Email info@acornsci.com for orders and inquiries.

{"id":1582177157,"title":"HANNA HI 991401-02 Gro'Chek pH and Temperature Monitor","handle":"hi-991401-02","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eWaterproof\u003c\/li\u003e\n\u003cli\u003eMeasure in °C or °F\u003c\/li\u003e\n\u003cli\u003eStability indicator\u003c\/li\u003e\n\u003cli\u003eHOLD function\u003c\/li\u003e\n\u003cli\u003e\u003cspan id=\"c2d815px2_2\" class=\"c2d815px2\"\u003eBacklit display\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis indicator from HANNA has a large backlit LCD to give users instantaneous readings of both pH and temperature that can be easily read in dim light. The HI 991401-01 provides automatic calibration. automatic buffer selection and automatic \u003cspan id=\"c2d815px2_1\" class=\"c2d815px2\"\u003etemperature compensation\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eHI 991401-01's waterproof housing has been designed to meet the growers’ need for an indictor that is well suited to withstand the aggressive environments found in agricultural and hydroponics applications. Measurements are highly accurate and can be verified with one or two point calibrations. With a 12 VDC \u003cspan id=\"c2d815px2_3\" class=\"c2d815px2\"\u003epower supply\u003c\/span\u003e included with the meter. low battery failures are never an issue.\u003c\/p\u003e\n\u003cp\u003eThe pH electrode has been specially designed to address the needs of growers. It’s design guarantees greater clogging resistance in fertilizer solutions with high concentrations of phosphate. nitrate. etc. to ensure longer electrode life.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 991401-01 (115V) and HI 991401-02 (230V) are supplied with HI 1293D pH electrode. HI 1294 temperature probe (fixed). HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. 12 VDC power adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C (32 to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (±1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1293D PEI body. pre-amplified pH electrode with 1\/2” NPT pipe thread. DIN connector and 2 m (6.6’) cable (included); HI 1294 temperature probe with 1.2” NPT pipe thread and 2 m (6.6’) cable (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 or 2 points with 2 sets of memorized buffers\u003cbr\u003e(pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 Vdc power adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e160 x 105 x 31 mm (6.3 x 4.1 x 1.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e190 g (6.7 oz.) - meter only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:09:24+12:00","created_at":"2015-09-01T15:17:12+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":21150,"price_min":21150,"price_max":21150,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857315909,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI 991401-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 991401-02 Gro'Chek pH and Temperature Monitor","public_title":null,"options":["Default Title"],"price":21150,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi991401-200_2015.jpeg?v=1443495760"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi991401-200_2015.jpeg?v=1443495760","options":["Title"],"media":[{"alt":null,"id":21304148067,"position":1,"preview_image":{"aspect_ratio":0.922,"height":217,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi991401-200_2015.jpeg?v=1443495760"},"aspect_ratio":0.922,"height":217,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi991401-200_2015.jpeg?v=1443495760","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eWaterproof\u003c\/li\u003e\n\u003cli\u003eMeasure in °C or °F\u003c\/li\u003e\n\u003cli\u003eStability indicator\u003c\/li\u003e\n\u003cli\u003eHOLD function\u003c\/li\u003e\n\u003cli\u003e\u003cspan id=\"c2d815px2_2\" class=\"c2d815px2\"\u003eBacklit display\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis indicator from HANNA has a large backlit LCD to give users instantaneous readings of both pH and temperature that can be easily read in dim light. The HI 991401-01 provides automatic calibration. automatic buffer selection and automatic \u003cspan id=\"c2d815px2_1\" class=\"c2d815px2\"\u003etemperature compensation\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eHI 991401-01's waterproof housing has been designed to meet the growers’ need for an indictor that is well suited to withstand the aggressive environments found in agricultural and hydroponics applications. Measurements are highly accurate and can be verified with one or two point calibrations. With a 12 VDC \u003cspan id=\"c2d815px2_3\" class=\"c2d815px2\"\u003epower supply\u003c\/span\u003e included with the meter. low battery failures are never an issue.\u003c\/p\u003e\n\u003cp\u003eThe pH electrode has been specially designed to address the needs of growers. It’s design guarantees greater clogging resistance in fertilizer solutions with high concentrations of phosphate. nitrate. etc. to ensure longer electrode life.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 991401-01 (115V) and HI 991401-02 (230V) are supplied with HI 1293D pH electrode. HI 1294 temperature probe (fixed). HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. 12 VDC power adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C (32 to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (±1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1293D PEI body. pre-amplified pH electrode with 1\/2” NPT pipe thread. DIN connector and 2 m (6.6’) cable (included); HI 1294 temperature probe with 1.2” NPT pipe thread and 2 m (6.6’) cable (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 or 2 points with 2 sets of memorized buffers\u003cbr\u003e(pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 Vdc power adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e160 x 105 x 31 mm (6.3 x 4.1 x 1.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e190 g (6.7 oz.) - meter only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 991401-02 Gro'Chek pH and Temperature Monitor

Product Description

 

  • Waterproof
  • Measure in °C or °F
  • Stability indicator
  • HOLD function
  • Backlit display

 

This indicator from HANNA has a large backlit LCD to give users instantaneous readings of both pH and temperature that can be easily read in dim light. The HI 991401-01 provides automatic calibration. automatic buffer selection and automatic temperature compensation.

HI 991401-01's waterproof housing has been designed to meet the growers’ need for an indictor that is well suited to withstand the aggressive environments found in agricultural and hydroponics applications. Measurements are highly accurate and can be verified with one or two point calibrations. With a 12 VDC power supply included with the meter. low battery failures are never an issue.

The pH electrode has been specially designed to address the needs of growers. It’s design guarantees greater clogging resistance in fertilizer solutions with high concentrations of phosphate. nitrate. etc. to ensure longer electrode life.

 

 

 

 

Order Information:
HI 991401-01 (115V) and HI 991401-02 (230V) are supplied with HI 1293D pH electrode. HI 1294 temperature probe (fixed). HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. 12 VDC power adapter and instructions.

SPECIFICATIONS:

Range pH 0.0 to 14.0 pH
  Temperature 0.0 to 60.0°C (32 to 140°F)
Resolution pH 0.1 pH
  Temperature 0.1°C (0.1°F)
Accuracy pH ±0.1 pH
  Temperature ±0.5°C (±1°F)
Probes   HI 1293D PEI body. pre-amplified pH electrode with 1/2” NPT pipe thread. DIN connector and 2 m (6.6’) cable (included); HI 1294 temperature probe with 1.2” NPT pipe thread and 2 m (6.6’) cable (fixed)
pH Calibration   automatic. 1 or 2 points with 2 sets of memorized buffers
(pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
Temperature Compensation   Automatic
Input Impedance   1012 Ohm
Power Supply   12 Vdc power adapter (included)
Environment   0 to 50°C (32 to 122°F); RH max 95%
Dimensions   160 x 105 x 31 mm (6.3 x 4.1 x 1.2)
Weight   190 g (6.7 oz.) - meter only

This product is available upon request. Contact us for more information.