{"product_id":"hi4222-02","title":"HANNA HI 4222-02 RESEARCH GRADE ISE\/pH\/ORP\/°C - 2 Channel-Meter","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 4222\u003c\/strong\u003e is a research grade pH. ORP and temperature benchtop meter. This instrument incorporates dual channels with a separate temperature input and support the external reference electrodes required by some pH and ISE sensors.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe customizable user interface can display two channels at the same time. showing the measurements in various modes: basic measurement with or without GLP information. graph or log history.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThese instruments offer multi-language support and contextual help is available through a dedicated Help key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through all measurement and calibration procedures to ensure measurements and procedures are performed properly.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHANNA’s pH Calibration Check™ diagnostics system ensures accurate readings every time by alerting users of potential problems during the calibration process. The Calibration Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions. After the guided calibration process. an electrode condition indicator is displayed on the LCD informing the user of the overall pH electrode status.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eAutomatic. semiautomatic and manual pH calibration is available in up to five points. with eight standard (1.68. 3.00. 4.01. 6.86. 7.01. 9.18. 10.01 and 12.45) and up to 5 custom buffers. The Out of Calibration Range and Cal Due features alert the user in the event the measurement is far from the calibration point or when the meter is due for recalibration. Proper. scheduled calibrations are crucial for accurate and repeatable measurements.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThis instrument also features up to five point Manual Selection and Custom Standard ISE calibration. From the on-screen list. users can select their ISE electrode parameter along with it’s standard configuration profile or create their own.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eUp to a four point automatic or custom standard conductivity calibration can be performed in up to four points as well as probe cell constant\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eUp to 10 profiles can be saved and recalled. eliminating the need to reconfigure each time when a different electrode is used. User definable configurations can include: temperature compensation in accordance with each parameter. ISO-potential points for pH and ISE. measurement units of ISE concentrations and ISE electrode type. temperature units. Three selectable logging modes are available: Automatic. Manual and AutoHold logging. Up to 100 logging lots can be stored for automatic or manual modes along with up to 200 USP reports. and up to 100 ISE methods reports. Automatic logging features a selectable area and sampling period while GLP information includes complete data about user calibration of each parameter and identification information for the instrument. user. and company. Data can be transferred to a PC via the opto-isolated PC interface via the RS232 or USB ports and HI 92000 software (optional).\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 4222-02 (230V) are supplied with HI 1131B pH electrode. HI 7662-T temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700661 electrode cleaning solution sachet (2). HI 7071S electrolyte solution (30 mL). HI 76404N electrode holder. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_4221_4222.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-2.000 to 20.000 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.1 pH; ±0.01 pH; ±0.002 pH ±1 LSD\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2000 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2 mV ±1 LSD\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 x 10\u003csup\u003e-6\u003c\/sup\u003e to 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e concentration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120°C; -4.0 to 248.0°F; 253.15 to 393.15K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C; 0.1°F; 0.1K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C; ±0.4°F; ±0.2K (without probe)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. up to five point calibration. eight standard buffers available (1.68. 3.00. 4.01. 6.86. 7.01.9.18. 10.01. 12.45). and five custom buffers\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eISE\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e automatic. up to five point calibration. 5 fixed standard solutions available for each measurement unit.  and 5 user defined standards\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Calibration Check™\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyes\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRel. mV Offset Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2000 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channel(s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e2 pH\/ORP\/ISE\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGLP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003ecell constant. reference temperature\/coefficient. calibration points. cal time stamp\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Temp. Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic or manual from -20.0 to 120.0°C\/-4.0 to 248.0°\/253 to 393K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecord\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e100 lots with 10.000 record\/lot\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInterval\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esettable between 1 and max log time\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. log on demand. auto HOLD\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e240 x 320 dot-matrix color LCD with on-screen help. graphing. language selection and custom configuration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection \/ Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eUSB and RS232 \/ 12 VDC adapter (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment \/ Dimensions \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e 0-50ºC (32 to 122ºF) (273 to 323K) RH max 95% non-condensing \/  160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) \/ 1.2 Kg (1.8 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857209541,"sku":"HI4222-02","price":2137.85,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi4222-1-1_2015.jpeg?v=1465536859","url":"https:\/\/acornsci.co.nz\/products\/hi4222-02","provider":"Acorn Scientific","version":"1.0","type":"link"}