{"product_id":"hi83215-02","title":"HANNA HI 83215-02 Photometer for NPK Analysis - Agro","description":"\u003cp style=\"text-align: justify;\"\u003eDeciding which fertilizer to use can be overwhelming. but with a bit of knowledge you can be sure your garden will get the right amount of nutrients it needs. The first question you’ll need to answer is. “What analysis do I need?” The analysis is actually three numbers you see usually at the middle or bottom of fertilizer packages (for example 10-20-10). These numbers represent percentages of the three major nutrients plants need: nitrogen. phosphorus and potassium (NPK for short).\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 83215 is a multiparameter bench meter that measures twelve methods in low. medium and high ranges essential for monitoring greenhouse and hydroponics operations.  It’s three channels allow for a wide range of tests.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe optical system of HI 83215 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results. HI 83215 has powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu. and the Help Menu provides assistance for every step in the measurement process.  This meter can be connected to a PC via a USB cable. where the data can be managed with optional HI 92000 Windows® compatible software.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 83215-02\u003c\/strong\u003e (230V) is supplied with sample cuvettes and caps (4 ea.). sample preparation kit. cloth for wiping cuvettes (1). scissors. AC\/DC power adapter and instruction manual\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 83215C-100\u003c\/strong\u003e kit includes 10 mL cuvettes with caps (4 ea.). 100 mL plastic beaker. 170 mL plastic beaker. 100 mL graduated cylinder. 60 mL syringe with screw rim. 5 mL syringe. funnel. filter discs (25). spoon. pipettes (2). carbon powder packets (50). and demineralizer bottle with filter cap for approximately 12 liters of deionized water.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eSpecification :\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eup to 5 tungsten lamps with different narrow band interference filters.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eexternal 12 VDC power adapter or built-in rechargeable battery\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); max 90% RH non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 x 200 x 110 mm (9.2 x 7.87 x 4.33\")\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.9 Kg (2 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMulti Parameter Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003cth\u003eReagent Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 300 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 30.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphorus MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93706-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e20 to 200 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 20.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotassium MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 100 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eTurbidimetric\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93750-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e\u003cspan\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man83215_08_06_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857284997,"sku":"HI83215-02","price":1312.5,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/photometre-12-parametres-pour-lanalyse-des-nutriments-npk-1023_1_2015.jpeg?v=1443495555","url":"https:\/\/acornsci.co.nz\/products\/hi83215-02","provider":"Acorn Scientific","version":"1.0","type":"link"}