Email info@acornsci.com for orders and inquiries.

{"id":1582112581,"title":"HANNA HI 9146-04 Dissolved Oxygen \/ °C - Meter (0 to 45 mg\/L)","handle":"hi-9146-04","description":"\u003cul\u003e\n\u003cli\u003eOn-screen tutorial messages\u003c\/li\u003e\n\u003cli\u003eTwo point calibration\u003c\/li\u003e\n\u003cli\u003eAuto endpoint\u003c\/li\u003e\n\u003cli\u003eDO range up to 300%. temperature compensated\u003c\/li\u003e\n\u003cli\u003eAltitude compensation up to 4000 m\u003c\/li\u003e\n\u003cli\u003eSalinity compensation up to 80 g\/L\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration in air\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003eLow battery indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 9146 is a water-resistant. dissolved oxygen meter that measures up to 300% saturation or 45 ppm (mg\/L) with temperature compensation and automatic calibration. It has been developed for DO and temperature measurement in water. wastewater. wine and applications such as fish farming.\u003c\/p\u003e\n\u003cp\u003eThis instrument also allows altitude compensation up to 4000 m and the ppm and % saturation are both compensated for changes in solubility of oxygen in water and for permeability of the membrane as well as the temperature effect.\u003c\/p\u003e\n\u003cp\u003eThe included polarographic probe features built-in temperature compensation and removable protective membrane cover.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 9146-04 is supplied complete with HI 76407\/4F probe with 4 m (13.1’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case. HI 9146-10 is supplied complete with HI 76407\/10F probe with 10 m (32.8’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. in air. at 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 1900 m (100 m 326' resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L (1g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76407\/4F with 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4 x 1.5 AA batteries \/ approx. 200 hours of continuous use; auto-off after 4 hours of inactivity; or input for 12 Vdc power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e196 x 80 x 60 mm (7.7 x 3.1 x 2.4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 g (1.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T16:23:21+12:00","created_at":"2015-09-01T15:09:18+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Dissolved Oxygen"],"price":106050,"price_min":106050,"price_max":106050,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857192837,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI 9146-04","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 9146-04 Dissolved Oxygen \/ °C - Meter (0 to 45 mg\/L)","public_title":null,"options":["Default Title"],"price":106050,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/sauerstoff-handmessgerat-mit-4-m-kabel-sonde-1080_1-151e139489ab9a_2015.jpeg?v=1443495076"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/sauerstoff-handmessgerat-mit-4-m-kabel-sonde-1080_1-151e139489ab9a_2015.jpeg?v=1443495076","options":["Title"],"media":[{"alt":"HANNA HI 9146-04 Dissolved Oxygen \/ °C - Meter (0 to 45 mg\/L) - Acorn Scientific","id":21282160739,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/sauerstoff-handmessgerat-mit-4-m-kabel-sonde-1080_1-151e139489ab9a_2015.jpeg?v=1443495076"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/sauerstoff-handmessgerat-mit-4-m-kabel-sonde-1080_1-151e139489ab9a_2015.jpeg?v=1443495076","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli\u003eOn-screen tutorial messages\u003c\/li\u003e\n\u003cli\u003eTwo point calibration\u003c\/li\u003e\n\u003cli\u003eAuto endpoint\u003c\/li\u003e\n\u003cli\u003eDO range up to 300%. temperature compensated\u003c\/li\u003e\n\u003cli\u003eAltitude compensation up to 4000 m\u003c\/li\u003e\n\u003cli\u003eSalinity compensation up to 80 g\/L\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration in air\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003eLow battery indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 9146 is a water-resistant. dissolved oxygen meter that measures up to 300% saturation or 45 ppm (mg\/L) with temperature compensation and automatic calibration. It has been developed for DO and temperature measurement in water. wastewater. wine and applications such as fish farming.\u003c\/p\u003e\n\u003cp\u003eThis instrument also allows altitude compensation up to 4000 m and the ppm and % saturation are both compensated for changes in solubility of oxygen in water and for permeability of the membrane as well as the temperature effect.\u003c\/p\u003e\n\u003cp\u003eThe included polarographic probe features built-in temperature compensation and removable protective membrane cover.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 9146-04 is supplied complete with HI 76407\/4F probe with 4 m (13.1’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case. HI 9146-10 is supplied complete with HI 76407\/10F probe with 10 m (32.8’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. in air. at 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 1900 m (100 m 326' resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L (1g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76407\/4F with 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4 x 1.5 AA batteries \/ approx. 200 hours of continuous use; auto-off after 4 hours of inactivity; or input for 12 Vdc power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e196 x 80 x 60 mm (7.7 x 3.1 x 2.4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 g (1.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}

HANNA HI 9146-04 Dissolved Oxygen / °C - Meter (0 to 45 mg/L)

Product Description
  • On-screen tutorial messages
  • Two point calibration
  • Auto endpoint
  • DO range up to 300%. temperature compensated
  • Altitude compensation up to 4000 m
  • Salinity compensation up to 80 g/L
  • Automatic calibration in air
  • GLP features
  • Low battery indicator

 

HI 9146 is a water-resistant. dissolved oxygen meter that measures up to 300% saturation or 45 ppm (mg/L) with temperature compensation and automatic calibration. It has been developed for DO and temperature measurement in water. wastewater. wine and applications such as fish farming.

This instrument also allows altitude compensation up to 4000 m and the ppm and % saturation are both compensated for changes in solubility of oxygen in water and for permeability of the membrane as well as the temperature effect.

The included polarographic probe features built-in temperature compensation and removable protective membrane cover.

 

 

Order Information:   HI 9146-04 is supplied complete with HI 76407/4F probe with 4 m (13.1’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case. HI 9146-10 is supplied complete with HI 76407/10F probe with 10 m (32.8’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case.

Specification :

Range O2 0.00 to 45.00 mg/L
Range % Saturation O2 0.0 to 300.0%
Range Temperature 0.0 to 50.0°C
Resolution O2 0.01 mg/L
Resolution % Saturation O2 0.1%
Resolution Temperature 0.1°C
Accuracy O2 ±1.5% F.S.
Accuracy % Saturation O2 ±1.5% F.S.
Accuracy Temperature 0.5°C
Calibration   automatic. in air. at 100%
Temperature Compensation   automatic. 0 to 50°C (32 to 122°F)
Altitude Compensation   0 to 1900 m (100 m 326' resolution)
Salinity Compensation   0 to 40 g/L (1g/L resolution)
Probe   HI 76407/4F with 4 m cable
Power Supply   4 x 1.5 AA batteries / approx. 200 hours of continuous use; auto-off after 4 hours of inactivity; or input for 12 Vdc power adapter
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   196 x 80 x 60 mm (7.7 x 3.1 x 2.4")
Weight   500 g (1.1 lb.)

 

This product is available upon request. Contact us for more information.