{"id":2012147269,"title":"HANNA HI96770C Silica 0-200 mg\/L - Photometer with Cal kits \u0026 Casing","handle":"hi96770c","description":"\u003cp\u003eSilica is found in all natural waters in the dissolved mineral form. Silica is only slightly soluble in water; solubility and therefore the form of silica in water depends on the pH level of the water and on the minerals containing silica in contact with water.\u003c\/p\u003e\u003cp\u003eSilica’s presence in industrial applications is undesirable since it causes scale. In particular. high pressure turbines are highly effected by this factor.\u003c\/p\u003e\u003cp\u003eHeating systems and reverse osmosis plants also require monitoring of silica.\u003c\/p\u003e\u003cp\u003eHI 96770 measures silica (SiO\u003csub\u003e2\u003c\/sub\u003e) content from 0 to 200 mg\/L.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96770C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96770_12_01_11.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/man96770_12_01_11.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 200 mg\/L (as SiO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±5% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003elight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell with narrow band interference filter @ 466 nm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA METHOD 370.1 for drinking. surface and saline waters. domestic and industrial wastes and Standard Method 4500-SiO2 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Shut-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e","published_at":"2026-06-25T15:26:26+12:00","created_at":"2015-09-04T15:10:38+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":63000,"price_min":63000,"price_max":63000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764114437,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96770C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI96770C Silica 0-200 mg\/L - Photometer with Cal kits \u0026 Casing","public_title":null,"options":["Default Title"],"price":63000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015.jpeg?v=1443494604","\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-silikat-bis-200-mgl-1425_1-151d00691c1705_2015.jpeg?v=1443494604"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015.jpeg?v=1443494604","options":["Title"],"media":[{"alt":"HANNA HI96770C Silica 0-200 mg\/L - Photometer with Cal kits \u0026 Casing - Acorn Scientific","id":25182371939,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015.jpeg?v=1443494604"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015.jpeg?v=1443494604","width":800},{"alt":"HANNA HI96770C Silica 0-200 mg\/L - Photometer with Cal kits \u0026 Casing - Acorn Scientific","id":25182404707,"position":2,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-silikat-bis-200-mgl-1425_1-151d00691c1705_2015.jpeg?v=1443494604"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-silikat-bis-200-mgl-1425_1-151d00691c1705_2015.jpeg?v=1443494604","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eSilica is found in all natural waters in the dissolved mineral form. Silica is only slightly soluble in water; solubility and therefore the form of silica in water depends on the pH level of the water and on the minerals containing silica in contact with water.\u003c\/p\u003e\u003cp\u003eSilica’s presence in industrial applications is undesirable since it causes scale. In particular. high pressure turbines are highly effected by this factor.\u003c\/p\u003e\u003cp\u003eHeating systems and reverse osmosis plants also require monitoring of silica.\u003c\/p\u003e\u003cp\u003eHI 96770 measures silica (SiO\u003csub\u003e2\u003c\/sub\u003e) content from 0 to 200 mg\/L.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96770C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96770_12_01_11.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/man96770_12_01_11.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 200 mg\/L (as SiO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±5% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003elight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell with narrow band interference filter @ 466 nm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA METHOD 370.1 for drinking. surface and saline waters. domestic and industrial wastes and Standard Method 4500-SiO2 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Shut-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e"}
HANNA HI96770C Silica 0-200 mg/L - Photometer with Cal kits & Casing
Related Products
Biobase PH-210 Benchtop pH meter
$1,229.00 $1,695.00
Carbolite Heating element 200mm long
$799.00 $850.00
Carbolite Thermocouple for AAF11/3
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00














