Email info@acornsci.com for orders and inquiries.

{"id":6625905442915,"title":"BIOBASE BK-V1000 Spectrophotometer","handle":"copy-of-biobase-electronic-density-specific-gravity-balance","description":"\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e* Imported \u0026amp; Environmental Deuteriumlamp, preventing the Ozone inhalation.\u003c\/p\u003e\n\u003cp\u003e* High-class grating with wholly hermetic light path design, ensures the super low stray light.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* \u003c\/span\u003e\u003cspan\u003eHigh-class grating with wholly hermetic light path design, ensures the super low stray light\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Real-time monitoring of the lifetime of Deuterium lamp and Tungsten lamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Socket-Type Deuterium lamp and Tungsten lamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Wavelength calibration, wavelength setting, change of light and dark source, automatic calibration\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*SiO2 coating of Optical Mirror, reduce the effect of external influences\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"1\" bordercolor=\"#666666\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBK-UV1000\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eBK-V1000\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eBK-UV1200\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eBK-V1200\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical System\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eSingle Beam, Grating1200 lines\/mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWavelength Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200-1020nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e325-1000nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e200-1020nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e320-1020nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpectral Bandwidth\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e4nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWavelength Accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e±1.8nm \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cp\u003e±1.5nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWavelength Repeatability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e≤0.5nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePhotometric Accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePhotometric Repeatability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs),≤0.2% T (0-100% T)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStray Light\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e≤0.1 % T @ 360nm; 220nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cp\u003e≤0.2% T @ 360nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e± 0.001A \/ h @ 500nm \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e± 0.001A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDisplay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePhotometric Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eT, A, C, E\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePhotometric Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e0-200%T,-0.301-3.0A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDetector\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eSilicon Photodiode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLight Source\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eDeuterium Lamp, Tungsten Lamp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eMembrane Keypad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOutput\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eParallel Print,USB1.0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptional Accessories\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eSolid Sample Holder, Micro Cell Holder,10-100mm Cell Holder,PC software\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePacking Size(W*D*H)(mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e560*430*320\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e560*430*320\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e560*430*320\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e560*430*320\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eGross Weight(kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e11.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e11.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2021-08-26T12:21:30+12:00","created_at":"2021-08-26T12:16:26+12:00","vendor":"Biobase","type":"Spectrophotometers","tags":["Category_Spectrophotometers","Manufacturer_Biobase","Promotions_Now in Stock!","Type_Devices"],"price":150000,"price_min":150000,"price_max":150000,"available":true,"price_varies":false,"compare_at_price":189700,"compare_at_price_min":189700,"compare_at_price_max":189700,"compare_at_price_varies":false,"variants":[{"id":39539299713123,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"BK-V1000","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"BIOBASE BK-V1000 Spectrophotometer","public_title":null,"options":["Default Title"],"price":150000,"weight":0,"compare_at_price":189700,"inventory_quantity":-1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/i_20180725014306_3406..jpg?v=1629937506"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/i_20180725014306_3406..jpg?v=1629937506","options":["Title"],"media":[{"alt":null,"id":20800095322211,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/i_20180725014306_3406..jpg?v=1629937506"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/i_20180725014306_3406..jpg?v=1629937506","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e* Imported \u0026amp; Environmental Deuteriumlamp, preventing the Ozone inhalation.\u003c\/p\u003e\n\u003cp\u003e* High-class grating with wholly hermetic light path design, ensures the super low stray light.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* \u003c\/span\u003e\u003cspan\u003eHigh-class grating with wholly hermetic light path design, ensures the super low stray light\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Real-time monitoring of the lifetime of Deuterium lamp and Tungsten lamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Socket-Type Deuterium lamp and Tungsten lamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Wavelength calibration, wavelength setting, change of light and dark source, automatic calibration\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*SiO2 coating of Optical Mirror, reduce the effect of external influences\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"1\" bordercolor=\"#666666\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBK-UV1000\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eBK-V1000\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eBK-UV1200\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eBK-V1200\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical System\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eSingle Beam, Grating1200 lines\/mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWavelength Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200-1020nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e325-1000nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e200-1020nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e320-1020nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpectral Bandwidth\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e4nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWavelength Accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e±1.8nm \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cp\u003e±1.5nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWavelength Repeatability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e≤0.5nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePhotometric Accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePhotometric Repeatability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs),≤0.2% T (0-100% T)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStray Light\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e≤0.1 % T @ 360nm; 220nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cp\u003e≤0.2% T @ 360nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e± 0.001A \/ h @ 500nm \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e± 0.001A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDisplay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePhotometric Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eT, A, C, E\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePhotometric Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003e0-200%T,-0.301-3.0A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDetector\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eSilicon Photodiode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLight Source\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eDeuterium Lamp, Tungsten Lamp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eMembrane Keypad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOutput\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eParallel Print,USB1.0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptional Accessories\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\n\u003cp\u003eSolid Sample Holder, Micro Cell Holder,10-100mm Cell Holder,PC software\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePacking Size(W*D*H)(mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e560*430*320\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e560*430*320\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e560*430*320\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e560*430*320\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eGross Weight(kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e11.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e11.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e"}

BIOBASE BK-V1000 Spectrophotometer

Product Description

Features:

* Imported & Environmental Deuteriumlamp, preventing the Ozone inhalation.

* High-class grating with wholly hermetic light path design, ensures the super low stray light.

High-class grating with wholly hermetic light path design, ensures the super low stray light.

*Real-time monitoring of the lifetime of Deuterium lamp and Tungsten lamp

*Socket-Type Deuterium lamp and Tungsten lamp

*Wavelength calibration, wavelength setting, change of light and dark source, automatic calibration

*SiO2 coating of Optical Mirror, reduce the effect of external influences

Model

BK-UV1000

BK-V1000

BK-UV1200

BK-V1200

Optical System

Single Beam, Grating1200 lines/mm

Wavelength Range

200-1020nm

325-1000nm

200-1020nm

320-1020nm

Spectral Bandwidth

4nm

Wavelength Accuracy

±1.8nm 

±1.5nm

Wavelength Repeatability

≤0.5nm

Photometric Accuracy

± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T) 

Photometric Repeatability

0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs),≤0.2% T (0-100% T)

Stray Light

≤0.1 % T @ 360nm; 220nm

≤0.2% T @ 360nm

Stability

± 0.001A / h @ 500nm 

Noise

± 0.001A

Display

LCD

Photometric Mode

T, A, C, E

Photometric Range

0-200%T,-0.301-3.0A

Detector

Silicon Photodiode

Light Source

Deuterium Lamp, Tungsten Lamp

Input

Membrane Keypad

Output

Parallel Print,USB1.0

Optional Accessories

Solid Sample Holder, Micro Cell Holder,10-100mm Cell Holder,PC software

Packing Size(W*D*H)(mm)

560*430*320

560*430*320

560*430*320

560*430*320

Gross Weight(kg)

12

11.5

12

11.5


$1,500.00 $1,897.00
Maximum quantity available reached.
Liquid error (layout/theme line 139): Could not find asset snippets/beae_footer.liquid