{"product_id":"hi902c2-02","title":"HANNA HI 902C2-02 - Titration System - Potentiometric - 2 analog boards","description":"\u003cp\u003e\u003cstrong\u003eIntuitive user interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUSB port allows for the transfer of methods and reports to a PC or another titrator via USB flash drive\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField upgradeable software\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRS232 port allows direct connection to an analytical laboratory balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti language support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFour working modes; potentiometric titrator. pH meter. mV meter. and ISE meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePotentiometric titrator\u003c\/li\u003e\n\u003cli\u003eLinked titration methods allow two methods to run in sequence\u003c\/li\u003e\n\u003cli\u003eAcid\/base. non-aqueous. ORP. complexation. back. precipitation titrations and titre determination can be performed\u003c\/li\u003e\n\u003cli\u003eSupports up to 100 titration methods (standard and user defined)\u003c\/li\u003e\n\u003cli\u003eSupplied standard methods pack or create your own\u003c\/li\u003e\n\u003cli\u003eTitration graph can be displayed on-screen and saved as a bitmap\u003c\/li\u003e\n\u003cli\u003eChoice of endpoint detection: equivalence point (1st or 2nd derivative) or fixed pH\/mV value\u003c\/li\u003e\n\u003cli\u003eReminders for titrant age and standardization expiration\u003c\/li\u003e\n\u003cli\u003eMultiple end-point titrations with multiple molecular weights and reaction ratios\u003c\/li\u003e\n\u003cli\u003eTwo sensor inputs with the addition of a second analog board\u003c\/li\u003e\n\u003cli\u003eSupports two burette dosing pumps with the ability to perform back titrations\u003c\/li\u003e\n\u003cli\u003eClip-Lock exchangeable burette system enables users to exchange burettes in a matter of seconds\u003c\/li\u003e\n\u003cli\u003e25 mL precision ground glass syringe with PTFE plunger\u003c\/li\u003e\n\u003cli\u003e40.000 step screw drive. piston dosing pump\u003c\/li\u003e\n\u003cli\u003e3-way motor driven valve\u003c\/li\u003e\n\u003cli\u003ePTFE burette tubing with polyurethane tube jacketing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003epH meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull featured research grade pH meter\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation (ATC)\u003c\/li\u003e\n\u003cli\u003eUp to five calibration points with automatic recognition of standard buffers\u003c\/li\u003e\n\u003cli\u003eUp to five custom buffers can be used for calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e mV (ORP) meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRelative mV calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e ISE meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNumerous concentration units including: mol\/L. mmol\/L. mg\/L. mg\/mL. ug\/L. %. ppt. ppm. g\/L. and user defined\u003c\/li\u003e\n\u003cli\u003eUp to 5 calibration points with 5 custom standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowerful Customization. Accurate Analysis\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C  can perform acid\/base. potentiometric. ORP. complexometric. precipitation. back titrations and titre  determinations.\u003c\/p\u003e\n\u003cp\u003eThe HI 902C dispenses the titrant. detects the endpoint and performs all necessary calculations automatically.\u003c\/p\u003e\n\u003cp\u003eThis versatile titrator supports up to 100 methods. standard or user defined. When powered on. the instrument initiates an internal diagnostics check and then readies itself for the first titration of the day. A large color LCD screen clearly shows the chosen method and related information. A real-time titration curve can be shown on the display; this feature is useful when new methods are tested or when a procedure needs to be optimized. At the end of the titration. all data. including the graph. are automatically stored in memory and can be copied via the built-in USB drive or through direct connection with a PC.\u003c\/p\u003e\n\u003cp\u003eThis titrator is supplied with a pack of standard methods or you can create your own. Methods (standard and user) can be upgraded. stored or deleted by connecting the titrator to a PC with HANNA software or USB flash drive. Software updates can also be performed using a USB flash drive.\u003c\/p\u003e\n\u003cp\u003eUsers can connect pH. ORP or ISE electrodes to the HI 902C. as well as create a complete workstation with a PC. monitor. keyboard and printer.\u003c\/p\u003e\n\u003cp\u003eThe HI 902C complies with GLP specifications. All GLP information from each sample can be stored. including ID number. date and time of analysis. electrode ID code. and last calibration date.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClip-Lock™ Exchangeable Burette System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith Clip-Lock™. it only takes a few seconds to exchange the reagent burettes to perform a different titration.\u003c\/p\u003e\n\u003cp\u003eThe Clip-Lock™ exchangeable burette system prevents cross contamination while reducing loss of time and reagents. Burettes simply slide out for quick exchanges and detaching the aspiration and dispensing tubes from the titrant bottles is easy.\u003c\/p\u003e\n\u003cp\u003eInterrupting an important cycle of analysis due to a malfunctioning burette is a thing of the past. With the HANNA Clip-Lock™ system you can simply substitute the burette and complete all your tests with the same titrant!\u003c\/p\u003e\n\u003cp\u003eHaving several prepared burettes on hand will make the HANNA HI 902C one of the fastest and most versatile titration systems on the market.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e HI 902C1-01 (115V) titrator with one analog board HI 902C1-02 (230V) titrator with one analog board HI 902C2-01 (115V) titrator with two analog boards HI 902C2-02 (230V) titrator with two analog boards All models include stirrer with stand. 25 mL glass burette. dosing pump drive. temperature sensor. USB cable. 256 Mb USB flash drive and PC software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Manual:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/manHI_901_902.pdf\"\u003eHI 902 (Titrators)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emV\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-2000.0 to 2000.0 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-2.000 to 20.000 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eISE\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1 x 10\u003csup\u003e-6\u003c\/sup\u003e to 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-5.0 to 105.0°C\/23 to 221°F\/268.2 to 378.2 K\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emV\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1\/0.01\/0.001 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eISE\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1. 0.1. 0.01\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1°C\/0.1°F\/0.1K\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003cbr\u003e(@25ºC\/77ºF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emV\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.1 mV \u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.001 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eISE\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.5% monovalent; ±1% divalent\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.1°C\/±0.2°F\/±0.1K (excluding probe error)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurette Sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5. 10. and 25 mL\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurette Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1\/40000\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.001 mL\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDosing Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.1% of full burette volume\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5.7” (320 x 240 pixel) backlit color LCD\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eEnglish. Portuguese. Spanish\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMethods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eload up to 100 methods (standard and user-defined)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurette Auto-Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eburette size is automatically recognized when inserted into the unit\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable Stirrer \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epropeller type. 100-2500 RPM. automatically held within 10% of the set value. resolution 100 rpm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003euser-selectable from 0.1 mL\/min to 2 x burette volumes\/min\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emanual or automatic (ATC)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd-point Determination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eequivalence point (1st or 2nd derivative) or fixed pH\/mV value\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to five point calibration. eight standard buffers and five custom buffers \u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Calibration \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003esingle point offset\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Calibration \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to five point calibration. seven standard solutions and five user defined standards\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotentiometric Titrations \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eacid-base (pH or mV-mode). redox. precipitation. complexometric. non-aqueous. ion-selective. argentometric. back titrations and titre determination\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003euser specified expression of concentration units to suit specific calculation requirements\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal Time \u0026amp; Stored Graphs \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emV-volume or pH-volume titration curve. 1st derivative curve or 2nd derivative curve. in pH-mode. mV-mode or ISE mode; pH\/mV\/concentration values versus time-datalogging results\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to 100 titration and pH\/mV\/ISE reports\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Host (Side)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eflash drive compatibility for transfers of methods and reports\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeripherals (Rear)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003econnections for VGA display. PC-keyboard. parallel printer. USB device input. RS232. interface for future expansion\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGLP Conformity \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003einstrumentation data storage and printing capabilities\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e10 to 40°C (50 to 104°F). up to 95% RH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Environment \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-20 to 70°C (-4 to 158°F). up to 95% RH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e“-01” models: 115VAC; “-02” models: 230VAC; 50\/60 Hz\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eapproximately 10 kg (22 lbs.) with one pump and stirrer assembly\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Literature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e\u003cspan\u003e  Literature: \u003c\/span\u003e\u003ca title=\"Download Literature\" href=\"http:\/\/www.hannainst.com\/literature\/HI902C_Leaflet.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857283717,"sku":"HI902C2-02","price":9878.21,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/systeme-de-titrage-automatique-1-carte-de-capteurs-2436_1-1_2015_02e321f8-3c67-43c1-828b-e899f942fa04.jpeg?v=1443495540","url":"https:\/\/acornsci.co.nz\/products\/hi902c2-02","provider":"Acorn Scientific","version":"1.0","type":"link"}