{"id":1582062917,"title":"HI 705 Checker HC ® - Silica. LR","handle":"hi705","description":"\u003cp style=\"text-align: justify;\"\u003eThe HI 705 Checker®HC is a simple. accurate. and cost effective way to measure low ranges of silica. Designed as a more accurate alternative to chemical test kits. the HI 705 provides quick. accurate results in four easy steps.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 705 uses an adaptation of the ASTM D859 method of heteropoly blue method. The reaction between silica and reagents causes a blue tint in the sample.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003ePRIMARY APPLICATIONS:\u003c\/strong\u003e* Water Quality * Education * Environmental * Water Treatment (Boilers\/Cooling Towers)\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e The HI 705 Checker®HC is supplied with 2 cuvettes and caps. reagent starter kit (1 bottle reagent A. 6 packets of reagent B. and 6 packets of reagent C). 1 x 1.5V AAA battery. and an instruction manual.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003ca href=\"http:\/\/hannainst.com\/manuals\/ist705_03_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-7_medium.png?11580704866198517246\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 ppm\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C\/77°F)\u003c\/td\u003e\n\u003ctd\u003e±0.03ppm ± 5% of reading\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003ePhotodiode @610 nm\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM D859 method of heteropoly blue method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAuto off after 10 min. of inactivity\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eEnvironment 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2016-09-01T16:12:08+12:00","created_at":"2015-09-01T15:02:02+12:00","vendor":"HANNA Instruments Inc.","type":"Electrochemical","tags":["brand_Hanna","Category_Electrochemical","category_photometers","Clearance_Hanna","Hanna_Clearance"],"price":6500,"price_min":6500,"price_max":6500,"available":true,"price_varies":false,"compare_at_price":12300,"compare_at_price_min":12300,"compare_at_price_max":12300,"compare_at_price_varies":false,"variants":[{"id":4857020677,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI705","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HI 705 Checker HC ® - Silica. LR","public_title":null,"options":["Default Title"],"price":6500,"weight":0,"compare_at_price":12300,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi-705-400_2015.jpeg?v=1465537162"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi-705-400_2015.jpeg?v=1465537162","options":["Title"],"content":"\u003cp style=\"text-align: justify;\"\u003eThe HI 705 Checker®HC is a simple. accurate. and cost effective way to measure low ranges of silica. Designed as a more accurate alternative to chemical test kits. the HI 705 provides quick. accurate results in four easy steps.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 705 uses an adaptation of the ASTM D859 method of heteropoly blue method. The reaction between silica and reagents causes a blue tint in the sample.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003ePRIMARY APPLICATIONS:\u003c\/strong\u003e* Water Quality * Education * Environmental * Water Treatment (Boilers\/Cooling Towers)\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e The HI 705 Checker®HC is supplied with 2 cuvettes and caps. reagent starter kit (1 bottle reagent A. 6 packets of reagent B. and 6 packets of reagent C). 1 x 1.5V AAA battery. and an instruction manual.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003ca href=\"http:\/\/hannainst.com\/manuals\/ist705_03_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-7_medium.png?11580704866198517246\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 ppm\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C\/77°F)\u003c\/td\u003e\n\u003ctd\u003e±0.03ppm ± 5% of reading\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003ePhotodiode @610 nm\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM D859 method of heteropoly blue method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAuto off after 10 min. of inactivity\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eEnvironment 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}
HI 705 Checker HC ® - Silica. LR
Related Products
HI98103 CHECKER pH -Tester (0.01 pH Resolution)
$36.00 $91.00
HI 7040L Zero Oxygen Solution
$20.00 $40.00
Jeio Tech Model VM 96B Vortex
$299.00 $695.00