{"id":1582175493,"title":"HANNA HI 98290-02 GPS Multiparameter Meter","handle":"hi98290-02","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eField replaceable ISO 7027 compliant turbidity sensor\u003c\/li\u003e\n\u003cli\u003eAmmonium. chloride and nitrate ISE’s\u003c\/li\u003e\n\u003cli\u003eLogging from probe or meter\u003c\/li\u003e\n\u003cli\u003eFully customizable instrument. probe. sensors and measurement specifications\u003c\/li\u003e\n\u003cli\u003eDisplay from 1 to 12 parameters with font dimension adjustment\u003c\/li\u003e\n\u003cli\u003eField replaceable sensors\u003c\/li\u003e\n\u003cli\u003epH\/ORP or pH. four electrode EC and galvanic DO sensors\u003c\/li\u003e\n\u003cli\u003eAuto-recognition of all sensors\u003c\/li\u003e\n\u003cli\u003eRugged probe with stainless steel tip has a diameter under 2” for wells and pipes\u003c\/li\u003e\n\u003cli\u003eTrack measurement locations with GPS\u003c\/li\u003e\n\u003cli\u003eFast Tracker™—Tag I.D. System simplifies periodic monitoring\u003c\/li\u003e\n\u003cli\u003eFeatures a built-in barometer for DO compensation\u003c\/li\u003e\n\u003cli\u003eQuick or independent sensor calibration feature\u003c\/li\u003e\n\u003cli\u003eMeasurement check eliminates erroneous readings\u003c\/li\u003e\n\u003cli\u003eLogged data can be displayed as graphs\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with backlight\u003c\/li\u003e\n\u003cli\u003eUSB for PC connectivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"b63hrm70_1\" class=\"b63hrm70\"\u003eGood Laboratory Practice\u003c\/span\u003e feature with last five calibrations recorded\u003c\/li\u003e\n\u003cli\u003eMeter accepts both alkaline and rechargeable batteries\u003c\/li\u003e\n\u003cli\u003eWaterproof protection for meter (IP67) and probes (IP 68)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eRugged. waterproof and easy to use. the HI 98290 is the ideal meters for \u003cspan id=\"b63hrm70_3\" class=\"b63hrm70\"\u003efield measurements\u003c\/span\u003e of lakes. rivers and seas. Both meters display 1 to 12 parameters simultaneously from up to 15 user selectable parameters.\u003c\/p\u003e\n\u003cp\u003eCombined with one of the HI 76x9829 series probes. the HI 98290 can measure water quality parameters such as pH. ORP. conductivity. turbidity. temperature. ions ions ammonium. nitrate. chloride (NH\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e+\u003c\/sup\u003e. NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e—N or Cl\u003csup\u003e-\u003c\/sup\u003e). \u003cspan id=\"b63hrm70_2\" class=\"b63hrm70\"\u003edissolved oxygen\u003c\/span\u003econcentration. resistivity. TDS. salinity. and seawater specific gravity. Atmospheric pressure is measured for DO compensation.\u003c\/p\u003e\n\u003cp\u003eThe HI 98290 with the GPS option incorporates a built-in GPS receiver and antenna that guarantees position accuracy. Measurements from specific locations are tracked with detailed coordinate information that can be viewed immediately on the display.\u003c\/p\u003e\n\u003cp\u003eThis meter features a graphic. backlit LCD that scales digits to fit up to 12 parameters and allows full configuration of each parameter measured along with an on-screen graphing capability.\u003c\/p\u003e\n\u003cp\u003eHI 98290 incorporates comprehensive GLP features and the transferring of data via USB connection. The HI 98290’s HELP key displays context sensitive help. The alpha-numeric keypad offers a user friendly way to complete the input fields.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eThe Perfect Monitoring Tool\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eWater scientists and managers alike utilize data-collection programs as part of environmental monitoring. These programs are designed to reveal changes in water and the environment around it over time. Reliable. dependable measurements are required to monitor these changes and understand the contributions from seasonal fluctuations. weathering. as well as manmade pollution. The HI 7629829 or HI 7639829 intelligent autonomously logging probes can be left at the application site to autonomously log results without the aid of the HI 98290 or a PC. When it is time to retrieve the results the measurement data can be easily transferred to the meters or PC using HI 929829 software.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eSensors\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eSensor replacement is quick and easy with screw type connectors and color coded sensors. The HI 98290 automatically recognizes sensor presence.\u003c\/p\u003e\n\u003cp\u003eThe HI 7609829-2 galvanic DO sensor with its fast response time can be ready at a moment’s notice. This probe features a replaceable membrane cap for easy maintenance.\u003c\/p\u003e\n\u003cp\u003eThe HI 7609829-3 4-electrode conductivity probe uses a polarographic measurement principle and ensures stable conductivity readings that are immune to polarization or surface coating. Absolute conductivity. temperature compensated conductivity. salinity. specific gravity and TDS determinations are possible with measurements from this sensor.\u003c\/p\u003e\n\u003cp\u003eThe new HI 7609829-4 EC\/turbidity sensor is field replaceable and offers readings from both parameters at the same time.\u003c\/p\u003e\n\u003cp\u003eAll potentiometric sensors feature a double junction design and are gel filled to increase resistance to contamination. An ISE sensor can be used in place of the pH sensor and is automatically recognized. pH in mV readings are also displayed —ideal for troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eA Great Combination\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe use of HANNA’s microprocessor based multiparameter intelligent probes with HI 98290 meter will provide reliable data collection that can lead to an improved scientific understanding of the interconnections between natural. chemical and geological processes and man made pollution to effectively evaluate applications for waste-discharge permits. remediate contaminated sites and to protect or restore biological resources.\u003c\/p\u003e\n\u003cp\u003eThe HI 76x9829 probes utilize field replaceable sensors with auto-recognition. The sensors are housed with the probe electronics in a rugged housing with a water-tight cable connection. The base probe model permits the measurement of conductivity. pH\/ORP (or an ISE). and dissolved oxygen. Other models permit turbidity and logging.\u003c\/p\u003e\n\u003cp\u003eThe probes are available with a choice of cable lengths such as 4 m and 10 m and 20 m (13. 33’) that utilize a DIN connection to interface with the meters. The probes are supplied with a maintenance kit in the carrying case versions. These new probes can be connected directly to a PC with the HI 96982910 USB adapter. and the HI 929829 PC software to communicate directly with the probes.\u003c\/p\u003e\n\u003cp\u003eReliable temperature measurements are a critical parameter of aquatic system monitoring. Temperature and temperature changes due to water releases can affect the ability of water to hold oxygen as well as the ability of organisms to resist certain pollutants. The intelligent probes incorporate an accurate thermistor that changes predictably with temperature changes. Accurate temperature reading in degrees Celsius. Kelvin or Fahrenheit are displayed and utilized by other detectors for temperature correction.\u003c\/p\u003e\n\u003cp\u003eThe pH or pH\/ORP sensors incorporate the technology that has made HANNA so successful as a pH manufacturer. Reliable pH measurements are one of the most important indicators of water chemistry indicating the relative amount of free hydrogen and hydroxyl ions in the water. HANNA’s pH sensors utilize a resilient PEI body to protect them from solid particulates found water samples. Consistency and quality are the hallmarks of these sensors. Our differential measurement system further enhances the measurement reliability providing temperature corrected pH.\u003c\/p\u003e\n\u003cp\u003eA choice of 3 ion selective electrodes is available for constant reporting of common surface water contaminants. Nitrate. ammonium and chloride are available. Each ISE is a combination electrode incorporating an extremely constant reference spiral; all potentionmetric probes feature a double junction and solid gelled reference design. By utilizing conductivity. the HI 98290 can convert ion activity measurements to concentration units. \u003c\/p\u003e\n\u003cp\u003eThe HANNA 4-electrode conductivity probe using the polarographic measurement principal ensures stable conductivity readings. Electrolytic conductivity measures of the ability of water to conduct an electrical current. It is highly dependent on the amount of dissolved solids (such as salt) in the water. Absolute conductivity. temperature corrected conductivity. salinity. specific gravity and water hardness (TDS) determinations are possible with measurements from this sensor.\u003c\/p\u003e\n\u003cp\u003eThe oxygen dissolved in lakes. rivers. and oceans is crucial for the organisms and creatures living in it. If dissolved oxygen concentrations drop below normal levels in water bodies. the water quality degrades and the organisms begin to die off. The galvanic sensor does not require long polarization times so is ready for measurement at a moment’s notice. Our sensor also utilizes a replaceable cap design for ease of maintenance and a safe non-toxic electrolyte. DO readings are compensated for the effects of temperature (using the probes built-in temperature sensor) and atmospheric pressure (using the HI 98290’s internal atmospheric pressure sensor).\u003c\/p\u003e\n\u003cp\u003eThe new HANNA turbidity sensor is a replaceable design for instantaneous turbidity reading that conforms to ISO 7027 standards. It provides measurements from 0.0 to 50.0 FNU; and 50 to 1000 FNU. Turbidity is the amount of particulate matter that is suspended in water. Turbidity measures the scattering effect that suspended solids have on light: the higher the intensity of scattered light. the higher the turbidity. Material that causes water to be turbid include: clay. silt. finely divided organic and inorganic matter. soluble colored organic compounds. plankton and microscopic organisms.\u003c\/p\u003e\n\u003cp\u003eProbes with the logging function have a logging memory that allows storage of up to 140.000 individual samples or 12.000 complete sample data sets with date and time stamp thus permitting up to a 35 day deployment with all channels logging at 10 minute intervals. Logging probes work with either rechargeable or standard batteries\u003c\/p\u003e\n\u003cp\u003eThe probe incorporates a temperature sensor for temperature compensation of all parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eMonitoring and Tracking\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eWhen data collection or monitoring requires tracking capabilities. two kinds of methods can be included with the data—timestamp and location. The timestamp expresses the date and the time when the measurement was taken. The time and date (timestamp) are determined by the internal real time clock of the HI 98290. As for location of measurement. the HI 98290 offers two solutions. One is GPS tracking using the HI 98290’s internal 12 channel GPS receiver. The second is the FastTracker™ Tag ID system using ID encoded TAGs mounted at the location sites. Users simply touch the TAG receiver to the mounted TAG to store data along with location ID.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eGPS (Global Positioning System) Enabled\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe new HI 98290 features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data. The GPS tracks your location using satellites to within 30 ft (10 m) so you can be sure that you return to the same location for repeated measurements.\u003c\/p\u003e\n\u003cp\u003eUsers can connect to GPS tracking software such as Google™ Maps* to view locations where samples have been taken. Measurement information is shown right on the map.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eFast Tracker™—Tag Identification System\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eHANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButton®s with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button. measurements are logged and labeled with the alphanumeric user-entered location ID. Location. date. time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eiButton\u003csup\u003e®\u003c\/sup\u003e Tags are Easy to Install\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eInstall the optional TAGs near your sampling points for quick and easy iButton® readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003e*Google™ is a registered trademark of Google™. inc. HANNA Instruments® has no affiliation with Google™.\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eChoose your configuration -\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMETER ONLY. CARTON BOX PACKAGING\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHI 98290-01\u003c\/strong\u003e Meter only with GPS enabled. charging adapter and instruction manual. 115VAC \u003cbr\u003e\u003cstrong\u003eHI 98290-02\u003c\/strong\u003e Meter only with GPS enabled. charging adapter and instruction manual. 230VAC \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETER AND PROBE ONLY. NO SENSORS. CARRYING CASE PACKAGING\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHI 98295-01\u003c\/strong\u003e HI 98290 with GPS and HI 7629829\/4 logging probe for pH\/pH+ORP\/ISE. DO. EC. temperature. with 4 m (13.1’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 115VAC\u003cbr\u003e\u003cstrong\u003eHI 98295-02\u003c\/strong\u003e HI 98290 with GPS and HI 7629829\/4 logging probe for pH\/pH+ORP\/ISE. DO. EC. temperature. with 4 m (13.1’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 230VAC\u003cbr\u003e\u003cstrong\u003eHI 98296-01\u003c\/strong\u003e HI 98290 with GPS and HI 7639829\/4 logging probe for pH\/pH+ORP\/ISE. DO. EC+turbidity. temperature. with 4 m (13.1’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 115VAC\u003cbr\u003e\u003cstrong\u003eHI 98296-02\u003c\/strong\u003e HI 98290 with GPS and HI 7639829\/4 logging probe for pH\/pH+ORP\/ISE. DO. EC+turbidity. temperature. with 4 m (13.1’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 230VAC\u003cbr\u003e\u003cstrong\u003eHI 98297-01\u003c\/strong\u003e HI 98290 with GPS and HI 7629829\/10 logging probe for pH\/pH+ORP\/ISE. DO. EC. temperature. with 10 m (33’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 115VAC\u003cbr\u003e\u003cstrong\u003eHI 98297-02\u003c\/strong\u003e HI 98290 with GPS and HI 7629829\/10 logging probe for pH\/pH+ORP\/ISE. DO. EC. temperature. with 10 m (33’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 230VAC\u003cbr\u003e\u003cstrong\u003eHI 98298-01\u003c\/strong\u003e HI 98290 with GPS and HI 7639829\/10 logging probe for pH\/pH+ORP\/ISE. DO. EC+turbidity. temperature. with 10 m (33’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 115VAC\u003cbr\u003e\u003cstrong\u003eHI 98298-02\u003c\/strong\u003e HI 98290 with GPS and HI 7639829\/10 logging probe for pH\/pH+ORP\/ISE. DO. EC+turbidity. temperature. with 10 m (33’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 230VAC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eSensors for all meter and probe configurations are sold separately. see configurations up above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003epH\/mV of pH input\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 14.00 pH \/ ±600.0 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eORP mV\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2000.0 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAmmonium-\u003cbr\u003eNitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.02 to 200 ppm (as N)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eChloride\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.6 to 200 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNitrate-Nitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.62 to 200 ppm (as N)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eConductivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 200 mS\/cm (absolute EC up to 400 mS\/cm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 400000 mg\/L or ppm (the maximum value depends on the TDS factor)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eResistivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 70.00 PSU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSeawater σ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50.0 σ\u003csub\u003et\u003c\/sub\u003e. σ\u003csub\u003e0\u003c\/sub\u003e. σ\u003csub\u003e15\u003c\/sub\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 99.9 FNU; 100 to 1000 FNU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 500.0%; 0.00 to 50.00 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAtm. Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003epH\/mV of pH input\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 pH \/ 0.1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eORP mV\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAmmonium-\u003cbr\u003eNitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eChloride\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNitrate-Nitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eConductivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cem\u003emanual:\u003c\/em\u003e 1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm; \u003cem\u003eautomatic:\u003c\/em\u003e 1 µS\/cm from 0 to 9999 µS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm; \u003cem\u003eautomatic mS\/cm:\u003c\/em\u003e 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cem\u003emanual:\u003c\/em\u003e 1 mg\/L (ppm); 0.001 g\/L (ppt); 0.01g\/L (ppt); 0.1 g\/L (ppt); 1 g\/L (ppt); \u003cem\u003eautorange scales:\u003c\/em\u003e 1 mg\/L (ppm) from 0 to 9999 mg\/L (ppm); 0.01 g\/L (ppt) from 10.00 to 99.99 g\/L (ppt); 0.1 g\/L (ppt) from 100.0 to 400.0 g\/L (ppt); \u003cem\u003eautorange g\/L (ppt) scales:\u003c\/em\u003e 0.001 g\/L (ppt) from 0.000 to 9.999 g\/L (ppt); 0.01 g\/L (ppt) from 10.00 to 99.99 g\/L (ppt); 0.1 g\/L (ppt) from 100.0 to 400.0 g\/L (ppt)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eResistivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edependent on resistivity reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 PSU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSeawater σ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 σ\u003csub\u003et\u003c\/sub\u003e. σ\u003csub\u003e0\u003c\/sub\u003e. σ\u003csub\u003e15\u003c\/sub\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 FNU from 0.0 to 99.9 FNU; 1 FNU from 100 to 1000 FNU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1%; 0.01 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAtm. Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01°C; 0.01°F; 0.01K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003epH\/mV of pH input\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.02 pH \/ ±0.5 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eORP mV\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.0 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAmmonium-\u003cbr\u003eNitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±5% of reading or 2 ppm. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eChloride\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±5% of reading or 2 ppm. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNitrate-Nitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±5% of reading or 2 ppm. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eConductivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading or ±1 µS\/cm. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading or ±1 mg\/L. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2% of reading or ±0.01 PSU. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSeawater σ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1 σ\u003csub\u003et\u003c\/sub\u003e. σ\u003csub\u003e0\u003c\/sub\u003e. σ\u003csub\u003e15\u003c\/sub\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.3 FNU or ±2% of reading. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm: ±1.5% of reading or 0.10 ppm. whichever is greater; 30.00 ppm to 50.00 ppm: ±3% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAtm. Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±3 mm Hg within ±15°C from the temperature during calibration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.15°C; ±0.27°F; ±0.15K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from -5 to 55°C (23 to 131°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGPS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e12 channel receiver\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Memory\u003cbr\u003efrom Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e44.000 records\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 second to 3 hours\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComputer Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eUSB (with HI 929829 software)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastTracker™ TAG ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyes\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaterproof Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eIP67\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V alkaline C cells (4) \/ 1.2V NiMH rechargeable C cells (4). USB. 12V power adapter\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e750g (26.5 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eACCESSORIES\u003c\/h2\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-16\"\u003eHI 9829-16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTurbidity Calibration Solution. 0 FNU. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-17\"\u003eHI 9829-17\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTurbidity Calibration Solution. 20 FNU. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-18\"\u003eHI 9829-18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTurbidity Calibration Solution. 200 FNU. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20929829\"\u003eHI 929829\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePC Application Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698291\"\u003eHI 7698291\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Cable. PC to Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%2076982910\"\u003eHI 76982910\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB cable. PC to Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20710046\"\u003eHI 710046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLighter Cigarette Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698290\"\u003eHI 7698290\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShort Calibration Beaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698293\"\u003eHI 7698293\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLong Calibration Beaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698294\"\u003eHI 7698294\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShort Flow Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698297\"\u003eHI 7698297\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLong. Quick Release Flow Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698295\"\u003eHI 7698295\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShort Protective Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698296\"\u003eHI 7698296\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLong Protective Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20920005\"\u003eHI 920005\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eiButton\u003csup\u003e®\u003c\/sup\u003e Tags\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20710140\"\u003eHI 710140\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eHard Carrying Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20710045\"\u003eHI 710045\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eReagents \u0026amp; Standards\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-10\/11\"\u003eHI 9829-10\/11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eISE Standards Kit for HI 7609829-10. 10 Sachets ea.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-10\"\u003eHI 9829-10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ppm Standard Sachets for HI 7609829-10 Ammonium ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-11\"\u003eHI 9829-11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ppm Standard Sachet for HI 7609829-10 Ammonium ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-12\/13\"\u003eHI 9829-12\/13\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eISE Standards kit for HI 7609829-11 Chloride ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-12\"\u003eHI 9829-12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ppm Standard Sachets for HI 7609829-11 Chloride ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-13\"\u003eHI 9829-13\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ppm Standard Sachet for HI 7609829-11 Chloride ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-14\/15\"\u003eHI 9829-14\/15\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eISE Standards for 7609829-12 Nitrate ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-14\"\u003eHI 9829-14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ppm Standard Sachets for HI 7609829-12 Nitrate ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-15\"\u003eHI 9829-15\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ppm Standard Sachets for HI 7609829-12 Nitrate ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-0\"\u003eHI 7609829-0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-1\"\u003eHI 7609829-1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH\/ORP Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-2\"\u003eHI 7609829-2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-3\"\u003eHI 7609829-3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-4\"\u003eHI 7609829-4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\/Turbidity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-10\"\u003eHI 7609829-10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAmmonium ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-11\"\u003eHI 7609829-11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eChloride ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-12\"\u003eHI 7609829-12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNitrate ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eQuick Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209828-27\"\u003eHI 9828-27\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eQuick Calibration Solution. 1 Gallon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209828-25\"\u003eHI 9828-25\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eQuick Calibration Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003epH Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207010L\"\u003eHI 7010L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207007L\"\u003eHI 7007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207004L\"\u003eHI 7004L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eORP Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207022L\"\u003eHI 7022L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eORP Test Solution at 470 mV @ 25°C\/77°F)\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207021L\"\u003eHI 7021L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eORP Test Solution at (240 mV @ 25°C\/77°F)\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eDissolved Oxygen Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207042S\"\u003eHI 7042S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution for Galvanic Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eConductivity Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207039L\"\u003eHI 7039L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207035L\"\u003eHI 7035L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e111800 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207034L\"\u003eHI 7034L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e80000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207033L\"\u003eHI 7033L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e84 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207031L\"\u003eHI 7031L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207030L\"\u003eHI 7030L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12880 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eCleaning and Maintenance Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207061L\"\u003eHI 7061L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Cleaning Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e \u003c\/h2\u003e","published_at":"2026-06-25T16:09:31+12:00","created_at":"2015-09-01T15:16:55+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters","Type_pH \u0026 ORP Meters","Type_Thermometers"],"price":340000,"price_min":340000,"price_max":340000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":6528952261,"title":"230V","option1":"230V","option2":null,"option3":null,"sku":"HI98290-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 98290-02 GPS Multiparameter Meter - 230V","public_title":"230V","options":["230V"],"price":340000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":6528952325,"title":"115V","option1":"115V","option2":null,"option3":null,"sku":null,"requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 98290-02 GPS Multiparameter Meter - 115V","public_title":"115V","options":["115V"],"price":340000,"weight":0,"compare_at_price":null,"inventory_quantity":2,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi98290_200_2015.jpeg?v=1443495742"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi98290_200_2015.jpeg?v=1443495742","options":["Title"],"media":[{"alt":"HANNA HI 98290-02 GPS Multiparameter Meter - Acorn Scientific","id":21303394403,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi98290_200_2015.jpeg?v=1443495742"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi98290_200_2015.jpeg?v=1443495742","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eField replaceable ISO 7027 compliant turbidity sensor\u003c\/li\u003e\n\u003cli\u003eAmmonium. chloride and nitrate ISE’s\u003c\/li\u003e\n\u003cli\u003eLogging from probe or meter\u003c\/li\u003e\n\u003cli\u003eFully customizable instrument. probe. sensors and measurement specifications\u003c\/li\u003e\n\u003cli\u003eDisplay from 1 to 12 parameters with font dimension adjustment\u003c\/li\u003e\n\u003cli\u003eField replaceable sensors\u003c\/li\u003e\n\u003cli\u003epH\/ORP or pH. four electrode EC and galvanic DO sensors\u003c\/li\u003e\n\u003cli\u003eAuto-recognition of all sensors\u003c\/li\u003e\n\u003cli\u003eRugged probe with stainless steel tip has a diameter under 2” for wells and pipes\u003c\/li\u003e\n\u003cli\u003eTrack measurement locations with GPS\u003c\/li\u003e\n\u003cli\u003eFast Tracker™—Tag I.D. System simplifies periodic monitoring\u003c\/li\u003e\n\u003cli\u003eFeatures a built-in barometer for DO compensation\u003c\/li\u003e\n\u003cli\u003eQuick or independent sensor calibration feature\u003c\/li\u003e\n\u003cli\u003eMeasurement check eliminates erroneous readings\u003c\/li\u003e\n\u003cli\u003eLogged data can be displayed as graphs\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with backlight\u003c\/li\u003e\n\u003cli\u003eUSB for PC connectivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"b63hrm70_1\" class=\"b63hrm70\"\u003eGood Laboratory Practice\u003c\/span\u003e feature with last five calibrations recorded\u003c\/li\u003e\n\u003cli\u003eMeter accepts both alkaline and rechargeable batteries\u003c\/li\u003e\n\u003cli\u003eWaterproof protection for meter (IP67) and probes (IP 68)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eRugged. waterproof and easy to use. the HI 98290 is the ideal meters for \u003cspan id=\"b63hrm70_3\" class=\"b63hrm70\"\u003efield measurements\u003c\/span\u003e of lakes. rivers and seas. Both meters display 1 to 12 parameters simultaneously from up to 15 user selectable parameters.\u003c\/p\u003e\n\u003cp\u003eCombined with one of the HI 76x9829 series probes. the HI 98290 can measure water quality parameters such as pH. ORP. conductivity. turbidity. temperature. ions ions ammonium. nitrate. chloride (NH\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e+\u003c\/sup\u003e. NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e—N or Cl\u003csup\u003e-\u003c\/sup\u003e). \u003cspan id=\"b63hrm70_2\" class=\"b63hrm70\"\u003edissolved oxygen\u003c\/span\u003econcentration. resistivity. TDS. salinity. and seawater specific gravity. Atmospheric pressure is measured for DO compensation.\u003c\/p\u003e\n\u003cp\u003eThe HI 98290 with the GPS option incorporates a built-in GPS receiver and antenna that guarantees position accuracy. Measurements from specific locations are tracked with detailed coordinate information that can be viewed immediately on the display.\u003c\/p\u003e\n\u003cp\u003eThis meter features a graphic. backlit LCD that scales digits to fit up to 12 parameters and allows full configuration of each parameter measured along with an on-screen graphing capability.\u003c\/p\u003e\n\u003cp\u003eHI 98290 incorporates comprehensive GLP features and the transferring of data via USB connection. The HI 98290’s HELP key displays context sensitive help. The alpha-numeric keypad offers a user friendly way to complete the input fields.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eThe Perfect Monitoring Tool\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eWater scientists and managers alike utilize data-collection programs as part of environmental monitoring. These programs are designed to reveal changes in water and the environment around it over time. Reliable. dependable measurements are required to monitor these changes and understand the contributions from seasonal fluctuations. weathering. as well as manmade pollution. The HI 7629829 or HI 7639829 intelligent autonomously logging probes can be left at the application site to autonomously log results without the aid of the HI 98290 or a PC. When it is time to retrieve the results the measurement data can be easily transferred to the meters or PC using HI 929829 software.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eSensors\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eSensor replacement is quick and easy with screw type connectors and color coded sensors. The HI 98290 automatically recognizes sensor presence.\u003c\/p\u003e\n\u003cp\u003eThe HI 7609829-2 galvanic DO sensor with its fast response time can be ready at a moment’s notice. This probe features a replaceable membrane cap for easy maintenance.\u003c\/p\u003e\n\u003cp\u003eThe HI 7609829-3 4-electrode conductivity probe uses a polarographic measurement principle and ensures stable conductivity readings that are immune to polarization or surface coating. Absolute conductivity. temperature compensated conductivity. salinity. specific gravity and TDS determinations are possible with measurements from this sensor.\u003c\/p\u003e\n\u003cp\u003eThe new HI 7609829-4 EC\/turbidity sensor is field replaceable and offers readings from both parameters at the same time.\u003c\/p\u003e\n\u003cp\u003eAll potentiometric sensors feature a double junction design and are gel filled to increase resistance to contamination. An ISE sensor can be used in place of the pH sensor and is automatically recognized. pH in mV readings are also displayed —ideal for troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eA Great Combination\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe use of HANNA’s microprocessor based multiparameter intelligent probes with HI 98290 meter will provide reliable data collection that can lead to an improved scientific understanding of the interconnections between natural. chemical and geological processes and man made pollution to effectively evaluate applications for waste-discharge permits. remediate contaminated sites and to protect or restore biological resources.\u003c\/p\u003e\n\u003cp\u003eThe HI 76x9829 probes utilize field replaceable sensors with auto-recognition. The sensors are housed with the probe electronics in a rugged housing with a water-tight cable connection. The base probe model permits the measurement of conductivity. pH\/ORP (or an ISE). and dissolved oxygen. Other models permit turbidity and logging.\u003c\/p\u003e\n\u003cp\u003eThe probes are available with a choice of cable lengths such as 4 m and 10 m and 20 m (13. 33’) that utilize a DIN connection to interface with the meters. The probes are supplied with a maintenance kit in the carrying case versions. These new probes can be connected directly to a PC with the HI 96982910 USB adapter. and the HI 929829 PC software to communicate directly with the probes.\u003c\/p\u003e\n\u003cp\u003eReliable temperature measurements are a critical parameter of aquatic system monitoring. Temperature and temperature changes due to water releases can affect the ability of water to hold oxygen as well as the ability of organisms to resist certain pollutants. The intelligent probes incorporate an accurate thermistor that changes predictably with temperature changes. Accurate temperature reading in degrees Celsius. Kelvin or Fahrenheit are displayed and utilized by other detectors for temperature correction.\u003c\/p\u003e\n\u003cp\u003eThe pH or pH\/ORP sensors incorporate the technology that has made HANNA so successful as a pH manufacturer. Reliable pH measurements are one of the most important indicators of water chemistry indicating the relative amount of free hydrogen and hydroxyl ions in the water. HANNA’s pH sensors utilize a resilient PEI body to protect them from solid particulates found water samples. Consistency and quality are the hallmarks of these sensors. Our differential measurement system further enhances the measurement reliability providing temperature corrected pH.\u003c\/p\u003e\n\u003cp\u003eA choice of 3 ion selective electrodes is available for constant reporting of common surface water contaminants. Nitrate. ammonium and chloride are available. Each ISE is a combination electrode incorporating an extremely constant reference spiral; all potentionmetric probes feature a double junction and solid gelled reference design. By utilizing conductivity. the HI 98290 can convert ion activity measurements to concentration units. \u003c\/p\u003e\n\u003cp\u003eThe HANNA 4-electrode conductivity probe using the polarographic measurement principal ensures stable conductivity readings. Electrolytic conductivity measures of the ability of water to conduct an electrical current. It is highly dependent on the amount of dissolved solids (such as salt) in the water. Absolute conductivity. temperature corrected conductivity. salinity. specific gravity and water hardness (TDS) determinations are possible with measurements from this sensor.\u003c\/p\u003e\n\u003cp\u003eThe oxygen dissolved in lakes. rivers. and oceans is crucial for the organisms and creatures living in it. If dissolved oxygen concentrations drop below normal levels in water bodies. the water quality degrades and the organisms begin to die off. The galvanic sensor does not require long polarization times so is ready for measurement at a moment’s notice. Our sensor also utilizes a replaceable cap design for ease of maintenance and a safe non-toxic electrolyte. DO readings are compensated for the effects of temperature (using the probes built-in temperature sensor) and atmospheric pressure (using the HI 98290’s internal atmospheric pressure sensor).\u003c\/p\u003e\n\u003cp\u003eThe new HANNA turbidity sensor is a replaceable design for instantaneous turbidity reading that conforms to ISO 7027 standards. It provides measurements from 0.0 to 50.0 FNU; and 50 to 1000 FNU. Turbidity is the amount of particulate matter that is suspended in water. Turbidity measures the scattering effect that suspended solids have on light: the higher the intensity of scattered light. the higher the turbidity. Material that causes water to be turbid include: clay. silt. finely divided organic and inorganic matter. soluble colored organic compounds. plankton and microscopic organisms.\u003c\/p\u003e\n\u003cp\u003eProbes with the logging function have a logging memory that allows storage of up to 140.000 individual samples or 12.000 complete sample data sets with date and time stamp thus permitting up to a 35 day deployment with all channels logging at 10 minute intervals. Logging probes work with either rechargeable or standard batteries\u003c\/p\u003e\n\u003cp\u003eThe probe incorporates a temperature sensor for temperature compensation of all parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eMonitoring and Tracking\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eWhen data collection or monitoring requires tracking capabilities. two kinds of methods can be included with the data—timestamp and location. The timestamp expresses the date and the time when the measurement was taken. The time and date (timestamp) are determined by the internal real time clock of the HI 98290. As for location of measurement. the HI 98290 offers two solutions. One is GPS tracking using the HI 98290’s internal 12 channel GPS receiver. The second is the FastTracker™ Tag ID system using ID encoded TAGs mounted at the location sites. Users simply touch the TAG receiver to the mounted TAG to store data along with location ID.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eGPS (Global Positioning System) Enabled\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe new HI 98290 features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data. The GPS tracks your location using satellites to within 30 ft (10 m) so you can be sure that you return to the same location for repeated measurements.\u003c\/p\u003e\n\u003cp\u003eUsers can connect to GPS tracking software such as Google™ Maps* to view locations where samples have been taken. Measurement information is shown right on the map.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eFast Tracker™—Tag Identification System\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eHANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButton®s with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button. measurements are logged and labeled with the alphanumeric user-entered location ID. Location. date. time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eiButton\u003csup\u003e®\u003c\/sup\u003e Tags are Easy to Install\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eInstall the optional TAGs near your sampling points for quick and easy iButton® readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003e*Google™ is a registered trademark of Google™. inc. HANNA Instruments® has no affiliation with Google™.\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003eChoose your configuration -\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMETER ONLY. CARTON BOX PACKAGING\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHI 98290-01\u003c\/strong\u003e Meter only with GPS enabled. charging adapter and instruction manual. 115VAC \u003cbr\u003e\u003cstrong\u003eHI 98290-02\u003c\/strong\u003e Meter only with GPS enabled. charging adapter and instruction manual. 230VAC \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETER AND PROBE ONLY. NO SENSORS. CARRYING CASE PACKAGING\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHI 98295-01\u003c\/strong\u003e HI 98290 with GPS and HI 7629829\/4 logging probe for pH\/pH+ORP\/ISE. DO. EC. temperature. with 4 m (13.1’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 115VAC\u003cbr\u003e\u003cstrong\u003eHI 98295-02\u003c\/strong\u003e HI 98290 with GPS and HI 7629829\/4 logging probe for pH\/pH+ORP\/ISE. DO. EC. temperature. with 4 m (13.1’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 230VAC\u003cbr\u003e\u003cstrong\u003eHI 98296-01\u003c\/strong\u003e HI 98290 with GPS and HI 7639829\/4 logging probe for pH\/pH+ORP\/ISE. DO. EC+turbidity. temperature. with 4 m (13.1’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 115VAC\u003cbr\u003e\u003cstrong\u003eHI 98296-02\u003c\/strong\u003e HI 98290 with GPS and HI 7639829\/4 logging probe for pH\/pH+ORP\/ISE. DO. EC+turbidity. temperature. with 4 m (13.1’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 230VAC\u003cbr\u003e\u003cstrong\u003eHI 98297-01\u003c\/strong\u003e HI 98290 with GPS and HI 7629829\/10 logging probe for pH\/pH+ORP\/ISE. DO. EC. temperature. with 10 m (33’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 115VAC\u003cbr\u003e\u003cstrong\u003eHI 98297-02\u003c\/strong\u003e HI 98290 with GPS and HI 7629829\/10 logging probe for pH\/pH+ORP\/ISE. DO. EC. temperature. with 10 m (33’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 230VAC\u003cbr\u003e\u003cstrong\u003eHI 98298-01\u003c\/strong\u003e HI 98290 with GPS and HI 7639829\/10 logging probe for pH\/pH+ORP\/ISE. DO. EC+turbidity. temperature. with 10 m (33’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 115VAC\u003cbr\u003e\u003cstrong\u003eHI 98298-02\u003c\/strong\u003e HI 98290 with GPS and HI 7639829\/10 logging probe for pH\/pH+ORP\/ISE. DO. EC+turbidity. temperature. with 10 m (33’) cable. probe maintenance kit. charging adapter. instruction manual and hard carrying case. 230VAC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eSensors for all meter and probe configurations are sold separately. see configurations up above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003epH\/mV of pH input\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 14.00 pH \/ ±600.0 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eORP mV\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2000.0 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAmmonium-\u003cbr\u003eNitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.02 to 200 ppm (as N)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eChloride\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.6 to 200 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNitrate-Nitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.62 to 200 ppm (as N)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eConductivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 200 mS\/cm (absolute EC up to 400 mS\/cm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 400000 mg\/L or ppm (the maximum value depends on the TDS factor)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eResistivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 70.00 PSU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSeawater σ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50.0 σ\u003csub\u003et\u003c\/sub\u003e. σ\u003csub\u003e0\u003c\/sub\u003e. σ\u003csub\u003e15\u003c\/sub\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 99.9 FNU; 100 to 1000 FNU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 500.0%; 0.00 to 50.00 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAtm. Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003epH\/mV of pH input\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 pH \/ 0.1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eORP mV\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAmmonium-\u003cbr\u003eNitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eChloride\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNitrate-Nitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eConductivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cem\u003emanual:\u003c\/em\u003e 1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm; \u003cem\u003eautomatic:\u003c\/em\u003e 1 µS\/cm from 0 to 9999 µS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm; \u003cem\u003eautomatic mS\/cm:\u003c\/em\u003e 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cem\u003emanual:\u003c\/em\u003e 1 mg\/L (ppm); 0.001 g\/L (ppt); 0.01g\/L (ppt); 0.1 g\/L (ppt); 1 g\/L (ppt); \u003cem\u003eautorange scales:\u003c\/em\u003e 1 mg\/L (ppm) from 0 to 9999 mg\/L (ppm); 0.01 g\/L (ppt) from 10.00 to 99.99 g\/L (ppt); 0.1 g\/L (ppt) from 100.0 to 400.0 g\/L (ppt); \u003cem\u003eautorange g\/L (ppt) scales:\u003c\/em\u003e 0.001 g\/L (ppt) from 0.000 to 9.999 g\/L (ppt); 0.01 g\/L (ppt) from 10.00 to 99.99 g\/L (ppt); 0.1 g\/L (ppt) from 100.0 to 400.0 g\/L (ppt)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eResistivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edependent on resistivity reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 PSU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSeawater σ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 σ\u003csub\u003et\u003c\/sub\u003e. σ\u003csub\u003e0\u003c\/sub\u003e. σ\u003csub\u003e15\u003c\/sub\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 FNU from 0.0 to 99.9 FNU; 1 FNU from 100 to 1000 FNU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1%; 0.01 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAtm. Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01°C; 0.01°F; 0.01K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003epH\/mV of pH input\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.02 pH \/ ±0.5 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eORP mV\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.0 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAmmonium-\u003cbr\u003eNitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±5% of reading or 2 ppm. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eChloride\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±5% of reading or 2 ppm. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNitrate-Nitrogen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±5% of reading or 2 ppm. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eConductivity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading or ±1 µS\/cm. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading or ±1 mg\/L. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2% of reading or ±0.01 PSU. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSeawater σ\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1 σ\u003csub\u003et\u003c\/sub\u003e. σ\u003csub\u003e0\u003c\/sub\u003e. σ\u003csub\u003e15\u003c\/sub\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.3 FNU or ±2% of reading. whichever is greater\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm: ±1.5% of reading or 0.10 ppm. whichever is greater; 30.00 ppm to 50.00 ppm: ±3% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eAtm. Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±3 mm Hg within ±15°C from the temperature during calibration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.15°C; ±0.27°F; ±0.15K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from -5 to 55°C (23 to 131°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGPS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e12 channel receiver\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Memory\u003cbr\u003efrom Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e44.000 records\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 second to 3 hours\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComputer Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eUSB (with HI 929829 software)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastTracker™ TAG ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyes\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaterproof Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eIP67\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V alkaline C cells (4) \/ 1.2V NiMH rechargeable C cells (4). USB. 12V power adapter\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e750g (26.5 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eACCESSORIES\u003c\/h2\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-16\"\u003eHI 9829-16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTurbidity Calibration Solution. 0 FNU. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-17\"\u003eHI 9829-17\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTurbidity Calibration Solution. 20 FNU. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-18\"\u003eHI 9829-18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTurbidity Calibration Solution. 200 FNU. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20929829\"\u003eHI 929829\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePC Application Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698291\"\u003eHI 7698291\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Cable. PC to Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%2076982910\"\u003eHI 76982910\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB cable. PC to Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20710046\"\u003eHI 710046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLighter Cigarette Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698290\"\u003eHI 7698290\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShort Calibration Beaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698293\"\u003eHI 7698293\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLong Calibration Beaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698294\"\u003eHI 7698294\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShort Flow Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698297\"\u003eHI 7698297\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLong. Quick Release Flow Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698295\"\u003eHI 7698295\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShort Protective Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207698296\"\u003eHI 7698296\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLong Protective Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20920005\"\u003eHI 920005\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eiButton\u003csup\u003e®\u003c\/sup\u003e Tags\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20710140\"\u003eHI 710140\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eHard Carrying Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%20710045\"\u003eHI 710045\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eReagents \u0026amp; Standards\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-10\/11\"\u003eHI 9829-10\/11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eISE Standards Kit for HI 7609829-10. 10 Sachets ea.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-10\"\u003eHI 9829-10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ppm Standard Sachets for HI 7609829-10 Ammonium ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-11\"\u003eHI 9829-11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ppm Standard Sachet for HI 7609829-10 Ammonium ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-12\/13\"\u003eHI 9829-12\/13\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eISE Standards kit for HI 7609829-11 Chloride ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-12\"\u003eHI 9829-12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ppm Standard Sachets for HI 7609829-11 Chloride ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-13\"\u003eHI 9829-13\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ppm Standard Sachet for HI 7609829-11 Chloride ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-14\/15\"\u003eHI 9829-14\/15\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eISE Standards for 7609829-12 Nitrate ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-14\"\u003eHI 9829-14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ppm Standard Sachets for HI 7609829-12 Nitrate ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209829-15\"\u003eHI 9829-15\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ppm Standard Sachets for HI 7609829-12 Nitrate ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-0\"\u003eHI 7609829-0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-1\"\u003eHI 7609829-1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH\/ORP Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-2\"\u003eHI 7609829-2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-3\"\u003eHI 7609829-3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-4\"\u003eHI 7609829-4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\/Turbidity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-10\"\u003eHI 7609829-10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAmmonium ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-11\"\u003eHI 7609829-11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eChloride ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207609829-12\"\u003eHI 7609829-12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNitrate ISE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eQuick Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209828-27\"\u003eHI 9828-27\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eQuick Calibration Solution. 1 Gallon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%209828-25\"\u003eHI 9828-25\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eQuick Calibration Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003epH Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207010L\"\u003eHI 7010L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207007L\"\u003eHI 7007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207004L\"\u003eHI 7004L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eORP Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207022L\"\u003eHI 7022L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eORP Test Solution at 470 mV @ 25°C\/77°F)\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207021L\"\u003eHI 7021L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eORP Test Solution at (240 mV @ 25°C\/77°F)\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eDissolved Oxygen Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207042S\"\u003eHI 7042S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution for Galvanic Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eConductivity Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207039L\"\u003eHI 7039L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207035L\"\u003eHI 7035L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e111800 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207034L\"\u003eHI 7034L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e80000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207033L\"\u003eHI 7033L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e84 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207031L\"\u003eHI 7031L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207030L\"\u003eHI 7030L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12880 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eCleaning and Maintenance Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027001\u0026amp;ProdCode=HI%207061L\"\u003eHI 7061L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Cleaning Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e \u003c\/h2\u003e"}
HANNA HI 98290-02 GPS Multiparameter Meter
Related Products
Biobase PH-210 Benchtop pH meter
$1,229.00 $1,695.00
Carbolite Heating element 200mm long
$799.00 $850.00
Carbolite Thermocouple for AAF11/3
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00














