Please email info@acornsci.com for orders during Covid-19 Alert Level 3.

{"id":6615190405219,"title":"HAIER BIOMEDICAL HR1200-IIA2","handle":"copy-of-haier-biomedical-hr1200-iia2","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eIntelligent series microbiological class II safety cabinet, provides protection for the user, sample and environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-v-34176663=\"\" class=\"tab-introduce-two\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"container\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv data-v-34176663=\"\" class=\"con\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"104\" width=\"104\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/8d3b91681a90ecf504722bba05f55a2b.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003ePatented Intelligent Constant Air Velocity Technology\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eIt provides real time monitoring of the air velocity of the working area, compares it with the standard air velocity to keep the air speed constant within the safety cabinet by adjustment of the fan speed via the microcomputer system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"116\" width=\"116\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/b458ed277e39a5a78b4e10e9ef75b2bc.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003e304 Stainless Steel\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eCurved worksurface ensures reduces chance of contamination and is easy to clean\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/c53158269bc46c260bc8c66eb55ea3cd.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eDigital Microprocessor Control System\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eReal time display of key parameters - downflow velocity, inflow velocity, airflow volume, static pressure, negative pressure, accumulative running time of fan and UV lamp and remaining life of filter. Visual and audible alarms and UV sterilization function.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/059ed624a3f43a61c1e33f98f2854c48.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eLow Noise Safety Energy-Saving Mode\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eWhich reduces noise, conserves energy and improves the service life of the filter. When the human body sensor module detects under the intelligent mode that the person is outside and away from the operating area for over 15 minutes, the microcomputer program will automatically switch the safety\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/5dbd4ef14f72ee2cf78bf90427645076.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eProfessional Air-Flow Distribution Module\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eThe safety cabinet provides a more uniform airflow, reduced contamination and noise to \u0026lt;62dB(A).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"121\" width=\"121\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/c941092a86d8a3d1bbb069481dca9122.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eUltra-Low Penetration Air Filter System\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eAmerican AAF (ULPA) filter is tested to a typical efficiency of \u0026gt; 99.9995% for 0.12 micron particles. ULPA filter provides vertical laminar flow to the worktable to protect samples from pollution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"122\" width=\"122\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/21cb8d17e4ce4c96bf21c4bf10f6d8f3.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003ePatented Air Flow Disruption Technology\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eUtilizes side air design on the upper edge and on both sides of the front window to eliminate ‘blind spots’. This prevents crossflow between inside and outside air, reducing contamination (Patent No. ZL200520125549.X).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"127\" width=\"127\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/e2b67b4d013f9f716ca66d4cd6030b68.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eUnique Drop-Down Front Glass Window\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eCan be removed in seconds to enable quick and efficient cleaning of upper sections, limiting downtime.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"118\" width=\"118\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/874c0e7f42c9dda0a975f1bd2041406e.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eRemovable Arm Rest\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eReduces user fatigue and does not interfere with air inflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"tab-introduce-threeadd\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"container\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Parameters\u003c\/h2\u003e\n\u003cdiv data-v-34176663=\"\" class=\"table-responsive\"\u003e\n\u003ctable data-v-34176663=\"\" class=\"table\"\u003e\n\u003cthead data-v-34176663=\"\"\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003cth data-v-34176663=\"\" colspan=\"2\"\u003eHR900-IIA2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-v-34176663=\"\"\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eWorking Voltage\u0026amp;Frequency(V\/Hz)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e220V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003ePower(VA)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003ePower of Blower(W)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eAC-L=330W,M=465W,H=735W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eAirflow Circulation\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e70% Downflow,30% Exhaust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eMain Filter Typical Efficiency\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eULPA ,U15,99.9995%@0.12um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eExhaust Filter Typical Efficiency\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e\u003cspan\u003eHEPA ,H14,99.995%@0.3um\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eExterior Dimension(W*D*H) (mm)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e1380*845*2160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eExterior Dimension(W*D*H) (in)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e54.3*33.3*85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-v-34176663=\"\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul data-v-34176663=\"\"\u003e\n\u003cli class=\"col-md-3 col-xs-6 item\" data-v-34176663=\"\"\u003e\n\u003cdiv class=\"con\" data-v-34176663=\"\"\u003e\n\u003cdiv class=\"con-img\" data-v-34176663=\"\"\u003e\u003cimg src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/4883874071bf0c93e3e60252d51cc31f.png\" data-v-34176663=\"\" width=\"289\" height=\"289\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"info\" data-v-34176663=\"\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eBiological Safety Cabinet HR900-IIA2\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eBiological Safety Cabinet\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"col-md-3 col-xs-6 item\" data-v-34176663=\"\"\u003e\n\u003cdiv class=\"con\" data-v-34176663=\"\"\u003e\n\u003cdiv class=\"con-img\" data-v-34176663=\"\"\u003e\u003cimg src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/199fcac25546762bbd295e80427feedd.png\" data-v-34176663=\"\" width=\"297\" height=\"297\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"info\" data-v-34176663=\"\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eBiological Safety Cabinet HR1500-IIA2\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eBiological Safety Cabinet\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2021-08-04T09:31:35+12:00","created_at":"2021-08-04T09:31:35+12:00","vendor":"Haier Biomedical","type":"Biosafety Cabinets","tags":["brand_Haier Medical","Category_Biosafety Cabinets","Length_1200mm","Manufacturer_Haier Biomedical","Type_Class 2 Biosafety Cabinets"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39506946457699,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"HAIER BIOMEDICAL HR1200-IIA2","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/13.png?v=1634688112"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/13.png?v=1634688112","options":["Title"],"media":[{"alt":null,"id":20924322054243,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2048,"width":2048,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/13.png?v=1634688112"},"aspect_ratio":1.0,"height":2048,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/13.png?v=1634688112","width":2048}],"content":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eIntelligent series microbiological class II safety cabinet, provides protection for the user, sample and environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-v-34176663=\"\" class=\"tab-introduce-two\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"container\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv data-v-34176663=\"\" class=\"con\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"104\" width=\"104\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/8d3b91681a90ecf504722bba05f55a2b.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003ePatented Intelligent Constant Air Velocity Technology\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eIt provides real time monitoring of the air velocity of the working area, compares it with the standard air velocity to keep the air speed constant within the safety cabinet by adjustment of the fan speed via the microcomputer system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"116\" width=\"116\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/b458ed277e39a5a78b4e10e9ef75b2bc.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003e304 Stainless Steel\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eCurved worksurface ensures reduces chance of contamination and is easy to clean\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/c53158269bc46c260bc8c66eb55ea3cd.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eDigital Microprocessor Control System\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eReal time display of key parameters - downflow velocity, inflow velocity, airflow volume, static pressure, negative pressure, accumulative running time of fan and UV lamp and remaining life of filter. Visual and audible alarms and UV sterilization function.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/059ed624a3f43a61c1e33f98f2854c48.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eLow Noise Safety Energy-Saving Mode\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eWhich reduces noise, conserves energy and improves the service life of the filter. When the human body sensor module detects under the intelligent mode that the person is outside and away from the operating area for over 15 minutes, the microcomputer program will automatically switch the safety\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/5dbd4ef14f72ee2cf78bf90427645076.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eProfessional Air-Flow Distribution Module\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eThe safety cabinet provides a more uniform airflow, reduced contamination and noise to \u0026lt;62dB(A).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"121\" width=\"121\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/c941092a86d8a3d1bbb069481dca9122.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eUltra-Low Penetration Air Filter System\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eAmerican AAF (ULPA) filter is tested to a typical efficiency of \u0026gt; 99.9995% for 0.12 micron particles. ULPA filter provides vertical laminar flow to the worktable to protect samples from pollution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"122\" width=\"122\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/21cb8d17e4ce4c96bf21c4bf10f6d8f3.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003ePatented Air Flow Disruption Technology\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eUtilizes side air design on the upper edge and on both sides of the front window to eliminate ‘blind spots’. This prevents crossflow between inside and outside air, reducing contamination (Patent No. ZL200520125549.X).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"127\" width=\"127\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/e2b67b4d013f9f716ca66d4cd6030b68.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eUnique Drop-Down Front Glass Window\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eCan be removed in seconds to enable quick and efficient cleaning of upper sections, limiting downtime.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"col-md-12 col-xs-12 item\"\u003e\n\u003cimg height=\"118\" width=\"118\" data-v-34176663=\"\" src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/874c0e7f42c9dda0a975f1bd2041406e.png\" class=\"list-left\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"list-right\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eRemovable Arm Rest\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eReduces user fatigue and does not interfere with air inflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-v-34176663=\"\" class=\"tab-introduce-threeadd\"\u003e\n\u003cdiv data-v-34176663=\"\" class=\"container\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Parameters\u003c\/h2\u003e\n\u003cdiv data-v-34176663=\"\" class=\"table-responsive\"\u003e\n\u003ctable data-v-34176663=\"\" class=\"table\"\u003e\n\u003cthead data-v-34176663=\"\"\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003cth data-v-34176663=\"\" colspan=\"2\"\u003eHR900-IIA2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-v-34176663=\"\"\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eWorking Voltage\u0026amp;Frequency(V\/Hz)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e220V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003ePower(VA)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003ePower of Blower(W)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eAC-L=330W,M=465W,H=735W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eAirflow Circulation\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e70% Downflow,30% Exhaust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eMain Filter Typical Efficiency\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eULPA ,U15,99.9995%@0.12um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eExhaust Filter Typical Efficiency\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e\u003cspan\u003eHEPA ,H14,99.995%@0.3um\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eExterior Dimension(W*D*H) (mm)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e1380*845*2160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-34176663=\"\"\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003eExterior Dimension(W*D*H) (in)\u003c\/td\u003e\n\u003ctd data-v-34176663=\"\" colspan=\"1\"\u003e54.3*33.3*85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-v-34176663=\"\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul data-v-34176663=\"\"\u003e\n\u003cli class=\"col-md-3 col-xs-6 item\" data-v-34176663=\"\"\u003e\n\u003cdiv class=\"con\" data-v-34176663=\"\"\u003e\n\u003cdiv class=\"con-img\" data-v-34176663=\"\"\u003e\u003cimg src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/4883874071bf0c93e3e60252d51cc31f.png\" data-v-34176663=\"\" width=\"289\" height=\"289\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"info\" data-v-34176663=\"\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eBiological Safety Cabinet HR900-IIA2\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eBiological Safety Cabinet\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"col-md-3 col-xs-6 item\" data-v-34176663=\"\"\u003e\n\u003cdiv class=\"con\" data-v-34176663=\"\"\u003e\n\u003cdiv class=\"con-img\" data-v-34176663=\"\"\u003e\u003cimg src=\"https:\/\/biomedical-test.oss-accelerate.aliyuncs.com\/image\/199fcac25546762bbd295e80427feedd.png\" data-v-34176663=\"\" width=\"297\" height=\"297\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"info\" data-v-34176663=\"\"\u003e\n\u003ch4 data-v-34176663=\"\"\u003eBiological Safety Cabinet HR1500-IIA2\u003c\/h4\u003e\n\u003cp data-v-34176663=\"\"\u003eBiological Safety Cabinet\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HAIER BIOMEDICAL HR1200-IIA2

Product Description

Intelligent series microbiological class II safety cabinet, provides protection for the user, sample and environment.

Product Features

Patented Intelligent Constant Air Velocity Technology

It provides real time monitoring of the air velocity of the working area, compares it with the standard air velocity to keep the air speed constant within the safety cabinet by adjustment of the fan speed via the microcomputer system.

304 Stainless Steel

Curved worksurface ensures reduces chance of contamination and is easy to clean

Digital Microprocessor Control System

Real time display of key parameters - downflow velocity, inflow velocity, airflow volume, static pressure, negative pressure, accumulative running time of fan and UV lamp and remaining life of filter. Visual and audible alarms and UV sterilization function.

Low Noise Safety Energy-Saving Mode

Which reduces noise, conserves energy and improves the service life of the filter. When the human body sensor module detects under the intelligent mode that the person is outside and away from the operating area for over 15 minutes, the microcomputer program will automatically switch the safety

Professional Air-Flow Distribution Module

The safety cabinet provides a more uniform airflow, reduced contamination and noise to <62dB(A).

Ultra-Low Penetration Air Filter System

American AAF (ULPA) filter is tested to a typical efficiency of > 99.9995% for 0.12 micron particles. ULPA filter provides vertical laminar flow to the worktable to protect samples from pollution.

Patented Air Flow Disruption Technology

Utilizes side air design on the upper edge and on both sides of the front window to eliminate ‘blind spots’. This prevents crossflow between inside and outside air, reducing contamination (Patent No. ZL200520125549.X).

Unique Drop-Down Front Glass Window

Can be removed in seconds to enable quick and efficient cleaning of upper sections, limiting downtime.

Removable Arm Rest

Reduces user fatigue and does not interfere with air inflow.

Product Parameters

HR900-IIA2
Working Voltage&Frequency(V/Hz) 220V 50Hz
Power(VA) 1500
Power of Blower(W) AC-L=330W,M=465W,H=735W
Airflow Circulation 70% Downflow,30% Exhaust
Main Filter Typical Efficiency ULPA ,U15,99.9995%@0.12um
Exhaust Filter Typical Efficiency HEPA ,H14,99.995%@0.3um
Exterior Dimension(W*D*H) (mm) 1380*845*2160
Exterior Dimension(W*D*H) (in) 54.3*33.3*85

Related Products

  • Biological Safety Cabinet HR900-IIA2

    Biological Safety Cabinet

  • Biological Safety Cabinet HR1500-IIA2

    Biological Safety Cabinet

This product is available upon request. Contact us for more information.