Email info@acornsci.com for orders and inquiries.

{"id":1582157061,"title":"HANNA HI98143-20 pH and EC Transmitter with Galvanic Isolated Output 4-20 mA Output","handle":"hi98143-20","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAccepts pH electrode and EC probe signals simultaneously\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDirect probe connection; Assures a positive electrical connection eliminating signal loss\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAutomatic Temperature Compensation (EC only)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eThe HI 98143 series is designed to accept signals directly from a pH electrode and a conductivity probe at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDirect connection of the probes to the transmitter assure a positive electrical connection with no signal loss. This transmitter is ideal for remote process control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eFour models are available. transmitting a 0-1 V. 0-4 V or 4-20 mA signal. The output signals are proportional to the input signals but independent of changes in load or cable capacitance. Compensation for the effects of temperature for EC measurements are performed by the transmitters’ Automatic Temperature Compenstion circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eThe transmitter can be connected to any pH or conductivity controller. recorder. PC or any data monitoring device that accepts 0 to 1 V. 0 to 4 V or 4 to 20 mA input. HI?98143 is an ideal tool for applications that require the monitoring of both pH and conductivity at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eOrder Information:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAll HI 98143 models are supplied with instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TabbedPanels\" id=\"TabbedPanels1\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eSpecifications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAccessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDownloads\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e0 to 14 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEC\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e0 to 10 mS\/cm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAccuracy @ 20°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e±0.5% f.s.\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEC\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e±2% f.s.\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eCalibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003emanual. 2 point. through offset and slope trimmers\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEC\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003emanual. 2 point. through 0 and 5 mS\/cm trimmers\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eTemperature\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eCompensation (EC)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eautomatic. 0 to 60°C (32 to 132°F) with ß=2%\/°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eOutput (isolated)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e4-20 mA\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003epH Electrode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eHI 1001 pH electrode (suggested. not included). HI 1283 matching pin (not included)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEC Probe\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eHI 3001 (not included) with cell constant 2.1\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eCasing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eIP 54\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e12-24 VDC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEnvironment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e160 x 105 x 31 mm (6.3 x 4.1 x 1.2’’)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e280 g (9.9 oz.)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSolutions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207004\/1L\"\u003eHI 7004\/1L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4.01 pH Buffer Solution\u003cbr\u003e1 x 1 L bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207007\/1L\"\u003eHI 7007\/1L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.01 pH Buffer Solution\u003cbr\u003e1 x 1 L bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207010\/1L\"\u003eHI 7010\/1L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10.01 pH Buffer Solution\u003cbr\u003e1 x 1 L bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207039L\"\u003eHI 7039L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessories\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207855\/1\"\u003eHI 7855\/1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection Cable with Screw and BNC Connectors. 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%203001\"\u003eHI 3001\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow-thru Conductivity Probe with 3 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eProduct Manuals\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_98143-01-04-20-22.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDownload\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2017-11-22T09:55:11+13:00","created_at":"2015-09-01T15:14:32+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Category_Electrochemical","Manufacturer_Hanna Instruments","Promotions_Hanna Clearance","Type_pH \u0026 ORP Meters"],"price":50000,"price_min":50000,"price_max":50000,"available":true,"price_varies":false,"compare_at_price":109700,"compare_at_price_min":109700,"compare_at_price_max":109700,"compare_at_price_varies":false,"variants":[{"id":4857282309,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI98143-20","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI98143-20 pH and EC Transmitter with Galvanic Isolated Output 4-20 mA Output","public_title":null,"options":["Default Title"],"price":50000,"weight":0,"compare_at_price":109700,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e845611f70b_2015_09adfb90-1fa7-4432-86fd-415b226a16d7.jpeg?v=1443495506"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e845611f70b_2015_09adfb90-1fa7-4432-86fd-415b226a16d7.jpeg?v=1443495506","options":["Title"],"media":[{"alt":null,"id":21296054371,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e845611f70b_2015_09adfb90-1fa7-4432-86fd-415b226a16d7.jpeg?v=1443495506"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e845611f70b_2015_09adfb90-1fa7-4432-86fd-415b226a16d7.jpeg?v=1443495506","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAccepts pH electrode and EC probe signals simultaneously\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDirect probe connection; Assures a positive electrical connection eliminating signal loss\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAutomatic Temperature Compensation (EC only)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eThe HI 98143 series is designed to accept signals directly from a pH electrode and a conductivity probe at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDirect connection of the probes to the transmitter assure a positive electrical connection with no signal loss. This transmitter is ideal for remote process control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eFour models are available. transmitting a 0-1 V. 0-4 V or 4-20 mA signal. The output signals are proportional to the input signals but independent of changes in load or cable capacitance. Compensation for the effects of temperature for EC measurements are performed by the transmitters’ Automatic Temperature Compenstion circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eThe transmitter can be connected to any pH or conductivity controller. recorder. PC or any data monitoring device that accepts 0 to 1 V. 0 to 4 V or 4 to 20 mA input. HI?98143 is an ideal tool for applications that require the monitoring of both pH and conductivity at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eOrder Information:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAll HI 98143 models are supplied with instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TabbedPanels\" id=\"TabbedPanels1\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eSpecifications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAccessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDownloads\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e0 to 14 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEC\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e0 to 10 mS\/cm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eAccuracy @ 20°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e±0.5% f.s.\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEC\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e±2% f.s.\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eCalibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003emanual. 2 point. through offset and slope trimmers\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEC\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003emanual. 2 point. through 0 and 5 mS\/cm trimmers\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eTemperature\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eCompensation (EC)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eautomatic. 0 to 60°C (32 to 132°F) with ß=2%\/°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eOutput (isolated)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e4-20 mA\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003epH Electrode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eHI 1001 pH electrode (suggested. not included). HI 1283 matching pin (not included)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEC Probe\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eHI 3001 (not included) with cell constant 2.1\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eCasing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eIP 54\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e12-24 VDC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eEnvironment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e160 x 105 x 31 mm (6.3 x 4.1 x 1.2’’)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e280 g (9.9 oz.)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSolutions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207004\/1L\"\u003eHI 7004\/1L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4.01 pH Buffer Solution\u003cbr\u003e1 x 1 L bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207007\/1L\"\u003eHI 7007\/1L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.01 pH Buffer Solution\u003cbr\u003e1 x 1 L bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207010\/1L\"\u003eHI 7010\/1L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10.01 pH Buffer Solution\u003cbr\u003e1 x 1 L bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207039L\"\u003eHI 7039L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessories\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%207855\/1\"\u003eHI 7855\/1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection Cable with Screw and BNC Connectors. 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=034006\u0026amp;ProdCode=HI%203001\"\u003eHI 3001\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow-thru Conductivity Probe with 3 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eProduct Manuals\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003e  Manual: \u003c\/span\u003e\u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_98143-01-04-20-22.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cspan class=\"remarkable-pre-marked\"\u003eDownload\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI98143-20 pH and EC Transmitter with Galvanic Isolated Output 4-20 mA Output

Product Description

 

 

  • Accepts pH electrode and EC probe signals simultaneously
  • Direct probe connection; Assures a positive electrical connection eliminating signal loss
  • Automatic Temperature Compensation (EC only)

 

The HI 98143 series is designed to accept signals directly from a pH electrode and a conductivity probe at the same time.

Direct connection of the probes to the transmitter assure a positive electrical connection with no signal loss. This transmitter is ideal for remote process control applications.

Four models are available. transmitting a 0-1 V. 0-4 V or 4-20 mA signal. The output signals are proportional to the input signals but independent of changes in load or cable capacitance. Compensation for the effects of temperature for EC measurements are performed by the transmitters’ Automatic Temperature Compenstion circuitry.

The transmitter can be connected to any pH or conductivity controller. recorder. PC or any data monitoring device that accepts 0 to 1 V. 0 to 4 V or 4 to 20 mA input. HI?98143 is an ideal tool for applications that require the monitoring of both pH and conductivity at the same time.

 

 

Order Information:
All HI 98143 models are supplied with instructions.

  • Specifications
  • Accessories
  • Downloads
Range pH 0 to 14 pH
  EC 0 to 10 mS/cm
Accuracy @ 20°C pH ±0.5% f.s.
  EC ±2% f.s.
Calibration pH manual. 2 point. through offset and slope trimmers
  EC manual. 2 point. through 0 and 5 mS/cm trimmers
Temperature
Compensation (EC)
  automatic. 0 to 60°C (32 to 132°F) with ß=2%/°C
Output (isolated)   4-20 mA
pH Electrode   HI 1001 pH electrode (suggested. not included). HI 1283 matching pin (not included)
EC Probe   HI 3001 (not included) with cell constant 2.1
Casing   IP 54
Power Supply   12-24 VDC
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   160 x 105 x 31 mm (6.3 x 4.1 x 1.2’’)
Weight   280 g (9.9 oz.)
Solutions
HI 7004/1L 4.01 pH Buffer Solution
1 x 1 L bottle
HI 7007/1L 7.01 pH Buffer Solution
1 x 1 L bottle
HI 7010/1L 10.01 pH Buffer Solution
1 x 1 L bottle
HI 7039L 5000 µS/cm EC Solution. 500 mL Bottle
Accessories
HI 7855/1 Connection Cable with Screw and BNC Connectors. 1 m
Probes
HI 3001 Flow-thru Conductivity Probe with 3 m cable
Product Manuals

  Manual: Download

$500.00 $1,097.00
Maximum quantity available reached.
Liquid error (layout/theme line 139): Could not find asset snippets/beae_footer.liquid