample. Next. add the reagent. Last. place the vial into the HI 764 Checker®HC. press the button and read the results. It’s that easy.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 764 Checker®HC is supplied with sample cuvettes with caps (2). powder reagents for Nitrite (6). battery and instructions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/ist764_02_06_10.pdf\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-7_medium.png?11580704866198517246\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 200 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±10 ppb ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of EPA Diazotization method 354.1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}