{"id":1582094469,"title":"HANNA HI 8633 Multi Range EC Meter with Multi-Range 0.0 to 199.9 mS\/cm MTC","handle":"hi8633","description":"\u003cp\u003eHI 8633 is a conductivity meter that has been designed for use in areas of production and quality control.\u003c\/p\u003e\n\u003cp\u003eThis meter utilizes four ring potentiometric probes that offer greater versatility over typical amperometric designs. These rugged probes are made of PVC—ideal for indoor. as well as outdoor measurements.\u003c\/p\u003e\n\u003cp\u003eTemperature compensation for HI 8633 is performed by manual adjustment.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour ring potentiometric probe\u003c\/li\u003e\n\u003cli\u003eOn-screen operation guide\u003c\/li\u003e\n\u003cli\u003eMultiple scales cover a wide range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 8633 is supplied with HI 76301D conductivity probe. 12880 µS\/cm HI 70030 calibration solution sachets (5). calibration screwdriver. battery. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man8734y_14_07_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.0 to 199.9 µS\/cm;\u003cbr\u003e 0 to 1999 µS\/cm;\u003cbr\u003e 0.00 to 19.99 mS\/cm;\u003cbr\u003e 0.0 to 199.9 mS\/cm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 µS\/cm;\u003cbr\u003e 1 µS\/cm;\u003cbr\u003e 0.01 mS\/cm;\u003cbr\u003e 0.1 mS\/cm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±1% F.S. (excluding probe error)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emanual. one point\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emanual. 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eHI 76301D four ring conductivity probe with DIN connector and 1 m (3.3’) cable (included)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e9V \/ approximately 100 hours of continuous use\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e230 g (8.1 oz.) \u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T16:29:19+12:00","created_at":"2015-09-01T15:06:28+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters"],"price":62600,"price_min":62600,"price_max":62600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857142533,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI8633","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 8633 Multi Range EC Meter with Multi-Range 0.0 to 199.9 mS\/cm MTC","public_title":null,"options":["Default Title"],"price":62600,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi8633_400-1_2015.jpeg?v=1443494802"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi8633_400-1_2015.jpeg?v=1443494802","options":["Title"],"media":[{"alt":null,"id":21275279459,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi8633_400-1_2015.jpeg?v=1443494802"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi8633_400-1_2015.jpeg?v=1443494802","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eHI 8633 is a conductivity meter that has been designed for use in areas of production and quality control.\u003c\/p\u003e\n\u003cp\u003eThis meter utilizes four ring potentiometric probes that offer greater versatility over typical amperometric designs. These rugged probes are made of PVC—ideal for indoor. as well as outdoor measurements.\u003c\/p\u003e\n\u003cp\u003eTemperature compensation for HI 8633 is performed by manual adjustment.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour ring potentiometric probe\u003c\/li\u003e\n\u003cli\u003eOn-screen operation guide\u003c\/li\u003e\n\u003cli\u003eMultiple scales cover a wide range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 8633 is supplied with HI 76301D conductivity probe. 12880 µS\/cm HI 70030 calibration solution sachets (5). calibration screwdriver. battery. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man8734y_14_07_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.0 to 199.9 µS\/cm;\u003cbr\u003e 0 to 1999 µS\/cm;\u003cbr\u003e 0.00 to 19.99 mS\/cm;\u003cbr\u003e 0.0 to 199.9 mS\/cm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 µS\/cm;\u003cbr\u003e 1 µS\/cm;\u003cbr\u003e 0.01 mS\/cm;\u003cbr\u003e 0.1 mS\/cm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±1% F.S. (excluding probe error)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emanual. one point\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emanual. 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eHI 76301D four ring conductivity probe with DIN connector and 1 m (3.3’) cable (included)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e9V \/ approximately 100 hours of continuous use\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e230 g (8.1 oz.) \u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}

HANNA HI 8633 Multi Range EC Meter with Multi-Range 0.0 to 199.9 mS/cm MTC

Product Description

HI 8633 is a conductivity meter that has been designed for use in areas of production and quality control.

This meter utilizes four ring potentiometric probes that offer greater versatility over typical amperometric designs. These rugged probes are made of PVC—ideal for indoor. as well as outdoor measurements.

Temperature compensation for HI 8633 is performed by manual adjustment.

 

  • Four ring potentiometric probe
  • On-screen operation guide
  • Multiple scales cover a wide range

 

Order Information:   HI 8633 is supplied with HI 76301D conductivity probe. 12880 µS/cm HI 70030 calibration solution sachets (5). calibration screwdriver. battery. instructions and rugged carrying case.

Product Manuals

  Manual: Download

Specification :

Range   0.0 to 199.9 µS/cm;
0 to 1999 µS/cm;
0.00 to 19.99 mS/cm;
0.0 to 199.9 mS/cm
Resolution   0.1 µS/cm;
1 µS/cm;
0.01 mS/cm;
0.1 mS/cm
Accuracy @ 20°C   ±1% F.S. (excluding probe error)
Calibration   manual. one point
Temperature
Compensation
  manual. 0 to 50°C (32 to 122°F) with ß=2%/°C
Probe   HI 76301D four ring conductivity probe with DIN connector and 1 m (3.3’) cable (included)
Battery Type / Life   9V / approximately 100 hours of continuous use
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)
Weight   230 g (8.1 oz.)

 