Email info@acornsci.com for orders and inquiries.

{"id":1582159109,"title":"HI 83225-02 Photometer for NPK Analysis - Greenhouses \u0026 Hydroponics","handle":"hi83225-02","description":"\u003cp style=\"text-align: justify;\"\u003eNitrogen. phosphorus. and potassium (NPK) are often the first three factors considered when making recommendations to growers. Compared to the HI 83215. the HI 83225 provides control over three additional important growing factors: sulfur (most common as sulfates). calcium and magnesium.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 83225 is designed for the hydroponics and greenhouse industries to measure seven nutrients commonly present in fertilizer enriched solutions. It can measure fifteen different methods using specific liquid or powder reagents. and has four measuring channels for a wide range of tests.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe optical system of HI 83225 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results. HI 83225 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu. and the Help Menu provides assistance for every step in the measurement process.  This meter can be connected to a PC via a USB cable. where the data can be managed with optional HI 92000 Windows® compatible software.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 83225-02\u003c\/strong\u003e (230V) is supplied with sample cuvettes and caps (4 ea.). sample preparation kit. cloth for wiping cuvettes (1). scissors. AC\/DC power adapter and instruction manual\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 83225-100\u003c\/strong\u003e  kit includes 10 mL cuvettes and caps (4 ea.). 100 mL plastic beaker. 170 mL plastic beaker. 100 mL graduated cylinder. 60 mL syringe with screw rim. 5 mL syringe. funnel. filter discs (25). spoon. pipettes (2). carbon powder packets (50) and demineralizer bottle with filter cap for approximately 12 liters of deionized water.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eup to 5 tungsten lamps with different narrow band interference filters.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eexternal 12 VDC power adapter or built-in rechargeable battery\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); max 90% RH non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 x 200 x 110 mm (9.2 x 7.87 x 4.33\")\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.9 Kg (2 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eMulti Parameter Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003cth\u003eReagent Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalcium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 400 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eOxalate\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 937521-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnesium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCalmagite\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 937520-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 300 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 30.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e20 to 200 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 20.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSulfate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93751-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e\u003cspan\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man83225_04_06_10.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e","published_at":"2016-09-01T16:17:14+12:00","created_at":"2015-09-01T15:14:52+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["brand_Hanna","category_photometers","Manufacturer_Hanna Instruments"],"price":142500,"price_min":142500,"price_max":142500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857285061,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI83225-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HI 83225-02 Photometer for NPK Analysis - Greenhouses \u0026 Hydroponics","public_title":null,"options":["Default Title"],"price":142500,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi83225_400-1_2015.jpeg?v=1443495556"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi83225_400-1_2015.jpeg?v=1443495556","options":["Title"],"media":[{"alt":null,"id":21296906339,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi83225_400-1_2015.jpeg?v=1443495556"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi83225_400-1_2015.jpeg?v=1443495556","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003eNitrogen. phosphorus. and potassium (NPK) are often the first three factors considered when making recommendations to growers. Compared to the HI 83215. the HI 83225 provides control over three additional important growing factors: sulfur (most common as sulfates). calcium and magnesium.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 83225 is designed for the hydroponics and greenhouse industries to measure seven nutrients commonly present in fertilizer enriched solutions. It can measure fifteen different methods using specific liquid or powder reagents. and has four measuring channels for a wide range of tests.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe optical system of HI 83225 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results. HI 83225 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu. and the Help Menu provides assistance for every step in the measurement process.  This meter can be connected to a PC via a USB cable. where the data can be managed with optional HI 92000 Windows® compatible software.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 83225-02\u003c\/strong\u003e (230V) is supplied with sample cuvettes and caps (4 ea.). sample preparation kit. cloth for wiping cuvettes (1). scissors. AC\/DC power adapter and instruction manual\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 83225-100\u003c\/strong\u003e  kit includes 10 mL cuvettes and caps (4 ea.). 100 mL plastic beaker. 170 mL plastic beaker. 100 mL graduated cylinder. 60 mL syringe with screw rim. 5 mL syringe. funnel. filter discs (25). spoon. pipettes (2). carbon powder packets (50) and demineralizer bottle with filter cap for approximately 12 liters of deionized water.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eup to 5 tungsten lamps with different narrow band interference filters.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eexternal 12 VDC power adapter or built-in rechargeable battery\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); max 90% RH non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 x 200 x 110 mm (9.2 x 7.87 x 4.33\")\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.9 Kg (2 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eMulti Parameter Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003cth\u003eReagent Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalcium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 400 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eOxalate\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 937521-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnesium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCalmagite\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 937520-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 300 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 30.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e20 to 200 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 20.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSulfate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93751-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e\u003cspan\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man83225_04_06_10.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e"}

HI 83225-02 Photometer for NPK Analysis - Greenhouses & Hydroponics

Product Description

Nitrogen. phosphorus. and potassium (NPK) are often the first three factors considered when making recommendations to growers. Compared to the HI 83215. the HI 83225 provides control over three additional important growing factors: sulfur (most common as sulfates). calcium and magnesium.

HI 83225 is designed for the hydroponics and greenhouse industries to measure seven nutrients commonly present in fertilizer enriched solutions. It can measure fifteen different methods using specific liquid or powder reagents. and has four measuring channels for a wide range of tests.

The optical system of HI 83225 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results. HI 83225 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu. and the Help Menu provides assistance for every step in the measurement process.  This meter can be connected to a PC via a USB cable. where the data can be managed with optional HI 92000 Windows® compatible software.

 

Order Information: HI 83225-02 (230V) is supplied with sample cuvettes and caps (4 ea.). sample preparation kit. cloth for wiping cuvettes (1). scissors. AC/DC power adapter and instruction manual

HI 83225-100  kit includes 10 mL cuvettes and caps (4 ea.). 100 mL plastic beaker. 170 mL plastic beaker. 100 mL graduated cylinder. 60 mL syringe with screw rim. 5 mL syringe. funnel. filter discs (25). spoon. pipettes (2). carbon powder packets (50) and demineralizer bottle with filter cap for approximately 12 liters of deionized water.

Specification :

Light Source   up to 5 tungsten lamps with different narrow band interference filters.
Light Detector   silicon photocell
Power Supply   external 12 VDC power adapter or built-in rechargeable battery
Environment   0 to 50°C (32 to 122°F); max 90% RH non-condensing
Dimensions   235 x 200 x 110 mm (9.2 x 7.87 x 4.33")
Weight   0.9 Kg (2 lbs.)

Multi Parameter Specifications

Parameter Range Method Reagent Code
Ammonia HR 0 to 100 mg/L (ppm) Nessler HI 93715-01
Ammonia LR 0.0 to 10.0 mg/L (ppm) Nessler HI 93715-01
Ammonia MR 0.0 to 50.0 mg/L (ppm) Nessler HI 93715-01
Calcium 0 to 400 mg/L (ppm) Oxalate HI 937521-01
Magnesium 0 to 150 mg/L (ppm) Calmagite HI 937520-01
Nitrate HR 0 to 300 mg/L (ppm) Cadmium Reduction HI 93728-01
Nitrate LR 0.0 to 30.0 mg/L (ppm) Cadmium Reduction HI 93728-01
Nitrate MR 0 to 150 mg/L (ppm) Cadmium Reduction HI 93728-01
Phosphorus HR 0 to 100 mg/L (ppm) Amino Acid HI 93706-01
Phosphorus LR 0.0 to 10.0 mg/L (ppm) Amino Acid HI 93706-01
Phosphorus MR 0.0 to 50.0 mg/L (ppm) Amino Acid HI 93706-01
Potassium HR 20 to 200 mg/L (ppm) Turbidimetric HI 93750-01
Potassium LR 0.0 to 20.0 mg/L (ppm) Turbidimetric HI 93750-01
Potassium MR 0 to 100 mg/L (ppm) Turbidimetric HI 93750-01
Sulfate 0 to 100 mg/L (ppm) Turbidimetric HI 93751-01
Product Manuals

  Manual: Download

This product is available upon request. Contact us for more information.