Email info@acornsci.com for orders and inquiries.

{"id":1582172037,"title":"HANNA HI 122 pH\/ORP\/Temperature Meter with Built-in Printer","handle":"hi122-02","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003epH Calibration Check™\u003c\/li\u003e\n\u003cli\u003eElectrode response time\u003c\/li\u003e\n\u003cli\u003eFive pH calibration points\u003c\/li\u003e\n\u003cli\u003eSeven standard and two custom buffers\u003c\/li\u003e\n\u003cli\u003eOut of calibration range warning\u003c\/li\u003e\n\u003cli\u003eLarge. custom LCD\u003c\/li\u003e\n\u003cli\u003eBuilt-in \u003cspan id=\"be1m3_2\" class=\"be1m3\"\u003eimpact printer\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAutomatic data logging of 2000 records and log on demand\u003c\/li\u003e\n\u003cli\u003eGLP capabilities\u003c\/li\u003e\n\u003cli\u003eHigh and low audible alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 122 is a benchtop instrument featuring a built-in printer. Calibration Check™. electrode response time and \u003cspan id=\"be1m3_3\" class=\"be1m3\"\u003econdition monitoring\u003c\/span\u003e. and enhanced diagnostic messages during calibration.\u003c\/p\u003e\n\u003cp\u003eThis meter uses HANNA’s “P” series of electrodes. For more accuracy. these meters also check if the measurement is outside the calibration range and warns the user in case measurements are too far outside the calibration points. Calibration can be performed in up to five points using the standard seven buffers that are automatically recognized. or by using two custom buffer values. The buffer(s) used during calibration are displayed on the LCD even when in measurement mode.\u003c\/p\u003e\n\u003cp\u003eUsers can log on demand up to 50 samples (50 samples per channel for dual channel model). These meters have automatic data logging of up to 1000 points (1000 points per channel for dual channel model) with flexible starting and stopping criteria.\u003c\/p\u003e\n\u003cp\u003eThis instrument provides GLP capabilities that allows for the \u003cspan id=\"be1m3_1\" class=\"be1m3\"\u003estorage and retrieval\u003c\/span\u003e of all data regarding pH. rel mV. EC and NaCl calibration as well as data regarding the maintenance and status of the electrode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrinting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe built-in impact printer incorporated into the HI 122 uses regular paper that does not fade with time. A complete set of information based on the measured. set or recorded data can be printed on demand (for current reading in measurement mode. GLP and SETUP modes) or automatically (for autolog and log on demand modes). These models also allow users to print detailed information in four languages for specific help screens and instrument set-up.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 122-01 (115V) and HI 122-02 (230V) are supplied with HI 1131P pH electrode. HI 7662-T temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 7071S electrolyte solution (30 mL). (5) paper rolls. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cspan id=\"_mce_caret\" data-mce-bogus=\"true\" style=\"\"\u003e\u003cstrong\u003e?SPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH; -2.000 to 16.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003ctd\u003e±999.9 mV; ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0ºC (-4.0 to 248.0ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003ctd\u003e0.1 mV \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH \/ ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±699.9 mV) \/ ±0.5 mV (±999.9 mV) \/ ±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.4°C (±0.7ºF) excluding probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBNC Inputs\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 for pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Check\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStatus of electrode condition and response time\u003cbr\u003estatus of the buffer solutions during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV\u003cbr\u003eOffset Range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. up to 5 points with 7 memorized values (1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + 2 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual. -20.0 to 120°C (-4 to 248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1131P. glass body. refillable. BNC + pin connectors. 1 m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7662-T with 1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog-On-Demand\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Logging\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1000 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRS232 serial port. opto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ebuilt-in dot matrix printer. with 44 mm plain paper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 Vdc adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e280 x 203 x 84 mm (11.0 x 8.0 x 3.3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.9 kg (4.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e?ACCESSORIES:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201043P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201043P\"\u003eHI 1043P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination pH Electrode. Refillable w\/ Double Junction\u003cbr\u003e\u003csmall\u003eBNC Connection + pin\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201053P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201053P\"\u003eHI 1053P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination pH Electrode. Refillable w\/ Conical Tip\u003cbr\u003e\u003csmall\u003eBNC + pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201083P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201083P\"\u003eHI 1083P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination pH Electrode w\/ Micro Bulb\u003cbr\u003e\u003csmall\u003eBNC + pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201131P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201131P\"\u003eHI 1131P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefillable. Combination pH Electrode for the Laboratory and Beer Testing\u003cbr\u003e\u003csmall\u003eBNC + pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207662-T\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207662-T\"\u003eHI 7662-T\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205004L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205004L\"\u003eHI 5004L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 4.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205007L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205007L\"\u003eHI 5007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 7.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205010L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205010L\"\u003eHI 5010L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 10.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207061L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207061L\"\u003eHI 7061L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Cleaning Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070300L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207071\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207071\"\u003eHI 7071\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution. 3.5M KCl + AgCl\u003cbr\u003e4 x 30 mL bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207072\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207072\"\u003eHI 7072\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution. 1M KNO\u003csub\u003e³\u003c\/sub\u003e\u003cbr\u003e4 x 30 mL bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207082\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207082\"\u003eHI 7082\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution. 3.5M KCl\u003cbr\u003e4 x 30 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20710032\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20710032\"\u003eHI 710032\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePaper for Built-in Printers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20710033\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20710033\"\u003eHI 710033\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eInk Cartridge for Built-in Printers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2076405\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2076405\"\u003eHI 76405\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Holder with Steel Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2092000\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20920010\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20920010\"\u003eHI 920010\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCable for PC Connection. 9 to 9-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e","published_at":"2026-06-25T16:09:43+12:00","created_at":"2015-09-01T15:16:32+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":184000,"price_min":184000,"price_max":184000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857305349,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI122-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 122 pH\/ORP\/Temperature Meter with Built-in Printer","public_title":null,"options":["Default Title"],"price":184000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi123_200_2015.jpeg?v=1465536379"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi123_200_2015.jpeg?v=1465536379","options":["Title"],"media":[{"alt":"HI 122 pH\/ORP\/Temperature Meter with Built-in Printer - Acorn Scientific","id":21302444131,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi123_200_2015.jpeg?v=1465536379"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi123_200_2015.jpeg?v=1465536379","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003epH Calibration Check™\u003c\/li\u003e\n\u003cli\u003eElectrode response time\u003c\/li\u003e\n\u003cli\u003eFive pH calibration points\u003c\/li\u003e\n\u003cli\u003eSeven standard and two custom buffers\u003c\/li\u003e\n\u003cli\u003eOut of calibration range warning\u003c\/li\u003e\n\u003cli\u003eLarge. custom LCD\u003c\/li\u003e\n\u003cli\u003eBuilt-in \u003cspan id=\"be1m3_2\" class=\"be1m3\"\u003eimpact printer\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAutomatic data logging of 2000 records and log on demand\u003c\/li\u003e\n\u003cli\u003eGLP capabilities\u003c\/li\u003e\n\u003cli\u003eHigh and low audible alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 122 is a benchtop instrument featuring a built-in printer. Calibration Check™. electrode response time and \u003cspan id=\"be1m3_3\" class=\"be1m3\"\u003econdition monitoring\u003c\/span\u003e. and enhanced diagnostic messages during calibration.\u003c\/p\u003e\n\u003cp\u003eThis meter uses HANNA’s “P” series of electrodes. For more accuracy. these meters also check if the measurement is outside the calibration range and warns the user in case measurements are too far outside the calibration points. Calibration can be performed in up to five points using the standard seven buffers that are automatically recognized. or by using two custom buffer values. The buffer(s) used during calibration are displayed on the LCD even when in measurement mode.\u003c\/p\u003e\n\u003cp\u003eUsers can log on demand up to 50 samples (50 samples per channel for dual channel model). These meters have automatic data logging of up to 1000 points (1000 points per channel for dual channel model) with flexible starting and stopping criteria.\u003c\/p\u003e\n\u003cp\u003eThis instrument provides GLP capabilities that allows for the \u003cspan id=\"be1m3_1\" class=\"be1m3\"\u003estorage and retrieval\u003c\/span\u003e of all data regarding pH. rel mV. EC and NaCl calibration as well as data regarding the maintenance and status of the electrode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrinting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe built-in impact printer incorporated into the HI 122 uses regular paper that does not fade with time. A complete set of information based on the measured. set or recorded data can be printed on demand (for current reading in measurement mode. GLP and SETUP modes) or automatically (for autolog and log on demand modes). These models also allow users to print detailed information in four languages for specific help screens and instrument set-up.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 122-01 (115V) and HI 122-02 (230V) are supplied with HI 1131P pH electrode. HI 7662-T temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 7071S electrolyte solution (30 mL). (5) paper rolls. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cspan id=\"_mce_caret\" data-mce-bogus=\"true\" style=\"\"\u003e\u003cstrong\u003e?SPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH; -2.000 to 16.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003ctd\u003e±999.9 mV; ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0ºC (-4.0 to 248.0ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003ctd\u003e0.1 mV \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH \/ ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±699.9 mV) \/ ±0.5 mV (±999.9 mV) \/ ±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.4°C (±0.7ºF) excluding probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBNC Inputs\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 for pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Check\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStatus of electrode condition and response time\u003cbr\u003estatus of the buffer solutions during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV\u003cbr\u003eOffset Range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. up to 5 points with 7 memorized values (1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + 2 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual. -20.0 to 120°C (-4 to 248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1131P. glass body. refillable. BNC + pin connectors. 1 m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7662-T with 1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog-On-Demand\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Logging\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1000 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRS232 serial port. opto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ebuilt-in dot matrix printer. with 44 mm plain paper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 Vdc adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e280 x 203 x 84 mm (11.0 x 8.0 x 3.3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.9 kg (4.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e?ACCESSORIES:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201043P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201043P\"\u003eHI 1043P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination pH Electrode. Refillable w\/ Double Junction\u003cbr\u003e\u003csmall\u003eBNC Connection + pin\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201053P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201053P\"\u003eHI 1053P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination pH Electrode. Refillable w\/ Conical Tip\u003cbr\u003e\u003csmall\u003eBNC + pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201083P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201083P\"\u003eHI 1083P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination pH Electrode w\/ Micro Bulb\u003cbr\u003e\u003csmall\u003eBNC + pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201131P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201131P\"\u003eHI 1131P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefillable. Combination pH Electrode for the Laboratory and Beer Testing\u003cbr\u003e\u003csmall\u003eBNC + pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207662-T\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207662-T\"\u003eHI 7662-T\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205004L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205004L\"\u003eHI 5004L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 4.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205007L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205007L\"\u003eHI 5007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 7.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205010L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205010L\"\u003eHI 5010L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 10.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207061L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207061L\"\u003eHI 7061L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Cleaning Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070300L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207071\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207071\"\u003eHI 7071\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution. 3.5M KCl + AgCl\u003cbr\u003e4 x 30 mL bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207072\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207072\"\u003eHI 7072\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution. 1M KNO\u003csub\u003e³\u003c\/sub\u003e\u003cbr\u003e4 x 30 mL bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207082\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207082\"\u003eHI 7082\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution. 3.5M KCl\u003cbr\u003e4 x 30 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20710032\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20710032\"\u003eHI 710032\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePaper for Built-in Printers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20710033\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20710033\"\u003eHI 710033\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eInk Cartridge for Built-in Printers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2076405\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2076405\"\u003eHI 76405\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Holder with Steel Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2092000\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20920010\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20920010\"\u003eHI 920010\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCable for PC Connection. 9 to 9-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e"}

HANNA HI 122 pH/ORP/Temperature Meter with Built-in Printer

Product Description


  • pH Calibration Check™
  • Electrode response time
  • Five pH calibration points
  • Seven standard and two custom buffers
  • Out of calibration range warning
  • Large. custom LCD
  • Built-in impact printer
  • Automatic data logging of 2000 records and log on demand
  • GLP capabilities
  • High and low audible alarms

 

HI 122 is a benchtop instrument featuring a built-in printer. Calibration Check™. electrode response time and condition monitoring. and enhanced diagnostic messages during calibration.

This meter uses HANNA’s “P” series of electrodes. For more accuracy. these meters also check if the measurement is outside the calibration range and warns the user in case measurements are too far outside the calibration points. Calibration can be performed in up to five points using the standard seven buffers that are automatically recognized. or by using two custom buffer values. The buffer(s) used during calibration are displayed on the LCD even when in measurement mode.

Users can log on demand up to 50 samples (50 samples per channel for dual channel model). These meters have automatic data logging of up to 1000 points (1000 points per channel for dual channel model) with flexible starting and stopping criteria.

This instrument provides GLP capabilities that allows for the storage and retrieval of all data regarding pH. rel mV. EC and NaCl calibration as well as data regarding the maintenance and status of the electrode.

Printing

The built-in impact printer incorporated into the HI 122 uses regular paper that does not fade with time. A complete set of information based on the measured. set or recorded data can be printed on demand (for current reading in measurement mode. GLP and SETUP modes) or automatically (for autolog and log on demand modes). These models also allow users to print detailed information in four languages for specific help screens and instrument set-up.

 

Order Information:
HI 122-01 (115V) and HI 122-02 (230V) are supplied with HI 1131P pH electrode. HI 7662-T temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 7071S electrolyte solution (30 mL). (5) paper rolls. 12 VDC adapter and instructions.

?SPECIFICATIONS:

Range pH -2.00 to 16.00 pH; -2.000 to 16.000 pH
  ORP ±999.9 mV; ±2000 mV
  Temperature -20.0 to 120.0ºC (-4.0 to 248.0ºF)
Resolution pH 0.01 pH / 0.001 pH
  ORP 0.1 mV / 1 mV
  Temperature 0.1°C (0.1ºF)
Accuracy pH ±0.01 pH / ±0.002 pH
  ORP ±0.2 mV (±699.9 mV) / ±0.5 mV (±999.9 mV) / ±1 mV (±2000 mV)
  Temperature ±0.4°C (±0.7ºF) excluding probe error
BNC Inputs   1 for pH electrode
Calibration Check   Status of electrode condition and response time
status of the buffer solutions during calibration
Relative mV
Offset Range
  ±2000 mV
pH Calibration   automatic. up to 5 points with 7 memorized values (1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + 2 custom buffers
Temperature Compensation   Automatic or manual. -20.0 to 120°C (-4 to 248°F)
pH Electrode   HI 1131P. glass body. refillable. BNC + pin connectors. 1 m cable (included)
Temperature Probe   HI 7662-T with 1 m (3.3') cable (included)
Input Impedance   1012 Ohm
Log-On-Demand   50 samples
Automatic Logging   1000 samples
PC Connection   RS232 serial port. opto-isolated
Printer   built-in dot matrix printer. with 44 mm plain paper
Power Supply   12 Vdc adapter (included)
Environment   0 to 50°C (32 to 122°F); RH max 95%
Dimensions   280 x 203 x 84 mm (11.0 x 8.0 x 3.3")
Weight   1.9 kg (4.2 lbs.)

?ACCESSORIES:

Electrodes
HI 1043P Combination pH Electrode. Refillable w/ Double Junction
BNC Connection + pin
HI 1053P Combination pH Electrode. Refillable w/ Conical Tip
BNC + pin Connection
HI 1083P Combination pH Electrode w/ Micro Bulb
BNC + pin Connection
HI 1131P Refillable. Combination pH Electrode for the Laboratory and Beer Testing
BNC + pin Connection
HI 7662-T Stainless Steel Temperature Probe
Solutions
HI 5004L pH 4.01 buffer solution
HI 5007L pH 7.01 buffer solution
HI 5010L pH 10.01 buffer solution
HI 7061L General Purpose Cleaning Solution
1 x 500 mL bottle
HI 70300L Electrode Storage Solution
1 x 500 mL bottle
HI 7071 Electrolyte Solution. 3.5M KCl + AgCl
4 x 30 mL bottles
HI 7072 Electrolyte Solution. 1M KNO³
4 x 30 mL bottles
HI 7082 Electrolyte Solution. 3.5M KCl
4 x 30 mL bottle
Accessories
HI 710032 Paper for Built-in Printers
HI 710033 Ink Cartridge for Built-in Printers
HI 76405 Electrode Holder with Steel Base
HI 92000 Windows® Compatible Software
HI 920010 Cable for PC Connection. 9 to 9-pin


This product is available upon request. Contact us for more information.