{"id":2031633605,"title":"TDS Mini Controller 0.0 to 10.00 g\/L (ppt) - 230V","handle":"bl983318-1","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEasy to handle\u003c\/li\u003e\n\u003cli\u003eFire retardant casing\u003c\/li\u003e\n\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cli\u003eSplash resistant cover\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003eBL 983318 is a mini controller that has been designed for easy. affordable installation in tight spaces. ideal for simple yet effective process control.\u003c\/p\u003e\u003cp\u003eBL 983318 features ATC (Automatic Temperature Compensation) and simple one point calibration performed through the trimmer.\u003c\/p\u003e\u003cp\u003eThe multicolored LED continuously indicates if the controller is in measurement. dosing or alarm mode.\u003c\/p\u003e\u003cp\u003eWiring and external device connections are extremely simple to perform through the terminals on the rear of the instrument.\u003c\/p\u003e\u003cp\u003eUsers can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations. because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\u003cp\u003eThe overtime control system advises users when the relay is active too long. helping to prevent over-dosage.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eBL 983318-1 ( 115\/230V) are supplied with mounting brackets. transparent cover and instruction manual.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manBL_983318.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manBL_983318.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 ppt (0 to 10.000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 ppt (10 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7632-00 EC\/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. 5 to 50°C (41 to 122°F) with ß = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Relay\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected). 250 Vac. 30 VDC contact close when measure \u0026gt; set point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 10 ppt (10.000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertime\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable. typically from 5 to approx. 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSee Chart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T15:09:20+12:00","created_at":"2015-09-07T15:08:19+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters"],"price":30400,"price_min":30400,"price_max":30400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5832160773,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"BL983318-1","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"TDS Mini Controller 0.0 to 10.00 g\/L (ppt) - 230V","public_title":null,"options":["Default Title"],"price":30400,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/tds-miniregler-bis-1999-mgl-12v-22_1-1_2015_5f031f3e-6105-4e98-8fa1-31ff69de6b4a.jpeg?v=1443494981","\/\/acornsci.co.nz\/cdn\/shop\/products\/dim251dfb345dec34_2015_b71378fb-4421-498d-a304-e8ade9b19803.png?v=1443494981","\/\/acornsci.co.nz\/cdn\/shop\/products\/dim51dfb347ef6d6_2015_e9bfd9fd-fd73-4547-8bf9-eb87f37e085e.png?v=1443494981"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/tds-miniregler-bis-1999-mgl-12v-22_1-1_2015_5f031f3e-6105-4e98-8fa1-31ff69de6b4a.jpeg?v=1443494981","options":["Title"],"media":[{"alt":null,"id":25252855907,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/tds-miniregler-bis-1999-mgl-12v-22_1-1_2015_5f031f3e-6105-4e98-8fa1-31ff69de6b4a.jpeg?v=1443494981"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/tds-miniregler-bis-1999-mgl-12v-22_1-1_2015_5f031f3e-6105-4e98-8fa1-31ff69de6b4a.jpeg?v=1443494981","width":500},{"alt":null,"id":25252888675,"position":2,"preview_image":{"aspect_ratio":0.879,"height":340,"width":299,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/dim251dfb345dec34_2015_b71378fb-4421-498d-a304-e8ade9b19803.png?v=1443494981"},"aspect_ratio":0.879,"height":340,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/dim251dfb345dec34_2015_b71378fb-4421-498d-a304-e8ade9b19803.png?v=1443494981","width":299},{"alt":null,"id":25252921443,"position":3,"preview_image":{"aspect_ratio":0.991,"height":351,"width":348,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/dim51dfb347ef6d6_2015_e9bfd9fd-fd73-4547-8bf9-eb87f37e085e.png?v=1443494981"},"aspect_ratio":0.991,"height":351,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/dim51dfb347ef6d6_2015_e9bfd9fd-fd73-4547-8bf9-eb87f37e085e.png?v=1443494981","width":348}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEasy to handle\u003c\/li\u003e\n\u003cli\u003eFire retardant casing\u003c\/li\u003e\n\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cli\u003eSplash resistant cover\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003eBL 983318 is a mini controller that has been designed for easy. affordable installation in tight spaces. ideal for simple yet effective process control.\u003c\/p\u003e\u003cp\u003eBL 983318 features ATC (Automatic Temperature Compensation) and simple one point calibration performed through the trimmer.\u003c\/p\u003e\u003cp\u003eThe multicolored LED continuously indicates if the controller is in measurement. dosing or alarm mode.\u003c\/p\u003e\u003cp\u003eWiring and external device connections are extremely simple to perform through the terminals on the rear of the instrument.\u003c\/p\u003e\u003cp\u003eUsers can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations. because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\u003cp\u003eThe overtime control system advises users when the relay is active too long. helping to prevent over-dosage.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eBL 983318-1 ( 115\/230V) are supplied with mounting brackets. transparent cover and instruction manual.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manBL_983318.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manBL_983318.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 ppt (0 to 10.000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 ppt (10 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7632-00 EC\/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. 5 to 50°C (41 to 122°F) with ß = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Relay\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected). 250 Vac. 30 VDC contact close when measure \u0026gt; set point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 10 ppt (10.000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertime\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable. typically from 5 to approx. 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSee Chart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e"}

TDS Mini Controller 0.0 to 10.00 g/L (ppt) - 230V

Product Description


  • Easy to handle
  • Fire retardant casing
  • Selectable overdose protection system
  • Splash resistant cover

 

BL 983318 is a mini controller that has been designed for easy. affordable installation in tight spaces. ideal for simple yet effective process control.

BL 983318 features ATC (Automatic Temperature Compensation) and simple one point calibration performed through the trimmer.

The multicolored LED continuously indicates if the controller is in measurement. dosing or alarm mode.

Wiring and external device connections are extremely simple to perform through the terminals on the rear of the instrument.

Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations. because it permits operators to enable or disable the dosing relay according to need.

The overtime control system advises users when the relay is active too long. helping to prevent over-dosage.

 

Order Information:
BL 983318-1 ( 115/230V) are supplied with mounting brackets. transparent cover and instruction manual.

Product Manuals

  Manual: Download

Specification :

Range   0.00 to 10.00 ppt (0 to 10.000 ppm)
Resolution   0.1 ppt (10 ppm)
Accuracy @ 25°C   ±2% F.S.
TDS Conversion Factor   0.5
Probe   HI 7632-00 EC/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included)
Temperature Compensation   Automatic. 5 to 50°C (41 to 122°F) with ß = 2%/°C
Calibration   manual. with CAL trimmer
Dosing Relay   maximum 2A (fuse protected). 250 Vac. 30 VDC contact close when measure > set point
Setpoint   adjustable from 0 to 10 ppt (10.000 ppm)
Overtime   adjustable. typically from 5 to approx. 30 minutes
Power Supply   See Chart
Dimensions   79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’)