{"product_id":"hi2315-02","title":"HANNA HI 2315-02  Bench-Top Conductivity Meter","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003eThe HI 2315 Bench-Top \u003cspan id=\"cqq04270h2a_2\" class=\"cqq04270h2a\"\u003eConductivity Meter\u003c\/span\u003e is a multi-range meter with built-in automatic \u003cspan id=\"cqq04270h2a_1\" class=\"cqq04270h2a\"\u003etemperature compensation\u003c\/span\u003e for testing Conductivity. The HI 2315 replaces EC 215 and features a large. easy to read LCD. solution holders and an attractive redesigned case.  \u003cbr\u003e\u003cbr\u003eThe HI 2315 utilizes a four ring potentiometric probe with platinum sensor that offers greater versatility and accuracy over amperometric designs.  \u003cbr\u003e\u003cbr\u003eA potentiometric probe works on the principal of induction which eliminates the effects of polarization (a common problem of amperometric systems). Two outer rings apply an alternating voltage and induce a current loop in the solution while two inner rings measure the voltage drop induced by the current loop (which is dependent on the conductivity of the solution). By utilizing the 4-ring method. it is possible to measure very low to high conductivity levels (up to 200 mS\/cm) without changing probes.\u003cbr\u003e\u003cbr\u003eFEATURES\/BENEFITS:\u003cbr\u003e* Four ring potentiometric platinum probe\u003cbr\u003e* Four measurement ranges\u003cbr\u003e* ±1% F.s. accuracy\u003cbr\u003e* Manual calibration\u003cbr\u003e* Automatic Temperature Compensation\u003cbr\u003e* Large LCD\u003cbr\u003e* Built-in Solution Holders\u003cbr\u003e\u003cbr\u003eFEATURES IN DEPTH:\u003cbr\u003eFour ring probe - This allows for 1 probe to measure 4 ranges with no polarization effect.  It provides an increased accuracy (1% F.S.) over amperometric style meters.\u003cbr\u003e\u003cbr\u003eManual calibration -  This simple to use feature allows the HI2315 Bench-Top Conductivity Meter to be calibrated to any value within the measurement ranges (0.0 to 199.9 µs\/cm; 0 to 1999 µs\/cm; 0.00 to 19.99 ms\/cm; 0.0 to 199.9 ms\/cm)   It is also less expensive than models with auto-calibration\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eManual adjustable temperature correction coefficient (ß = Beta) - This simple to use feature allows for different temperature correction coefficients to be used based on the sample being tested.  It is adjustable from 0-2.5%\/°C.\u003cbr\u003e\u003cbr\u003eAutomatic Temperature Compensation - This helps provide the HI 2315 with higher accuracy since conductivity is very sensitive to temperature variations.\u003cbr\u003e\u003cbr\u003eLarge LCD - The new. larger LCD is bright and easy to read.\u003cbr\u003e\u003cbr\u003eBuilt-in Solution Holders - The HI 2315 has solution holders built into the casing.  This convenient feature saves space and prevents solutions from tipping over.\u003cbr\u003e\u003cbr\u003eRecessed Connector Bay - Protects connectors from liquids.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eSPECIFICATIONS:\u003cbr\u003eRange\u003cbr\u003e0.0 to 199.9 µs\/cm; 0 to 1999 µs\/cm; 0.00 to 19.99 ms\/cm; 0.0 to 199.9 mS\/cm\u003cbr\u003eResolution\u003cbr\u003e0.1 µs\/cm; 1 µs\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003cbr\u003eAccuracy (@20°C\/68°F)\u003cbr\u003e±1% F.s. (excluding probe error)\u003cbr\u003eCalibration\u003cbr\u003eManual. one point\u003cbr\u003eTemperature Compensation\u003cbr\u003eAutomatic. 0 to 50°C (32 to 122°F)with ß adjustable from 0 to 2.5%\/°C\u003cbr\u003eProbe\u003cbr\u003eHI 76303. platinum four ring conductivity probe with internal temperature sensor. Din connector and 1 m (3.3') cable (included)\u003cbr\u003ePower Supply\u003cbr\u003e12 VDC adapter (included)\u003cbr\u003eEnvironment\u003cbr\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003cbr\u003e\u003cbr\u003e\u003cbr\u003ePRIMARY APPLICATIONS:\u003cbr\u003e* Municipal drinking water. environmental studies\u003cbr\u003e* Printing industry - Fountain solution maintenance\u003cbr\u003e* \u003cspan id=\"cqq04270h2a_3\" class=\"cqq04270h2a\"\u003eWater Treatment\u003c\/span\u003e - Boiler\/Cooling Tower water quality\u003cbr\u003e* Agriculture - Fertilizer concentration\u003cbr\u003e* Food processing - salt levels in food. (i.e. making pickles)\u003cbr\u003e* Education - Teach students about EC\u003c\/p\u003e\u003cp\u003eElectrodes\u003cbr\u003eHI 76303 Platinum 4-Ring Potentiometric Conductivity Probe with internal temperature sensor. DIN connector and 1 m (3.3') cable\u003cbr\u003e\u003cbr\u003eSolutions\u003cbr\u003eHI 5030-12 12880 µS\/cm EC Solution (120ml)\u003cbr\u003eHI 5031-12 1413 µS\/cm EC Solution (120ml)\u003cbr\u003eHI 5033-12 84 µS\/cm EC Solution (120ml)\u003cbr\u003eHI 5034-12 80000 µS\/cm EC Solution (120ml)\u003cbr\u003eHI 7035L 111800 µS\/cm EC Solution (500ml)\u003cbr\u003eHI 7039L 5000 µS\/cm EC Solution (500ml)\u003cbr\u003eHI 7061L Cleaning Solution (500ml)\u003cbr\u003e\u003cbr\u003eAccessories\u003cbr\u003eHI 76404 Electrode Holder\u003cbr\u003eHI 710005 Power Adapter. 115 Vac to 12 VDC. US Plug\u003cbr\u003eHI 710006 Power Adapter. 230 Vac to 12 VDC. European Plug\u003cbr\u003eHI 740036P 100 mL Plastic Beaker\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 2315-01 (115V) and HI 2315-02 (230V) are supplied with HI 76303 Platinum 4-Ring Potentiometric Conductivity Probe. 12 VDC adapter and instruction manual.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":5764497477,"sku":"HI2315-02","price":1491.5,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/conductimetre-de-laboratoire-avec-gamme-resistivite-218_1-1_2015.jpeg?v=1465536559","url":"https:\/\/acornsci.co.nz\/products\/hi2315-02","provider":"Acorn Scientific","version":"1.0","type":"link"}