{"id":1582071429,"title":"HANNA HI96821 Sodium Chloride - Digital Refractometer Portable","handle":"hi96821","description":"\u003cul\u003e\n\u003cli\u003eIdeal for the analysis of: Salad Dressings, Cheeses, Condiments, Pickles, Canned Foods, Jarred Foods, Milk, Juices, Energy Drinks, Soups, Brines and Whey.\u003c\/li\u003e\n\u003cli\u003eThe dual-level LCD displays measurement and temperature readings simultaneously\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation for accurate measurements\u003c\/li\u003e\n\u003cli\u003eEasy measurement; place a few drops of the sample in the well and press the READ key\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.\u003c\/li\u003e\n\u003cli\u003eIP65 water protection; built to perform under harsh laboratory and field conditions.\u003c\/li\u003e\n\u003cli\u003eQuick. accurate results. readings are displayed in approximately 1.5 seconds.\u003c\/li\u003e\n\u003cli\u003eSingle point calibration with distilled or deionized water\u003c\/li\u003e\n\u003cli\u003eSmall sample size. can be as small as 2 metric drops.\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off after three minutes of non-use\u003c\/li\u003e\n\u003cli\u003eStainless steel sample well. easy to clean and corrosion resistant\u003c\/li\u003e\n\u003cli\u003eABS thermoplastic casing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHANNA offers the HI 96821 digital sodium chloride refractometer to meet the requirements of the food industry. This optical instrument employs the measurement of the refractive index to determine sodium chloride concentration in aqueous solutions used in food preparation. It is not intended for sea water salinity measurements.\u003c\/p\u003e\n\u003cp\u003eThe measurement of refractive index is simple and quick and provides the user an accepted method for NaCl analysis. Samples are measured after a simple user calibration with deionized or distilled water. Within seconds the instrument measures the refractive index of the solution. The digital refractometer eliminates the uncertainty associated with mechanical refractometers and is portable for measurements where you need them.\u003c\/p\u003e\n\u003cp\u003eThe instrument utilizes internationally recognized references for unit conversion and temperature compensation. It can display the measurement of NaCl concentration 4 different ways: g\/100 g. g\/100 mL. specific gravity. and °Baumé.\u003c\/p\u003e\n\u003cp\u003eTemperature (in °C or °F) is displayed simultaneously with the measurement (on 3 of the ranges) on the large dual level display along with icons for Low Power and other helpful message codes.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 96821 supplied with battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96821_28_04_2009.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 g\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 28\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 mL\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 34\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.000 to 1.216\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e°Baumé\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 26\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 80°C (32 to 176°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 g\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 mL\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.001\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e°Baumé\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (0.1°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 g\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 mL\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.002\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e°Baumé\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.3°C (0.5°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic between 10 and 40°C (50 to 104°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eapproximately 1.5 seconds\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Sample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e100 µL (to cover prism totally)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyellow LED\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003estainless steel ring and flint glass prism\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eafter three minutes of non-use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eIP 65\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e9V \/ approximately 5000 readings\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7”) \/ 420 g (14.8 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2017-11-23T09:13:31+13:00","created_at":"2015-09-01T15:02:56+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Category_Electrochemical","Manufacturer_Hanna Instruments","Promotions_Hanna Clearance","Type_Refractometer"],"price":25000,"price_min":25000,"price_max":25000,"available":true,"price_varies":false,"compare_at_price":52000,"compare_at_price_min":52000,"compare_at_price_max":52000,"compare_at_price_varies":false,"variants":[{"id":4857052613,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96821","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI96821 Sodium Chloride - Digital Refractometer Portable","public_title":null,"options":["Default Title"],"price":25000,"weight":0,"compare_at_price":52000,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/digitalrefraktometer-fur-salzgehalt-lebensmittelindustrie-1441_1-1_2015.jpeg?v=1465536201"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/digitalrefraktometer-fur-salzgehalt-lebensmittelindustrie-1441_1-1_2015.jpeg?v=1465536201","options":["Title"],"media":[{"alt":"H I96821 Sodium Chloride - Digital Refractometer Portable - Acorn Scientific","id":21267775587,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/digitalrefraktometer-fur-salzgehalt-lebensmittelindustrie-1441_1-1_2015.jpeg?v=1465536201"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/digitalrefraktometer-fur-salzgehalt-lebensmittelindustrie-1441_1-1_2015.jpeg?v=1465536201","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli\u003eIdeal for the analysis of: Salad Dressings, Cheeses, Condiments, Pickles, Canned Foods, Jarred Foods, Milk, Juices, Energy Drinks, Soups, Brines and Whey.\u003c\/li\u003e\n\u003cli\u003eThe dual-level LCD displays measurement and temperature readings simultaneously\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation for accurate measurements\u003c\/li\u003e\n\u003cli\u003eEasy measurement; place a few drops of the sample in the well and press the READ key\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.\u003c\/li\u003e\n\u003cli\u003eIP65 water protection; built to perform under harsh laboratory and field conditions.\u003c\/li\u003e\n\u003cli\u003eQuick. accurate results. readings are displayed in approximately 1.5 seconds.\u003c\/li\u003e\n\u003cli\u003eSingle point calibration with distilled or deionized water\u003c\/li\u003e\n\u003cli\u003eSmall sample size. can be as small as 2 metric drops.\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off after three minutes of non-use\u003c\/li\u003e\n\u003cli\u003eStainless steel sample well. easy to clean and corrosion resistant\u003c\/li\u003e\n\u003cli\u003eABS thermoplastic casing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHANNA offers the HI 96821 digital sodium chloride refractometer to meet the requirements of the food industry. This optical instrument employs the measurement of the refractive index to determine sodium chloride concentration in aqueous solutions used in food preparation. It is not intended for sea water salinity measurements.\u003c\/p\u003e\n\u003cp\u003eThe measurement of refractive index is simple and quick and provides the user an accepted method for NaCl analysis. Samples are measured after a simple user calibration with deionized or distilled water. Within seconds the instrument measures the refractive index of the solution. The digital refractometer eliminates the uncertainty associated with mechanical refractometers and is portable for measurements where you need them.\u003c\/p\u003e\n\u003cp\u003eThe instrument utilizes internationally recognized references for unit conversion and temperature compensation. It can display the measurement of NaCl concentration 4 different ways: g\/100 g. g\/100 mL. specific gravity. and °Baumé.\u003c\/p\u003e\n\u003cp\u003eTemperature (in °C or °F) is displayed simultaneously with the measurement (on 3 of the ranges) on the large dual level display along with icons for Low Power and other helpful message codes.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 96821 supplied with battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96821_28_04_2009.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 g\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 28\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 mL\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 34\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.000 to 1.216\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e°Baumé\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 26\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 80°C (32 to 176°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 g\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 mL\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.001\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e°Baumé\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (0.1°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 g\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eg\/100 mL\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.002\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e°Baumé\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.3°C (0.5°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic between 10 and 40°C (50 to 104°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eapproximately 1.5 seconds\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Sample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e100 µL (to cover prism totally)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyellow LED\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003estainless steel ring and flint glass prism\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eafter three minutes of non-use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eIP 65\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e9V \/ approximately 5000 readings\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7”) \/ 420 g (14.8 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

HANNA HI96821 Sodium Chloride - Digital Refractometer Portable

Product Description
  • Ideal for the analysis of: Salad Dressings, Cheeses, Condiments, Pickles, Canned Foods, Jarred Foods, Milk, Juices, Energy Drinks, Soups, Brines and Whey.
  • The dual-level LCD displays measurement and temperature readings simultaneously
  • Automatic Temperature Compensation for accurate measurements
  • Easy measurement; place a few drops of the sample in the well and press the READ key
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.
  • IP65 water protection; built to perform under harsh laboratory and field conditions.
  • Quick. accurate results. readings are displayed in approximately 1.5 seconds.
  • Single point calibration with distilled or deionized water
  • Small sample size. can be as small as 2 metric drops.
  • Automatic shut-off after three minutes of non-use
  • Stainless steel sample well. easy to clean and corrosion resistant
  • ABS thermoplastic casing

 

HANNA offers the HI 96821 digital sodium chloride refractometer to meet the requirements of the food industry. This optical instrument employs the measurement of the refractive index to determine sodium chloride concentration in aqueous solutions used in food preparation. It is not intended for sea water salinity measurements.

The measurement of refractive index is simple and quick and provides the user an accepted method for NaCl analysis. Samples are measured after a simple user calibration with deionized or distilled water. Within seconds the instrument measures the refractive index of the solution. The digital refractometer eliminates the uncertainty associated with mechanical refractometers and is portable for measurements where you need them.

The instrument utilizes internationally recognized references for unit conversion and temperature compensation. It can display the measurement of NaCl concentration 4 different ways: g/100 g. g/100 mL. specific gravity. and °Baumé.

Temperature (in °C or °F) is displayed simultaneously with the measurement (on 3 of the ranges) on the large dual level display along with icons for Low Power and other helpful message codes.

 

Order Information:   HI 96821 supplied with battery and instruction manual.

Product Manuals

  Manual: Download

Specification

Range g/100 g 0 to 28
  g/100 mL 0 to 34
  Specific Gravity 1.000 to 1.216
  °Baumé 0 to 26
  Temperature 0 to 80°C (32 to 176°F)
Resolution g/100 g 0.1
  g/100 mL 0.1
  Specific Gravity 0.001
  °Baumé 0.1
  Temperature 0.1°C (0.1°F)
Accuracy (@20°C) g/100 g ±0.2
  g/100 mL ±0.2
  Specific Gravity ±0.002
  °Baumé ±0.2
  Temperature ±0.3°C (0.5°F)
Temperature Compensation   automatic between 10 and 40°C (50 to 104°F)
Measurement Time   approximately 1.5 seconds
Minimum Sample Volume   100 µL (to cover prism totally)
Light Source   yellow LED
Sample Cell   stainless steel ring and flint glass prism
Auto-off   after three minutes of non-use
Enclosure Rating   IP 65
Battery Type / Battery Life   9V / approximately 5000 readings
Dimensions / Weight   192 x 104 x 69 mm (7.6 x 4.1 x 2.7”) / 420 g (14.8 oz.)