Email info@acornsci.com for orders and inquiries.

{"id":1582074821,"title":"HANNA HI 96716 Bromine Portable Photometer","handle":"hi96716","description":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eCAL CHECK™\u003c\/li\u003e\n\u003cli\u003eUser calibration\u003c\/li\u003e\n\u003cli\u003eCertified calibration and verification standards\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System)\u003c\/li\u003e\n\u003cli\u003eTIMER function\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"k0b1um0a93_3\" class=\"k0b1um0a93\"\u003eAuto\u003c\/span\u003e shut-off\u003c\/li\u003e\n\u003cli\u003eGLP Features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003eIn many countries. bromine sanitizing has been introduced as an alternative for chlorine. Although it is not as strong as chlorine. bromine remains stable at higher temperatures (advantageous for heated pools and \u003cspan id=\"k0b1um0a93_1\" class=\"k0b1um0a93\"\u003ehot tubs\u003c\/span\u003e). and higher pH levels. Furthermore. it has little reaction to nitrogen compounds. thus reducing the unpleasant odor and eye irritation problems associated with pool water sanitation. The main disadvantage of bromine is the slower acting disinfecting power. making it less suitable for larger pools.\u003c\/p\u003e\n\u003cp\u003eThe HI 96716 meter measures the bromine  content in water samples in the 0.00 to 10.00 mg\/L (ppm) range. The HI 96 series portable photometers use an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHI 96716\u003c\/strong\u003e is supplied with sample cuvettes with caps (2). 9V battery and instruction manual. \u003cbr\u003e\u003cstrong\u003eHI 96716C\u003c\/strong\u003e includes HI 96716 photometer. sample cuvettes and caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eAccessories\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange. FreeChlorine\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L (ppm) ±3% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan id=\"k0b1um0a93_2\" class=\"k0b1um0a93\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater. 20th edition. DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e\u003cspan\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96716_15_12_2010.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/man96716_15_12_2010.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093703-50\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093703-50\"\u003eHI 93703-50\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCuvette Cleaning Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731318\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731318\"\u003eHI 731318\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCuvette Cleaning Cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731331\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731331\"\u003eHI 731331\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGlass Cuvette Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731335\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731335\"\u003eHI 731335\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCuvette Cap for HI 957xx Series Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eReagents \u0026amp; Standards\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2096716-11\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2096716-11\"\u003eHI 96716-11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCAL CHECK™ standard cuvettes (Br2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093716-01\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093716-01\"\u003eHI 93716-01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBromine. DPD Method (100 Tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093716-03\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093716-03\"\u003eHI 93716-03\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBromine. DPD Method (300 Tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:30:03+12:00","created_at":"2015-09-01T15:03:24+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":40660,"price_min":40660,"price_max":40660,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857072965,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96716","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96716 Bromine Portable Photometer","public_title":null,"options":["Default Title"],"price":40660,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-brom-bis-1000-mgl-1326_1-1_2015.jpeg?v=1443494591"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-brom-bis-1000-mgl-1326_1-1_2015.jpeg?v=1443494591","options":["Title"],"media":[{"alt":"HI 96716 Bromine Portable Photometer - Acorn Scientific","id":21268922467,"position":1,"preview_image":{"aspect_ratio":1.028,"height":800,"width":822,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-brom-bis-1000-mgl-1326_1-1_2015.jpeg?v=1443494591"},"aspect_ratio":1.028,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-brom-bis-1000-mgl-1326_1-1_2015.jpeg?v=1443494591","width":822}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eCAL CHECK™\u003c\/li\u003e\n\u003cli\u003eUser calibration\u003c\/li\u003e\n\u003cli\u003eCertified calibration and verification standards\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System)\u003c\/li\u003e\n\u003cli\u003eTIMER function\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"k0b1um0a93_3\" class=\"k0b1um0a93\"\u003eAuto\u003c\/span\u003e shut-off\u003c\/li\u003e\n\u003cli\u003eGLP Features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003eIn many countries. bromine sanitizing has been introduced as an alternative for chlorine. Although it is not as strong as chlorine. bromine remains stable at higher temperatures (advantageous for heated pools and \u003cspan id=\"k0b1um0a93_1\" class=\"k0b1um0a93\"\u003ehot tubs\u003c\/span\u003e). and higher pH levels. Furthermore. it has little reaction to nitrogen compounds. thus reducing the unpleasant odor and eye irritation problems associated with pool water sanitation. The main disadvantage of bromine is the slower acting disinfecting power. making it less suitable for larger pools.\u003c\/p\u003e\n\u003cp\u003eThe HI 96716 meter measures the bromine  content in water samples in the 0.00 to 10.00 mg\/L (ppm) range. The HI 96 series portable photometers use an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHI 96716\u003c\/strong\u003e is supplied with sample cuvettes with caps (2). 9V battery and instruction manual. \u003cbr\u003e\u003cstrong\u003eHI 96716C\u003c\/strong\u003e includes HI 96716 photometer. sample cuvettes and caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eAccessories\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange. FreeChlorine\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L (ppm) ±3% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan id=\"k0b1um0a93_2\" class=\"k0b1um0a93\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater. 20th edition. DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e\u003cspan\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96716_15_12_2010.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/man96716_15_12_2010.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093703-50\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093703-50\"\u003eHI 93703-50\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCuvette Cleaning Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731318\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731318\"\u003eHI 731318\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCuvette Cleaning Cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731331\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731331\"\u003eHI 731331\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGlass Cuvette Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731335\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%20731335\"\u003eHI 731335\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCuvette Cap for HI 957xx Series Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eReagents \u0026amp; Standards\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2096716-11\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2096716-11\"\u003eHI 96716-11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCAL CHECK™ standard cuvettes (Br2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093716-01\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093716-01\"\u003eHI 93716-01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBromine. DPD Method (100 Tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093716-03\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=009001\u0026amp;ProdCode=HI%2093716-03\"\u003eHI 93716-03\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBromine. DPD Method (300 Tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 96716 Bromine Portable Photometer

Product Description
  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features



In many countries. bromine sanitizing has been introduced as an alternative for chlorine. Although it is not as strong as chlorine. bromine remains stable at higher temperatures (advantageous for heated pools and hot tubs). and higher pH levels. Furthermore. it has little reaction to nitrogen compounds. thus reducing the unpleasant odor and eye irritation problems associated with pool water sanitation. The main disadvantage of bromine is the slower acting disinfecting power. making it less suitable for larger pools.

The HI 96716 meter measures the bromine  content in water samples in the 0.00 to 10.00 mg/L (ppm) range. The HI 96 series portable photometers use an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.

 

 

Order Information:
HI 96716 is supplied with sample cuvettes with caps (2). 9V battery and instruction manual. 
HI 96716C includes HI 96716 photometer. sample cuvettes and caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.

  • Specifications
  • Accessories
  • Downloads
Range. FreeChlorine   0.00 to 10.00 mg/L
Resolution   0.01 mg/L
Accuracy   ±0.08 mg/L (ppm) ±3% of reading @ 25°C
Light Source   Tungsten lamp
Light Detector   Silicon photocell with narrow band interference filter @ 525 nm
Power Supply   9V battery
Auto-off   After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)
Method   adaptation of the Standard Methods for the Examination of Water and Wastewater. 20th edition. DPD method
Product Manuals

  Manual: Download

Solutions
HI 93703-50 Cuvette Cleaning Solution
Accessories
HI 731318 Cuvette Cleaning Cloth
HI 731331 Glass Cuvette Set
HI 731335 Cuvette Cap for HI 957xx Series Meters
Reagents & Standards
HI 96716-11 CAL CHECK™ standard cuvettes (Br2)
HI 93716-01 Bromine. DPD Method (100 Tests)
HI 93716-03 Bromine. DPD Method (300 Tests)