{"id":1582089861,"title":"HANNA HI 9124 Waterproof Portable pH Meter","handle":"hi9124","description":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eUser-selectable “calibration time out”\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eTutorial messages on LCD\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli\u003eBattery % displayed on startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HI 9124 is a waterproof pH meter. A large dual-level LCD displays both the pH and temperature along with an operational guide. Graphic symbols are displayed to help the users during the calibration process.\u003c\/p\u003e\n\u003cp\u003eThe pH \u003cspan id=\"k46hh_2\" class=\"k46hh\"\u003ecalibration procedure\u003c\/span\u003e is automatic with five memorized pH buffer values \u003cbr\u003eand buffer recognition to simplify the calibration process.\u003c\/p\u003e\n\u003cp\u003eThis meter utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for accurate. consistent results.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 9124 is supplied with HI 1230B pH electrode. HI 7662 \u003cspan id=\"k46hh_1\" class=\"k46hh\"\u003etemperature probe\u003c\/span\u003e. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. 100 mL plastic beaker. batteries. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e20.0 to 120.0°C \/ -4.0°F to 248.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.4°C \/ ±0.8°F (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic 1 or 2 point with 5 memorized buffer values (4.01. 6.86. 7.01. 9.18. 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrom 80 to 108%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic or manual. -20 to 120°C (-4 to 248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1230B. double junction. gel filled. BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7662 with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V AAA (3) \/ approximately 200 hours of continuous use. \u003cspan id=\"k46hh_3\" class=\"k46hh\"\u003eAuto\u003c\/span\u003e-off after 20 minutes of non-use (can be disabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%201230B\"\u003eHI 1230B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination pH Electrode. for Field Applications\u003cbr\u003e\u003csmall\u003eBNC Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%203131B\"\u003eHI 3131B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefillable Combination ORP Electrode for Titration and Laboratory Use\u003cbr\u003e\u003csmall\u003eBNC Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%205004L\"\u003eHI 5004L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 4.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%205007L\"\u003eHI 5007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 7.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%205010L\"\u003eHI 5010L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 10.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%207061L\"\u003eHI 7061L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Cleaning Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%207662\"\u003eHI 7662\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:29:33+12:00","created_at":"2015-09-01T15:05:44+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":76300,"price_min":76300,"price_max":76300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857131909,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI9124","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 9124 Waterproof Portable pH Meter","public_title":null,"options":["Default Title"],"price":76300,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/41-cub07p5l-1_2015.jpeg?v=1443494754"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/41-cub07p5l-1_2015.jpeg?v=1443494754","options":["Title"],"media":[{"alt":"HI 9124 Waterproof Portable pH Meter - Acorn Scientific","id":21273575523,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/41-cub07p5l-1_2015.jpeg?v=1443494754"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/41-cub07p5l-1_2015.jpeg?v=1443494754","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eUser-selectable “calibration time out”\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eTutorial messages on LCD\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli\u003eBattery % displayed on startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HI 9124 is a waterproof pH meter. A large dual-level LCD displays both the pH and temperature along with an operational guide. Graphic symbols are displayed to help the users during the calibration process.\u003c\/p\u003e\n\u003cp\u003eThe pH \u003cspan id=\"k46hh_2\" class=\"k46hh\"\u003ecalibration procedure\u003c\/span\u003e is automatic with five memorized pH buffer values \u003cbr\u003eand buffer recognition to simplify the calibration process.\u003c\/p\u003e\n\u003cp\u003eThis meter utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for accurate. consistent results.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 9124 is supplied with HI 1230B pH electrode. HI 7662 \u003cspan id=\"k46hh_1\" class=\"k46hh\"\u003etemperature probe\u003c\/span\u003e. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. 100 mL plastic beaker. batteries. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e20.0 to 120.0°C \/ -4.0°F to 248.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.4°C \/ ±0.8°F (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic 1 or 2 point with 5 memorized buffer values (4.01. 6.86. 7.01. 9.18. 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrom 80 to 108%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic or manual. -20 to 120°C (-4 to 248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1230B. double junction. gel filled. BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7662 with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V AAA (3) \/ approximately 200 hours of continuous use. \u003cspan id=\"k46hh_3\" class=\"k46hh\"\u003eAuto\u003c\/span\u003e-off after 20 minutes of non-use (can be disabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%201230B\"\u003eHI 1230B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination pH Electrode. for Field Applications\u003cbr\u003e\u003csmall\u003eBNC Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%203131B\"\u003eHI 3131B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefillable Combination ORP Electrode for Titration and Laboratory Use\u003cbr\u003e\u003csmall\u003eBNC Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%205004L\"\u003eHI 5004L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 4.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%205007L\"\u003eHI 5007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 7.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%205010L\"\u003eHI 5010L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH 10.01 buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%207061L\"\u003eHI 7061L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Cleaning Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044003\u0026amp;ProdCode=HI%207662\"\u003eHI 7662\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 9124 Waterproof Portable pH Meter

Product Description
  • User-selectable “calibration time out”
  • Automatic calibration
  • Automatic Temperature Compensation
  • Tutorial messages on LCD
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings
  • Battery % displayed on startup.

 

The HI 9124 is a waterproof pH meter. A large dual-level LCD displays both the pH and temperature along with an operational guide. Graphic symbols are displayed to help the users during the calibration process.

The pH calibration procedure is automatic with five memorized pH buffer values 
and buffer recognition to simplify the calibration process.

This meter utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for accurate. consistent results.

 

Order Information:
HI 9124 is supplied with HI 1230B pH electrode. HI 7662 temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. 100 mL plastic beaker. batteries. instructions and hard carrying case.

SPECIFICATIONS:

Range pH -2.00 to 16.00 pH
  Temperature 20.0 to 120.0°C / -4.0°F to 248.0°F
Resolution pH 0.01 pH
  Temperature 0.1°C / 0.1°F
Accuracy @ 20°C pH ±0.01 pH
  Temperature ±0.4°C / ±0.8°F (excluding probe error)
pH Calibration   automatic 1 or 2 point with 5 memorized buffer values (4.01. 6.86. 7.01. 9.18. 10.01)
Offset Calibration   ±1 pH
Slope Calibration   From 80 to 108%
Temperature Compensation   automatic or manual. -20 to 120°C (-4 to 248°F)
pH Electrode   HI 1230B. double junction. gel filled. BNC connector and 1 m (3.3’) cable (included)
Temperature Probe   HI 7662 with 1 m (3.3’) cable (included)
Input Impedance   1012 Ohm
Battery Type / Life   1.5V AAA (3) / approximately 200 hours of continuous use. Auto-off after 20 minutes of non-use (can be disabled)
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)
Weight   300 g (10.6 oz.)
Electrodes
HI 1230B Combination pH Electrode. for Field Applications
BNC Connection
HI 3131B Refillable Combination ORP Electrode for Titration and Laboratory Use
BNC Connection
Solutions
HI 5004L pH 4.01 buffer solution
HI 5007L pH 7.01 buffer solution
HI 5010L pH 10.01 buffer solution
HI 70300L Electrode Storage Solution
1 x 500 mL bottle
HI 7061L General Purpose Cleaning Solution
1 x 500 mL bottle
Probes
HI 7662 Stainless Steel Temperature Probe

This product is available upon request. Contact us for more information.