Email info@acornsci.com for orders and inquiries.

{"id":1582141317,"title":"HANNA HI 96705 Silica 0.00 - 2.00 mg\/l - Photometer mobile","handle":"hi96705","description":"\u003cp\u003eSilica is found in all natural waters in the dissolved mineral form. Silica is only slightly soluble in water; solubility and therefore the form of silica in water depends on the pH level of the water and on the minerals containing silica in contact with water.\u003c\/p\u003e\n\u003cp\u003eSilica’s presence in industrial applications is undesirable since it causes scale. In particular. high pressure turbines are highly effected by this factor.\u003c\/p\u003e\n\u003cp\u003eHeating systems and reverse osmosis plants also require monitoring of silica.\u003c\/p\u003e\n\u003cp\u003eThe HI 96705 meter measures the silica (SiO\u003csub\u003e2\u003c\/sub\u003e) content in water and wastewater in the 0.00 to 2.00 mg\/L (ppm) range.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96705\u003c\/strong\u003e is supplied with sample cuvettes with caps (2 ea.). battery and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96705_24_11_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use in measuring mode; after 1 hour of non-use in calibration mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM D859 method of the heteropoly blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T16:19:33+12:00","created_at":"2015-09-01T15:13:05+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":40660,"price_min":40660,"price_max":40660,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857251397,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96705","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96705 Silica 0.00 - 2.00 mg\/l - Photometer mobile","public_title":null,"options":["Default Title"],"price":40660,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e4f2b863430_2015_c206b3fa-a4e2-4c95-b7b8-a886f4b9e58c.jpeg?v=1443495370"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e4f2b863430_2015_c206b3fa-a4e2-4c95-b7b8-a886f4b9e58c.jpeg?v=1443495370","options":["Title"],"media":[{"alt":null,"id":21292646499,"position":1,"preview_image":{"aspect_ratio":1.028,"height":800,"width":822,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e4f2b863430_2015_c206b3fa-a4e2-4c95-b7b8-a886f4b9e58c.jpeg?v=1443495370"},"aspect_ratio":1.028,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e4f2b863430_2015_c206b3fa-a4e2-4c95-b7b8-a886f4b9e58c.jpeg?v=1443495370","width":822}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eSilica is found in all natural waters in the dissolved mineral form. Silica is only slightly soluble in water; solubility and therefore the form of silica in water depends on the pH level of the water and on the minerals containing silica in contact with water.\u003c\/p\u003e\n\u003cp\u003eSilica’s presence in industrial applications is undesirable since it causes scale. In particular. high pressure turbines are highly effected by this factor.\u003c\/p\u003e\n\u003cp\u003eHeating systems and reverse osmosis plants also require monitoring of silica.\u003c\/p\u003e\n\u003cp\u003eThe HI 96705 meter measures the silica (SiO\u003csub\u003e2\u003c\/sub\u003e) content in water and wastewater in the 0.00 to 2.00 mg\/L (ppm) range.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96705\u003c\/strong\u003e is supplied with sample cuvettes with caps (2 ea.). battery and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96705_24_11_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use in measuring mode; after 1 hour of non-use in calibration mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM D859 method of the heteropoly blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

HANNA HI 96705 Silica 0.00 - 2.00 mg/l - Photometer mobile

Product Description

Silica is found in all natural waters in the dissolved mineral form. Silica is only slightly soluble in water; solubility and therefore the form of silica in water depends on the pH level of the water and on the minerals containing silica in contact with water.

Silica’s presence in industrial applications is undesirable since it causes scale. In particular. high pressure turbines are highly effected by this factor.

Heating systems and reverse osmosis plants also require monitoring of silica.

The HI 96705 meter measures the silica (SiO2) content in water and wastewater in the 0.00 to 2.00 mg/L (ppm) range.

 

Order Information: HI 96705 is supplied with sample cuvettes with caps (2 ea.). battery and instructions.

Product Manuals

  Manual: Download

Specification :

Range   0.00 to 2.00 mg/L (ppm)
Resolution   0.01 mg/L (ppm)
Accuracy   ±0.03 mg/L ±3% of reading @ 25°C
Light Source   Tungsten lamp
Light Detector   Silicon photocell with narrow band interference filter @ 610 nm
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply   (1) 9V battery
Auto-off   After 10 minutes of non-use in measuring mode; after 1 hour of non-use in calibration mode
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)
Method   Adaptation of the ASTM D859 method of the heteropoly blue method

 

This product is available upon request. Contact us for more information.