Providing a wide range of laboratory products and equipment from well known international suppliers

{"id":1582108613,"title":"HI 3810 CTK Dissolved Oxygen","handle":"hi3810","description":"\u003cp\u003eThe HANNA dissolved oxygen portable test kit can determine the oxygen concentration in water quickly and easily. A modified Winkler method is used. Manganous ions react with oxygen in the presence of potassium hydroxide to form a manganese oxide precipitate. An azide is present to prevent any nitrite ions from interfering with the test. On addition of acid. manganese oxide hydroxide oxidizes the iodide to iodine. Since the amount of iodine generated is equivalent to the oxygen in the sample. the concentration of iodine is calculated by titration of thiosulfate ions that reduce the iodine back to iodide ions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e HI 3810 test kit comes with 30 mL manganous sulfate solution. 30 mL alkali-azide reagent. 60 mL sulfuric acid solution (2). 10 mL starch indicator. 120 mL titrant solution. glass bottle with stopper. 10 mL calibrated vessel and calibrated syringe with tip.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/3810.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0-10.0 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest Increment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eModified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Tests\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eapprox. 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e910 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2017-11-22T12:50:18+13:00","created_at":"2015-09-01T15:08:44+12:00","vendor":"HANNA Instruments Inc.","type":"Electrochemical","tags":["brand_Hanna","Category_Electrochemical","Clearance_Hanna","Hanna_Clearance","Type_Chemical Test Kits"],"price":9200,"price_min":9200,"price_max":9200,"available":true,"price_varies":false,"compare_at_price":20000,"compare_at_price_min":20000,"compare_at_price_max":20000,"compare_at_price_varies":false,"variants":[{"id":4857182853,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI3810","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HI 3810 CTK Dissolved Oxygen","public_title":null,"options":["Default Title"],"price":9200,"weight":0,"compare_at_price":20000,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/31gluhj8kul__sl500_aa300_51e057ce8f0e2_2015.jpeg?v=1465536679"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/31gluhj8kul__sl500_aa300_51e057ce8f0e2_2015.jpeg?v=1465536679","options":["Title"],"content":"\u003cp\u003eThe HANNA dissolved oxygen portable test kit can determine the oxygen concentration in water quickly and easily. A modified Winkler method is used. Manganous ions react with oxygen in the presence of potassium hydroxide to form a manganese oxide precipitate. An azide is present to prevent any nitrite ions from interfering with the test. On addition of acid. manganese oxide hydroxide oxidizes the iodide to iodine. Since the amount of iodine generated is equivalent to the oxygen in the sample. the concentration of iodine is calculated by titration of thiosulfate ions that reduce the iodine back to iodide ions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e HI 3810 test kit comes with 30 mL manganous sulfate solution. 30 mL alkali-azide reagent. 60 mL sulfuric acid solution (2). 10 mL starch indicator. 120 mL titrant solution. glass bottle with stopper. 10 mL calibrated vessel and calibrated syringe with tip.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/3810.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0-10.0 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest Increment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eModified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Tests\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eapprox. 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e910 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

HI 3810 CTK Dissolved Oxygen

Product Description

The HANNA dissolved oxygen portable test kit can determine the oxygen concentration in water quickly and easily. A modified Winkler method is used. Manganous ions react with oxygen in the presence of potassium hydroxide to form a manganese oxide precipitate. An azide is present to prevent any nitrite ions from interfering with the test. On addition of acid. manganese oxide hydroxide oxidizes the iodide to iodine. Since the amount of iodine generated is equivalent to the oxygen in the sample. the concentration of iodine is calculated by titration of thiosulfate ions that reduce the iodine back to iodide ions.

 

Order Information:
HI 3810 test kit comes with 30 mL manganous sulfate solution. 30 mL alkali-azide reagent. 60 mL sulfuric acid solution (2). 10 mL starch indicator. 120 mL titrant solution. glass bottle with stopper. 10 mL calibrated vessel and calibrated syringe with tip.

Product Manuals

  Manual: Download

Specification :

Method   Titration
Range   0.0-10.0 mg/L
Smallest Increment   0.1 mg/L
Chemical Method   Modified Winkler
Number of Tests   approx. 110
Weight   910 g

 

$92.00 $200.00