{"id":1582120005,"title":"HANNA HI 2211-02 Basic pH \/ ORP \/ °C Meter \/ 2-Point Calibration","handle":"hi2211-02","description":"\u003cp style=\"text-align: justify;\"\u003eHI 2211 is a benchtop pH\/ORP and °C meter. HI 2211 adds measurement for ion concentration (ISE) and Oxidation Reduction Potential (ORP) in the mV range.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThis instrument also features a reading stability indicator used during calibration and a measurement memory\/memory recall function .\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003epH measurements for both instruments are compensated for the temperature effect manually or automatically with the HI 7662 temperature probe. This meter is equipped with an easy-to-read LCD which shows both the primary reading and ºC.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 2211-02 (230V) are supplied with HI 1131B pH electrode. HI 7662 temperature probe. HI 76404N electrode holder. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 7071S electrolyte solution (30 mL). HI 700661 cleaning solution sachet. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_2210_2211.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±399.9  mV; ±2000  mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 120.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV; 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±399.9  mV); ±1  mV (±2000  mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.4 °C (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 or 2 point with 5 memorized buffer values (pH 4.01. 6.86. 7.01. 9.18. 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic (with HI 7662 probe) or manual from -9.9 to 120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1131B. glass-body. single junction. refillable. BNC connector. 1 m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7662 with 1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.3 kg (2.9 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2026-06-25T16:22:59+12:00","created_at":"2015-09-01T15:10:15+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":69900,"price_min":69900,"price_max":69900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857209733,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI2211-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 2211-02 Basic pH \/ ORP \/ °C Meter \/ 2-Point Calibration","public_title":null,"options":["Default Title"],"price":69900,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/9040993-1_2015.jpeg?v=1465536541"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/9040993-1_2015.jpeg?v=1465536541","options":["Title"],"media":[{"alt":"HI 2211-02 Basic pH \/ ORP \/ °C Meter \/ 2-Point Calibration - Acorn Scientific","id":21285077091,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/9040993-1_2015.jpeg?v=1465536541"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/9040993-1_2015.jpeg?v=1465536541","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003eHI 2211 is a benchtop pH\/ORP and °C meter. HI 2211 adds measurement for ion concentration (ISE) and Oxidation Reduction Potential (ORP) in the mV range.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThis instrument also features a reading stability indicator used during calibration and a measurement memory\/memory recall function .\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003epH measurements for both instruments are compensated for the temperature effect manually or automatically with the HI 7662 temperature probe. This meter is equipped with an easy-to-read LCD which shows both the primary reading and ºC.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 2211-02 (230V) are supplied with HI 1131B pH electrode. HI 7662 temperature probe. HI 76404N electrode holder. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 7071S electrolyte solution (30 mL). HI 700661 cleaning solution sachet. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_2210_2211.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±399.9  mV; ±2000  mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 120.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV; 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±399.9  mV); ±1  mV (±2000  mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.4 °C (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 or 2 point with 5 memorized buffer values (pH 4.01. 6.86. 7.01. 9.18. 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic (with HI 7662 probe) or manual from -9.9 to 120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1131B. glass-body. single junction. refillable. BNC connector. 1 m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7662 with 1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.3 kg (2.9 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

HANNA HI 2211-02 Basic pH / ORP / °C Meter / 2-Point Calibration

Product Description

HI 2211 is a benchtop pH/ORP and °C meter. HI 2211 adds measurement for ion concentration (ISE) and Oxidation Reduction Potential (ORP) in the mV range.

This instrument also features a reading stability indicator used during calibration and a measurement memory/memory recall function .

pH measurements for both instruments are compensated for the temperature effect manually or automatically with the HI 7662 temperature probe. This meter is equipped with an easy-to-read LCD which shows both the primary reading and ºC.

 

Order Information:   HI 2211-02 (230V) are supplied with HI 1131B pH electrode. HI 7662 temperature probe. HI 76404N electrode holder. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 7071S electrolyte solution (30 mL). HI 700661 cleaning solution sachet. 12 VDC adapter and instructions.

Product Manuals

  Manual: Download

Specification :

Range pH -2.00 to 16.00 pH
  mV ±399.9  mV; ±2000  mV
  Temperature -20 to 120.0°C
Resolution pH 0.01 pH
  mV 0.1 mV; 1 mV
  Temperature 0.1 °C
Accuracy pH ±0.01 pH
  mV ±0.2 mV (±399.9  mV); ±1  mV (±2000  mV)
  Temperature ±0.4 °C (excluding probe error)
pH Calibration   automatic. 1 or 2 point with 5 memorized buffer values (pH 4.01. 6.86. 7.01. 9.18. 10.01)
Temperature Compensation   automatic (with HI 7662 probe) or manual from -9.9 to 120 °C
pH Electrode   HI 1131B. glass-body. single junction. refillable. BNC connector. 1 m cable (included)
Temperature Probe   HI 7662 with 1 m (3.3') cable (included)
Input Impedance   1012 Ohm
Power Supply   12 VDC adapter (included)
Environment   0 to 50°C (32 to 122°F); RH max 95%
Dimensions   235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)
Weight   1.3 kg (2.9 lbs.)