Email info@acornsci.com for orders and inquiries.

{"id":1582083269,"title":"HANNA HI 93552R Dual-channel. K. J. T-Type Thermocouple Thermometer with PC Connectivity","handle":"hi93552r","description":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts K. J. T – thermocouples\u003c\/li\u003e\n\u003cli\u003eWaterproof casing\u003c\/li\u003e\n\u003cli\u003eHigh\/Low function\u003c\/li\u003e\n\u003cli\u003e°C to °F shifting\u003c\/li\u003e\n\u003cli\u003eHOLD function\u003c\/li\u003e\n\u003cli\u003eBEPS and low battery warning\u003c\/li\u003e\n\u003cli\u003eBattery life indicator at start-up\u003c\/li\u003e\n\u003cli\u003eAuto-off capability\u003c\/li\u003e\n\u003cli\u003eOne point calibration\u003c\/li\u003e\n\u003cli\u003eBacklight display\u003c\/li\u003e\n\u003cli\u003ePC and printer compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 93552R is a dual-channel waterproof K. J. and T-type thermocouple thermometer that can switch between  thermocouple types  at a touch of a button.\u003c\/p\u003e\n\u003cp\u003eAt any time. users can switch views to see all information on either channel. display current temperature or average along with the high and low values. Users can also see the difference between the two channels simultaneously along with the high and low of the difference.\u003c\/p\u003e\n\u003cp\u003eThe HOLD button freezes the display to allow the user time to record readings. The  °C\/°F button switches between the Celsius and Fahrenheit temperature scale. The CLEAR button restarts the evaluation of high and low values.\u003c\/p\u003e\n\u003cp\u003eFor high accuracy. HI 93552R features a CAL button to allow the operator a simple one point calibration in an ice bath at 0°C when probe interchange occurs.\u003c\/p\u003e\n\u003cp\u003eHI 93552R adds RS232 output that allows for data transfer to a PC or printer.\u003c\/p\u003e\n\u003cp\u003eThe instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 93552R is supplied with batteries. instructions and protective case.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eAccessories\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eK\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-200.0 to 999.9°C; 1000 to 1371°C;\u003cbr\u003e-328.0 to 999.9°F; 1000 to 2500°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eJ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-200.0 to 999.9°C; -328.0 to 999.9°F; 1000 to 1832°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eT\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-200.0 to 400.0°C; -328.0 to 752.0°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eK\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C);\u003cbr\u003e0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F);\u003cbr\u003e0.3°F (-328.0 to 250.0°F); 1°F (1000 to 2500°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eJ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (-200.0 to 999.9°C);\u003cbr\u003e0.1°F (-149.9 to 999.9°F); 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eT\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C);\u003cbr\u003e0.1°F (0.0 to 752.0°F); 0.2°F (-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.5°C (-100.0 to 999.9°C); ±1°C (outside);\u003cbr\u003e±1°F (-148.0 to 999.9°F); ±1.5° (outside);\u003cbr\u003e(for 1 year. excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 766 series K-type thermocouple (not included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eRS232 serial port\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AA (3) \/ approximately 500 hours of continuous use (with backlight off); auto-off: after 60 minutes of non-use (HI 93542); selectable after 8 or 60 minutes of non-use (HI 93552) (can be disabled for all models)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-10 to 50°C (14 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 g (8.3 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20710007\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20710007\"\u003eHI 710007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShockproof Rubber Boot\u003cbr\u003e\u003csmall\u003eErgo Style Casing. Blue\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20710008\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20710008\"\u003eHI 710008\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShockproof Rubber Boot\u003cbr\u003e\u003csmall\u003eErgo Style Casing. Orange\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%2092000\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20920011\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20920011\"\u003eHI 920011\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 Cable for PC Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20766C\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20766C\"\u003eHI 766C\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePenetration Thermocouple Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20766E1\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20766E1\"\u003eHI 766E1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Thermocouple Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e\u003cspan\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93542_551_552.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93542_551_552.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:29:43+12:00","created_at":"2015-09-01T15:04:45+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Thermometers"],"price":53010,"price_min":53010,"price_max":53010,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857099973,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI93552R","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 93552R Dual-channel. K. J. T-Type Thermocouple Thermometer with PC Connectivity","public_title":null,"options":["Default Title"],"price":53010,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/kjt-typ-thermometer-mit-pc-interface-2-eingange-1112_1-1_2015.jpeg?v=1443494697"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/kjt-typ-thermometer-mit-pc-interface-2-eingange-1112_1-1_2015.jpeg?v=1443494697","options":["Title"],"media":[{"alt":"HI 93552R Dual-channel. K. J. T-Type Thermocouple Thermometer with PC Connectivity - Acorn Scientific","id":21271773283,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/kjt-typ-thermometer-mit-pc-interface-2-eingange-1112_1-1_2015.jpeg?v=1443494697"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/kjt-typ-thermometer-mit-pc-interface-2-eingange-1112_1-1_2015.jpeg?v=1443494697","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts K. J. T – thermocouples\u003c\/li\u003e\n\u003cli\u003eWaterproof casing\u003c\/li\u003e\n\u003cli\u003eHigh\/Low function\u003c\/li\u003e\n\u003cli\u003e°C to °F shifting\u003c\/li\u003e\n\u003cli\u003eHOLD function\u003c\/li\u003e\n\u003cli\u003eBEPS and low battery warning\u003c\/li\u003e\n\u003cli\u003eBattery life indicator at start-up\u003c\/li\u003e\n\u003cli\u003eAuto-off capability\u003c\/li\u003e\n\u003cli\u003eOne point calibration\u003c\/li\u003e\n\u003cli\u003eBacklight display\u003c\/li\u003e\n\u003cli\u003ePC and printer compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 93552R is a dual-channel waterproof K. J. and T-type thermocouple thermometer that can switch between  thermocouple types  at a touch of a button.\u003c\/p\u003e\n\u003cp\u003eAt any time. users can switch views to see all information on either channel. display current temperature or average along with the high and low values. Users can also see the difference between the two channels simultaneously along with the high and low of the difference.\u003c\/p\u003e\n\u003cp\u003eThe HOLD button freezes the display to allow the user time to record readings. The  °C\/°F button switches between the Celsius and Fahrenheit temperature scale. The CLEAR button restarts the evaluation of high and low values.\u003c\/p\u003e\n\u003cp\u003eFor high accuracy. HI 93552R features a CAL button to allow the operator a simple one point calibration in an ice bath at 0°C when probe interchange occurs.\u003c\/p\u003e\n\u003cp\u003eHI 93552R adds RS232 output that allows for data transfer to a PC or printer.\u003c\/p\u003e\n\u003cp\u003eThe instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 93552R is supplied with batteries. instructions and protective case.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eAccessories\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eK\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-200.0 to 999.9°C; 1000 to 1371°C;\u003cbr\u003e-328.0 to 999.9°F; 1000 to 2500°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eJ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-200.0 to 999.9°C; -328.0 to 999.9°F; 1000 to 1832°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eT\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-200.0 to 400.0°C; -328.0 to 752.0°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eK\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C);\u003cbr\u003e0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F);\u003cbr\u003e0.3°F (-328.0 to 250.0°F); 1°F (1000 to 2500°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eJ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (-200.0 to 999.9°C);\u003cbr\u003e0.1°F (-149.9 to 999.9°F); 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eT\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C);\u003cbr\u003e0.1°F (0.0 to 752.0°F); 0.2°F (-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.5°C (-100.0 to 999.9°C); ±1°C (outside);\u003cbr\u003e±1°F (-148.0 to 999.9°F); ±1.5° (outside);\u003cbr\u003e(for 1 year. excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 766 series K-type thermocouple (not included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eRS232 serial port\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AA (3) \/ approximately 500 hours of continuous use (with backlight off); auto-off: after 60 minutes of non-use (HI 93542); selectable after 8 or 60 minutes of non-use (HI 93552) (can be disabled for all models)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-10 to 50°C (14 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 g (8.3 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20710007\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20710007\"\u003eHI 710007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShockproof Rubber Boot\u003cbr\u003e\u003csmall\u003eErgo Style Casing. Blue\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20710008\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20710008\"\u003eHI 710008\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShockproof Rubber Boot\u003cbr\u003e\u003csmall\u003eErgo Style Casing. Orange\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%2092000\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20920011\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20920011\"\u003eHI 920011\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 Cable for PC Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20766C\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20766C\"\u003eHI 766C\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePenetration Thermocouple Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20766E1\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044023\u0026amp;ProdCode=HI%20766E1\"\u003eHI 766E1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Thermocouple Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e\u003cspan\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93542_551_552.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93542_551_552.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 93552R Dual-channel. K. J. T-Type Thermocouple Thermometer with PC Connectivity

Product Description


 

  • Accepts K. J. T – thermocouples
  • Waterproof casing
  • High/Low function
  • °C to °F shifting
  • HOLD function
  • BEPS and low battery warning
  • Battery life indicator at start-up
  • Auto-off capability
  • One point calibration
  • Backlight display
  • PC and printer compatible

 

HI 93552R is a dual-channel waterproof K. J. and T-type thermocouple thermometer that can switch between  thermocouple types  at a touch of a button.

At any time. users can switch views to see all information on either channel. display current temperature or average along with the high and low values. Users can also see the difference between the two channels simultaneously along with the high and low of the difference.

The HOLD button freezes the display to allow the user time to record readings. The  °C/°F button switches between the Celsius and Fahrenheit temperature scale. The CLEAR button restarts the evaluation of high and low values.

For high accuracy. HI 93552R features a CAL button to allow the operator a simple one point calibration in an ice bath at 0°C when probe interchange occurs.

HI 93552R adds RS232 output that allows for data transfer to a PC or printer.

The instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.

 

Order Information:
HI 93552R is supplied with batteries. instructions and protective case.

  • Specifications
  • Accessories
  • Downloads
Range K -200.0 to 999.9°C; 1000 to 1371°C;
-328.0 to 999.9°F; 1000 to 2500°F
  J -200.0 to 999.9°C; -328.0 to 999.9°F; 1000 to 1832°F
  T -200.0 to 400.0°C; -328.0 to 752.0°F
Resolution K 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C);
0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F);
0.3°F (-328.0 to 250.0°F); 1°F (1000 to 2500°F)
  J 0.1°C (-200.0 to 999.9°C);
0.1°F (-149.9 to 999.9°F); 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F)
  T 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C);
0.1°F (0.0 to 752.0°F); 0.2°F (-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F)
Accuracy   ±0.5°C (-100.0 to 999.9°C); ±1°C (outside);
±1°F (-148.0 to 999.9°F); ±1.5° (outside);
(for 1 year. excluding probe error)
Probe   HI 766 series K-type thermocouple (not included)
PC Connection   RS232 serial port
Battery Type / Life   1.5V AA (3) / approximately 500 hours of continuous use (with backlight off); auto-off: after 60 minutes of non-use (HI 93542); selectable after 8 or 60 minutes of non-use (HI 93552) (can be disabled for all models)
Environment   -10 to 50°C (14 to 122°F); RH max 100%
Dimensions   150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’)
Weight   235 g (8.3 oz.)
Accessories
HI 710007 Shockproof Rubber Boot
Ergo Style Casing. Blue
HI 710008 Shockproof Rubber Boot
Ergo Style Casing. Orange
HI 92000 Windows® Compatible Software
HI 920011 RS232 Cable for PC Connection
Probes
HI 766C Penetration Thermocouple Probe
HI 766E1 General Purpose Thermocouple Probe
Product Manuals

  Manual: Download

This product is available upon request. Contact us for more information.