{"product_id":"bl-983319-1","title":"HANNA BL983319-1 TDS Mini Controller 0.0 to 1999 mg\/L (ppm) - 230V","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEasy to handle\u003c\/li\u003e\n\u003cli\u003eFire retardant casing\u003c\/li\u003e\n\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cli\u003eSplash resistant cover\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDosing Relay: Contact close when measure: \u0026lt; set point\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThis instrument has been designed for TDS control in hydroponics. horticulture and water conditioning. Compact in size. it can be mounted in confined spaces or even right next to the vat or barrel containing the chemicals. These meters permit automatic control of installations previously checked manually.\u003c\/p\u003e\u003cp\u003eReadings are shown on the display and the multicolored LED continuously indicates if the mini controller is in measurement. dosing or alarm mode.\u003c\/p\u003e\u003cp\u003eUsers can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations. because it permits operators to enable or disable the dosing relay according to your need.\u003c\/p\u003e\u003cp\u003eThe overtime control system advises users when the relay is active too long. helping to prevent over dosage.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eBL 983319-1 ( 115\/230V). is supplied with mounting brackets. transparent cover and instruction manual.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manBL_983319.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manBL_983319.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 1999 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7634-00 EC\/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. 5 to 50°C (41 to 122°F) with ß = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Relay\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected). 250 Vac. 30 VDC Contact close when measure: \u0026lt; set point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 1999 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertime\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable. typically from 5 to approx. 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSee Chart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":5832160965,"sku":"BL983319-1","price":304.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/tds-miniregler-bis-1999-mgl-12v-28_1-1_2015.jpeg?v=1469854319","url":"https:\/\/acornsci.co.nz\/products\/bl-983319-1","provider":"Acorn Scientific","version":"1.0","type":"link"}