{"id":2012145349,"title":"HANNA HI96707C Nitrite LR 0.000-0.600 mg\/L - Photometer with Cal kits \u0026 Ccsing","handle":"hi96707c","description":"\u003cp\u003eNitrites are an intermediate product in the nitrogen cycle and are produced by ammonia oxidation with water. or even originate in industrial waste directly. They must not be present in drinking water.\u003c\/p\u003e\u003cp\u003eThe HI 96707 measures the Nitrogen-Nitrite content in the 0.000 to 0.600 mg\/L (ppm) range. in drinking. surface and saline water samples and in domestic and industrial wastes.\u003c\/p\u003e\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96707C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96707_04_07_11.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/ist96707_04_07_11.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.000 to 0.600 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±4% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of an EPA approved method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F);max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e","published_at":"2026-06-25T15:26:30+12:00","created_at":"2015-09-04T15:10:12+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":63000,"price_min":63000,"price_max":63000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764101189,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96707C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI96707C Nitrite LR 0.000-0.600 mg\/L - Photometer with Cal kits \u0026 Ccsing","public_title":null,"options":["Default Title"],"price":63000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015_bdf1c19a-88b1-4303-bcf4-33ca1adeb61b.jpeg?v=1443494567","\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nitrit-bis-0600-mgl-1300_1-1_2015.jpeg?v=1443494567"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015_bdf1c19a-88b1-4303-bcf4-33ca1adeb61b.jpeg?v=1443494567","options":["Title"],"media":[{"alt":"HANNA HI96707C Nitrite LR 0.000-0.600 mg\/L - Photometer with Cal kits \u0026 Ccsing - Acorn Scientific","id":25181585507,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015_bdf1c19a-88b1-4303-bcf4-33ca1adeb61b.jpeg?v=1443494567"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015_bdf1c19a-88b1-4303-bcf4-33ca1adeb61b.jpeg?v=1443494567","width":800},{"alt":"HANNA HI96707C Nitrite LR 0.000-0.600 mg\/L - Photometer with Cal kits \u0026 Ccsing - Acorn Scientific","id":25181618275,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nitrit-bis-0600-mgl-1300_1-1_2015.jpeg?v=1443494567"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nitrit-bis-0600-mgl-1300_1-1_2015.jpeg?v=1443494567","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eNitrites are an intermediate product in the nitrogen cycle and are produced by ammonia oxidation with water. or even originate in industrial waste directly. They must not be present in drinking water.\u003c\/p\u003e\u003cp\u003eThe HI 96707 measures the Nitrogen-Nitrite content in the 0.000 to 0.600 mg\/L (ppm) range. in drinking. surface and saline water samples and in domestic and industrial wastes.\u003c\/p\u003e\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96707C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96707_04_07_11.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/ist96707_04_07_11.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.000 to 0.600 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±4% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of an EPA approved method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F);max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e"}
HANNA HI96707C Nitrite LR 0.000-0.600 mg/L - Photometer with Cal kits & Ccsing
Related Products
Biobase PH-210 Benchtop pH meter
$1,229.00 $1,695.00
Carbolite Heating element 200mm long
$799.00 $850.00
Carbolite Thermocouple for AAF11/3
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00














