{"id":1582071813,"title":"HI 98127 pH\/°C-Tester (0.1 pH resolution) - waterproof","handle":"hi98127","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eHI 98127\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cspan\u003e simultaneously measures pH and temperature with 0.1 resolution. \u003c\/span\u003e\u003cspan\u003eIt is easy to use. fast and accurate. and is therefore ideally suited for routine measurements. \u003c\/span\u003e\u003cspan\u003eWith replaceable electrode.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eDual display of pH and temperature\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eResolution of 0.1 pH\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eEasily replaceable electrode\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eAutomatic calibration and temperature compensation \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eStability indicator for safe values\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eHOLD function to freeze a reading in the display\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eBattery charge indicator and automatic shut-off\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrdering Information : \u003cspan\u003e\u003cspan class=\"goog-text-highlight\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"goog-text-highlight\"\u003eincl tester pH electrode. electrode replacement tool and batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/IST98127_04_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-7_medium.png?11580704866198517246\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eSpecification: \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. at one or two points with two sets of standard buffers (pH 4.01 \/  7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 300 hours of continuous use; auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2016-07-12T14:35:00+12:00","created_at":"2015-09-01T15:03:00+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["brand_Hanna","Manufacturer_Hanna Instruments"],"price":23300,"price_min":23300,"price_max":23300,"available":true,"price_varies":false,"compare_at_price":23300,"compare_at_price_min":23300,"compare_at_price_max":23300,"compare_at_price_varies":false,"variants":[{"id":4857056581,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI98127","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HI 98127 pH\/°C-Tester (0.1 pH resolution) - waterproof","public_title":null,"options":["Default Title"],"price":23300,"weight":0,"compare_at_price":23300,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/31nrgpdohcl_2015.jpeg?v=1443494490"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31nrgpdohcl_2015.jpeg?v=1443494490","options":["Title"],"media":[{"alt":"HI 98127 pH\/°C-Tester (0.1 pH resolution) - waterproof - Acorn Scientific","id":21267939427,"position":1,"preview_image":{"aspect_ratio":1.0,"height":405,"width":405,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31nrgpdohcl_2015.jpeg?v=1443494490"},"aspect_ratio":1.0,"height":405,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31nrgpdohcl_2015.jpeg?v=1443494490","width":405}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eHI 98127\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cspan\u003e simultaneously measures pH and temperature with 0.1 resolution. \u003c\/span\u003e\u003cspan\u003eIt is easy to use. fast and accurate. and is therefore ideally suited for routine measurements. \u003c\/span\u003e\u003cspan\u003eWith replaceable electrode.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eDual display of pH and temperature\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eResolution of 0.1 pH\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eEasily replaceable electrode\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eAutomatic calibration and temperature compensation \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eStability indicator for safe values\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eHOLD function to freeze a reading in the display\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eBattery charge indicator and automatic shut-off\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrdering Information : \u003cspan\u003e\u003cspan class=\"goog-text-highlight\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"goog-text-highlight\"\u003eincl tester pH electrode. electrode replacement tool and batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/IST98127_04_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-7_medium.png?11580704866198517246\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eSpecification: \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. at one or two points with two sets of standard buffers (pH 4.01 \/  7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 300 hours of continuous use; auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

HI 98127 pH/°C-Tester (0.1 pH resolution) - waterproof

Product Description

HI 98127 simultaneously measures pH and temperature with 0.1 resolution. It is easy to use. fast and accurate. and is therefore ideally suited for routine measurements. With replaceable electrode.

  • Dual display of pH and temperature
  • Resolution of 0.1 pH
  • Easily replaceable electrode
  • Automatic calibration and temperature compensation 
  • Stability indicator for safe values
  • HOLD function to freeze a reading in the display
  • Battery charge indicator and automatic shut-off

 

Ordering Information :  incl tester pH electrode. electrode replacement tool and batteries.

 

Specification:

Range pH -2.0 to 16.0 pH
  Temperature -5.0 to 60.0°C / 23.0 to 140.0°F
Resolution pH 0.1 pH
  Temperature 0.1°C / 0.1°F
Accuracy @ 20°C pH ±0.1 pH
  Temperature ±0.5°C / ±1°F
pH Calibration   automatic. at one or two points with two sets of standard buffers (pH 4.01 /  7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
Temperature Compensation   Automatic
Battery Type / Life   1.5V (4) / approximately 300 hours of continuous use; auto-off after 8 minutes of non-use
Environment   -5 to 50°C (23 to 122°F); RH max 100%
Dimensions   163 x 40 x 26 mm (6.4 x 1.6 x 1.0")
Weight   100 g (3.5 oz.)