Email info@acornsci.com for orders and inquiries.

{"id":9045193195816,"title":"True Indicating DRY HEAT Spore Ampoules","handle":"true-indicating-steam-spore-ampoules","description":"\u003cp\u003eTrue Indicating offers spore ampoules for use in monitoring the efficacy of steam sterilization processes. Spore ampoules are a self contained biological indicator ideal for use in validation of liquid sterilization cycles. Ampoules may be placed in larger containers such as vials but are also suitable for monitoring non-liquid loads. No activation is required after exposure of the spore ampoule to a sterilization process. Remove the ampoule post exposure from the sterilizer and incubate.\u003c\/p\u003e\n\u003cp\u003eSpore ampoules are manufactured using hermetically sealed type i borosilicate glass containing a modified soybean casein digest broth with pH indicator \u0026amp; the specified population of geobacillus stearothermophilus or bacillus subtilis spores. Growth is evident by either turbidity and\/or a shift in colour.\u003c\/p\u003e\n\u003cp\u003eSpore ampoules are labelled with 24 months of shelf life. Store ampoules under refrigerated conditions (5 ± 3˚c). Spore ampoules are compliant with ANSI\/AAMI\/ISO\/EN and USP where applicable.\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCompliant with USP, ISO 11138-1 and ISO 11138-4\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for High Temperature Dry Heat Sterilization Processes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMinimum Incubation Period of 72 Hours\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConsistent Population, Purity and Resistance Ampule to Ampule\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eBacillus Atrophaeus, Cell Line 9372\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"113\"\u003e\n\u003cp\u003e\u003cspan\u003eProduct Code\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e\n\u003cp\u003e\u003cspan\u003ePopulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\"\u003e\n\u003cp\u003e\u003cspan\u003ePackaging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"113\"\u003e\n\u003cp\u003e\u003cspan\u003eAAD-06\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e\n\u003cp\u003e\u003cspan\u003e10\u003c\/span\u003e⁶\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\"\u003e\n\u003cp\u003e\u003cspan\u003e50 Ampoules + 50 Tubes of Growth Medium\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2024-04-10T12:56:55+12:00","created_at":"2024-04-10T12:45:13+12:00","vendor":"True Indicating","type":"Sterilisation Consumables","tags":["Category_Sterilisation Consumables","Industry_Healthcare","Manufacturer_True Indicating","Type_Biological Indicator","Type_DRY HEAT"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":48094217470248,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":null,"requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"True Indicating DRY HEAT Spore Ampoules","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/files\/ScreenShot2021-01-22at1_01_16PM.webp?v=1712710591"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/files\/ScreenShot2021-01-22at1_01_16PM.webp?v=1712710591","options":["Title"],"media":[{"alt":null,"id":38414753923368,"position":1,"preview_image":{"aspect_ratio":1.038,"height":443,"width":460,"src":"\/\/acornsci.co.nz\/cdn\/shop\/files\/ScreenShot2021-01-22at1_01_16PM.webp?v=1712710591"},"aspect_ratio":1.038,"height":443,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/files\/ScreenShot2021-01-22at1_01_16PM.webp?v=1712710591","width":460}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eTrue Indicating offers spore ampoules for use in monitoring the efficacy of steam sterilization processes. Spore ampoules are a self contained biological indicator ideal for use in validation of liquid sterilization cycles. Ampoules may be placed in larger containers such as vials but are also suitable for monitoring non-liquid loads. No activation is required after exposure of the spore ampoule to a sterilization process. Remove the ampoule post exposure from the sterilizer and incubate.\u003c\/p\u003e\n\u003cp\u003eSpore ampoules are manufactured using hermetically sealed type i borosilicate glass containing a modified soybean casein digest broth with pH indicator \u0026amp; the specified population of geobacillus stearothermophilus or bacillus subtilis spores. Growth is evident by either turbidity and\/or a shift in colour.\u003c\/p\u003e\n\u003cp\u003eSpore ampoules are labelled with 24 months of shelf life. Store ampoules under refrigerated conditions (5 ± 3˚c). Spore ampoules are compliant with ANSI\/AAMI\/ISO\/EN and USP where applicable.\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCompliant with USP, ISO 11138-1 and ISO 11138-4\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for High Temperature Dry Heat Sterilization Processes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMinimum Incubation Period of 72 Hours\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConsistent Population, Purity and Resistance Ampule to Ampule\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eBacillus Atrophaeus, Cell Line 9372\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"113\"\u003e\n\u003cp\u003e\u003cspan\u003eProduct Code\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e\n\u003cp\u003e\u003cspan\u003ePopulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\"\u003e\n\u003cp\u003e\u003cspan\u003ePackaging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"113\"\u003e\n\u003cp\u003e\u003cspan\u003eAAD-06\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e\n\u003cp\u003e\u003cspan\u003e10\u003c\/span\u003e⁶\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\"\u003e\n\u003cp\u003e\u003cspan\u003e50 Ampoules + 50 Tubes of Growth Medium\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

True Indicating DRY HEAT Spore Ampoules

Product Description

True Indicating offers spore ampoules for use in monitoring the efficacy of steam sterilization processes. Spore ampoules are a self contained biological indicator ideal for use in validation of liquid sterilization cycles. Ampoules may be placed in larger containers such as vials but are also suitable for monitoring non-liquid loads. No activation is required after exposure of the spore ampoule to a sterilization process. Remove the ampoule post exposure from the sterilizer and incubate.

Spore ampoules are manufactured using hermetically sealed type i borosilicate glass containing a modified soybean casein digest broth with pH indicator & the specified population of geobacillus stearothermophilus or bacillus subtilis spores. Growth is evident by either turbidity and/or a shift in colour.

Spore ampoules are labelled with 24 months of shelf life. Store ampoules under refrigerated conditions (5 ± 3˚c). Spore ampoules are compliant with ANSI/AAMI/ISO/EN and USP where applicable.

  • Compliant with USP, ISO 11138-1 and ISO 11138-4
  • Suitable for High Temperature Dry Heat Sterilization Processes
  • Minimum Incubation Period of 72 Hours
  • Consistent Population, Purity and Resistance Ampule to Ampule

Bacillus Atrophaeus, Cell Line 9372

Product Code

Population

Packaging

AAD-06

10

50 Ampoules + 50 Tubes of Growth Medium

This product is available upon request. Contact us for more information.