Email info@acornsci.com for orders and inquiries.

{"id":1582101893,"title":"HANNA HI93522 2-Channel Thermistor Thermometer with Cal Feature","handle":"hi93522","description":"\u003cul\u003e\n\u003cli\u003eTwo input channels\u003c\/li\u003e\n\u003cli\u003eWaterproof casing\u003c\/li\u003e\n\u003cli\u003eHigh accuracy ± 0.4°C\/± 0.8°F\u003c\/li\u003e\n\u003cli\u003eHOLD button\u003c\/li\u003e\n\u003cli\u003eBEPS and low battery warning\u003c\/li\u003e\n\u003cli\u003e2000 hour battery life\u003c\/li\u003e\n\u003cli\u003eBacklit display\u003c\/li\u003e\n\u003cli\u003eCalibration feature\u003c\/li\u003e\n\u003cli\u003eReading store and recall\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 93522\u003c\/strong\u003e is a waterproof two-channel thermometer. ideal for monitoring two samples at once. This easy to use thermometer displays the temperature together with high and low readings.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 93522 allows the user to view the differences between each channel (along with the high and low values or current temperature at each probe). as well as the variance from a reference temperature.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFor even greater accuracy. this meter incorporates a CAL button that allows the operator to remove the combined meter and probe interchange error in an ice bath at 0°C.  HI 93522 can also store and recall a reading as well as allowing the user to set the auto-off time period and activate the backlight for low light conditions.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HOLD button freezes the display to allow the user time to record readings. A diverse assortment of HI 762 probes and cable lengths are available. Probes can be ordered with different handle colors to prevent cross-contamination.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eAdvanced battery management features include a display of remaining battery power at startup. low battery warning and BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 93522 is supplied with HI 762BL temperature probe. batteries and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-50.0 to 150.0°C; -58.0 to 302.0°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C; 0.1°F (-58.0 to 230.0°F) and 0.2°F (outside)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.4°C; ±0.8°F (for 1 year. excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 762BL air\/liquid. stainless steel thermistor temperature probe  with black handle and 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AA (3) \/ approximately 2000 hours of continuous use (with backlight off); auto-off selectable after 8 or 60 minutes of non-use (can be disabled)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-10 to 50°C (14 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e150 x 80 x 36 mm (5.9 x 3.1 x 1.4\")\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 g (8.3 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2024-06-21T14:34:40+12:00","created_at":"2015-09-01T15:07:43+12:00","vendor":"Hanna Instruments","type":"Temp \u0026 Humidity","tags":["category_Temp \u0026 Humidity","Manufacturer_Hanna Instruments","Type_Devices"],"price":38400,"price_min":38400,"price_max":38400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857166341,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI93522","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI93522 2-Channel Thermistor Thermometer with Cal Feature","public_title":null,"options":["Default Title"],"price":38400,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi93522_400-1_2015.jpeg?v=1469853984"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi93522_400-1_2015.jpeg?v=1469853984","options":["Title"],"media":[{"alt":"2-Channel Thermistor Thermometer with Cal Feature - Acorn Scientific","id":21277835363,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi93522_400-1_2015.jpeg?v=1469853984"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi93522_400-1_2015.jpeg?v=1469853984","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli\u003eTwo input channels\u003c\/li\u003e\n\u003cli\u003eWaterproof casing\u003c\/li\u003e\n\u003cli\u003eHigh accuracy ± 0.4°C\/± 0.8°F\u003c\/li\u003e\n\u003cli\u003eHOLD button\u003c\/li\u003e\n\u003cli\u003eBEPS and low battery warning\u003c\/li\u003e\n\u003cli\u003e2000 hour battery life\u003c\/li\u003e\n\u003cli\u003eBacklit display\u003c\/li\u003e\n\u003cli\u003eCalibration feature\u003c\/li\u003e\n\u003cli\u003eReading store and recall\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 93522\u003c\/strong\u003e is a waterproof two-channel thermometer. ideal for monitoring two samples at once. This easy to use thermometer displays the temperature together with high and low readings.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 93522 allows the user to view the differences between each channel (along with the high and low values or current temperature at each probe). as well as the variance from a reference temperature.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFor even greater accuracy. this meter incorporates a CAL button that allows the operator to remove the combined meter and probe interchange error in an ice bath at 0°C.  HI 93522 can also store and recall a reading as well as allowing the user to set the auto-off time period and activate the backlight for low light conditions.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HOLD button freezes the display to allow the user time to record readings. A diverse assortment of HI 762 probes and cable lengths are available. Probes can be ordered with different handle colors to prevent cross-contamination.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eAdvanced battery management features include a display of remaining battery power at startup. low battery warning and BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 93522 is supplied with HI 762BL temperature probe. batteries and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-50.0 to 150.0°C; -58.0 to 302.0°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C; 0.1°F (-58.0 to 230.0°F) and 0.2°F (outside)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.4°C; ±0.8°F (for 1 year. excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 762BL air\/liquid. stainless steel thermistor temperature probe  with black handle and 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AA (3) \/ approximately 2000 hours of continuous use (with backlight off); auto-off selectable after 8 or 60 minutes of non-use (can be disabled)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-10 to 50°C (14 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e150 x 80 x 36 mm (5.9 x 3.1 x 1.4\")\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 g (8.3 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}

HANNA HI93522 2-Channel Thermistor Thermometer with Cal Feature

Product Description
  • Two input channels
  • Waterproof casing
  • High accuracy ± 0.4°C/± 0.8°F
  • HOLD button
  • BEPS and low battery warning
  • 2000 hour battery life
  • Backlit display
  • Calibration feature
  • Reading store and recall

HI 93522 is a waterproof two-channel thermometer. ideal for monitoring two samples at once. This easy to use thermometer displays the temperature together with high and low readings.

HI 93522 allows the user to view the differences between each channel (along with the high and low values or current temperature at each probe). as well as the variance from a reference temperature.

For even greater accuracy. this meter incorporates a CAL button that allows the operator to remove the combined meter and probe interchange error in an ice bath at 0°C.  HI 93522 can also store and recall a reading as well as allowing the user to set the auto-off time period and activate the backlight for low light conditions.

The HOLD button freezes the display to allow the user time to record readings. A diverse assortment of HI 762 probes and cable lengths are available. Probes can be ordered with different handle colors to prevent cross-contamination.

Advanced battery management features include a display of remaining battery power at startup. low battery warning and BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.

 

Order Information:   HI 93522 is supplied with HI 762BL temperature probe. batteries and instructions.

Specification :

Range   -50.0 to 150.0°C; -58.0 to 302.0°F
Resolution   0.1°C; 0.1°F (-58.0 to 230.0°F) and 0.2°F (outside)
Accuracy   ±0.4°C; ±0.8°F (for 1 year. excluding probe error)
Probe   HI 762BL air/liquid. stainless steel thermistor temperature probe  with black handle and 1 m (3.3’) cable (included)
Battery Type / Life   1.5V AA (3) / approximately 2000 hours of continuous use (with backlight off); auto-off selectable after 8 or 60 minutes of non-use (can be disabled)
Environment   -10 to 50°C (14 to 122°F); RH max 100%
Dimensions   150 x 80 x 36 mm (5.9 x 3.1 x 1.4")
Weight   235 g (8.3 oz.)

 