{"id":1582175301,"title":"HANNA HI 84530-02 Total Acidity Mini Titrator for Water Analysis","handle":"hi-84530-02","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eThe HI 84530 is an easy to use. fast and affordable mini automatic titrator with a pH meter designed for the rapid and accurate analysis of Total Titratable Acidity in water. It surpasses the HI 84430 to increase accuracy by improving the titrant delivery system and measuring ranges. The HI 84530 incorporates a precise piston dosing system. which allows for a highly accurate determination of the amount of titrant used. It is also capable of dynamic dosing. making testing both faster and more accurate. Pump calibrations. performed with the provided Hanna standards. help assure the accuracy of the measurement.\u003cbr\u003eAn intuitive interface makes the instrument simple to use and the dedicated HELP key guides the user through set-up.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 84530-01 (115V) and HI 84530-02 (230V) are supplied with an HI 1131B pH electrode. HI 7662-M temperature probe. HI 84530-70 Reagent Kit for Water Analysis. Two 100 mL Beakers. Tube set (aspiration tube with titrant bottle cap and dispensing tube with tip). Dosing Pump Valve. HI 740236 5 mL Syringe. 1 mL plastic pipette. stir bar. power adapter and instruction manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003eLow Range: 15.0 - 500.0 mg\/L (ppm) as CaCO3 meq\/L: 0.3 - 10.0 meq\/L as CaCO3 High Range: 400 - 4000 mg\/L (ppm) as CaCO3 meq\/L: 8 - 80 meq\/L as CaCO3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.01 meq\/L; 0.01 meq%; 0.1 mg\/L High Range: 0.1 meq\/L; 0.01 meq%; 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003e5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003eacid-base titration - total acidity (phenolphthalein) \/ strong acidity (Methyl Orange)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinciple\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003eendpoint titration : 8.30 pH \/ 3.7 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Speed\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003e0.5 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirring Speed\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003e600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Data\u003c\/td\u003e\n\u003ctd\u003eTitrator\u003c\/td\u003e\n\u003ctd\u003eup to 200 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH \/ -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003e.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003e1. 2 or 3 calibration points; 3 available buffers (1.68. 4.01; 8.30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20 to 120°C (-4 to 248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Data\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003eUp to 200 samples (combined samples for pH and mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003emV Meter\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003emV Meter\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003emV Meter\u003c\/td\u003e\n\u003ctd\u003e± 1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogged Data\u003c\/td\u003e\n\u003ctd\u003emV Meter\u003c\/td\u003e\n\u003ctd\u003eUp to 200 samples (pH or mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.4°C without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:09:31+12:00","created_at":"2015-09-01T15:16:54+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Titrators"],"price":159000,"price_min":159000,"price_max":159000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857312005,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI 84530-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 84530-02 Total Acidity Mini Titrator for Water Analysis","public_title":null,"options":["Default Title"],"price":159000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi_84530_display_sized_2015.jpeg?v=1443495741"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi_84530_display_sized_2015.jpeg?v=1443495741","options":["Title"],"media":[{"alt":"HANNA HI 84530-02 Total Acidity Mini Titrator for Water Analysis - Acorn Scientific","id":21303361635,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi_84530_display_sized_2015.jpeg?v=1443495741"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi_84530_display_sized_2015.jpeg?v=1443495741","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eThe HI 84530 is an easy to use. fast and affordable mini automatic titrator with a pH meter designed for the rapid and accurate analysis of Total Titratable Acidity in water. It surpasses the HI 84430 to increase accuracy by improving the titrant delivery system and measuring ranges. The HI 84530 incorporates a precise piston dosing system. which allows for a highly accurate determination of the amount of titrant used. It is also capable of dynamic dosing. making testing both faster and more accurate. Pump calibrations. performed with the provided Hanna standards. help assure the accuracy of the measurement.\u003cbr\u003eAn intuitive interface makes the instrument simple to use and the dedicated HELP key guides the user through set-up.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 84530-01 (115V) and HI 84530-02 (230V) are supplied with an HI 1131B pH electrode. HI 7662-M temperature probe. HI 84530-70 Reagent Kit for Water Analysis. Two 100 mL Beakers. Tube set (aspiration tube with titrant bottle cap and dispensing tube with tip). Dosing Pump Valve. HI 740236 5 mL Syringe. 1 mL plastic pipette. stir bar. power adapter and instruction manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003eLow Range: 15.0 - 500.0 mg\/L (ppm) as CaCO3 meq\/L: 0.3 - 10.0 meq\/L as CaCO3 High Range: 400 - 4000 mg\/L (ppm) as CaCO3 meq\/L: 8 - 80 meq\/L as CaCO3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.01 meq\/L; 0.01 meq%; 0.1 mg\/L High Range: 0.1 meq\/L; 0.01 meq%; 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003e5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003eacid-base titration - total acidity (phenolphthalein) \/ strong acidity (Methyl Orange)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinciple\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003eendpoint titration : 8.30 pH \/ 3.7 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Speed\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003e0.5 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirring Speed\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003ctd\u003e600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Data\u003c\/td\u003e\n\u003ctd\u003eTitrator\u003c\/td\u003e\n\u003ctd\u003eup to 200 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH \/ -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003e.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003e1. 2 or 3 calibration points; 3 available buffers (1.68. 4.01; 8.30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20 to 120°C (-4 to 248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Data\u003c\/td\u003e\n\u003ctd\u003epH Meter\u003c\/td\u003e\n\u003ctd\u003eUp to 200 samples (combined samples for pH and mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003emV Meter\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003emV Meter\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003emV Meter\u003c\/td\u003e\n\u003ctd\u003e± 1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogged Data\u003c\/td\u003e\n\u003ctd\u003emV Meter\u003c\/td\u003e\n\u003ctd\u003eUp to 200 samples (pH or mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.4°C without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 84530-02 Total Acidity Mini Titrator for Water Analysis

Product Description

 

The HI 84530 is an easy to use. fast and affordable mini automatic titrator with a pH meter designed for the rapid and accurate analysis of Total Titratable Acidity in water. It surpasses the HI 84430 to increase accuracy by improving the titrant delivery system and measuring ranges. The HI 84530 incorporates a precise piston dosing system. which allows for a highly accurate determination of the amount of titrant used. It is also capable of dynamic dosing. making testing both faster and more accurate. Pump calibrations. performed with the provided Hanna standards. help assure the accuracy of the measurement.
An intuitive interface makes the instrument simple to use and the dedicated HELP key guides the user through set-up.

 

 

 

Order Information:
HI 84530-01 (115V) and HI 84530-02 (230V) are supplied with an HI 1131B pH electrode. HI 7662-M temperature probe. HI 84530-70 Reagent Kit for Water Analysis. Two 100 mL Beakers. Tube set (aspiration tube with titrant bottle cap and dispensing tube with tip). Dosing Pump Valve. HI 740236 5 mL Syringe. 1 mL plastic pipette. stir bar. power adapter and instruction manual.

SPECIFICATIONS:

Range Titration Low Range: 15.0 - 500.0 mg/L (ppm) as CaCO3 meq/L: 0.3 - 10.0 meq/L as CaCO3 High Range: 400 - 4000 mg/L (ppm) as CaCO3 meq/L: 8 - 80 meq/L as CaCO3
Resolution Titration Low Range: 0.01 meq/L; 0.01 meq%; 0.1 mg/L High Range: 0.1 meq/L; 0.01 meq%; 1 mg/L
Accuracy (@25ºC/77ºF) Titration 5% of reading
Method Titration acid-base titration - total acidity (phenolphthalein) / strong acidity (Methyl Orange)
Principle Titration endpoint titration : 8.30 pH / 3.7 pH
Pump Speed Titration 0.5 mL/min
Stirring Speed Titration 600 rpm
Logging Data Titrator up to 200 samples
Range pH Meter -2.0 to 16.0 pH / -2.00 to 16.00 pH
Resolution pH Meter .1 pH / 0.01 pH
Accuracy (@25ºC/77ºF) pH Meter ±0.01 pH
Calibration pH Meter 1. 2 or 3 calibration points; 3 available buffers (1.68. 4.01; 8.30)
Temperature Compensation pH Meter manual or automatic from -20 to 120°C (-4 to 248°F)
Logging Data pH Meter Up to 200 samples (combined samples for pH and mV)
Range mV Meter -2000.0 to 2000.0 mV
Resolution mV Meter 0.1 mV
Accuracy mV Meter ± 1.0 mV
Logged Data mV Meter Up to 200 samples (pH or mV)
Range Temperature -20.0 to 120.0°C (-4.0 to 248.0°F)
Resolution Temperature 0.1°C
Accuracy Temperature ±0.4°C without probe error
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply   12 VDC adapter (included)
Dimensions   235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)
Weight   1.9 kg (67.0 oz.)