{"product_id":"hi98360","title":"HANNA HI 98360  EC\/TDS\/NaCl\/°C Meter with PC Connectivity","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutoranging. manual ranging and range lock\u003c\/li\u003e\n\u003cli\u003eFour ring \u003cspan id=\"ig6oo6_3\" class=\"ig6oo6\"\u003eprobe design\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAutomatic. manual and no \u003cspan id=\"ig6oo6_1\" class=\"ig6oo6\"\u003eTemperature Compensation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAuto endpoint; Automatically freezes stable readings on the LCD display\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli\u003eOn-screen user guides\u003c\/li\u003e\n\u003cli\u003eBacklit display\u003c\/li\u003e\n\u003cli\u003eLogging of up to 500 records\u003c\/li\u003e\n\u003cli\u003e% Battery displayed on startup\u003c\/li\u003e\n\u003cli\u003eUSB port for PC compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 98360 is a handheld conductivity\/TDS\/salinity\/temperature meter. Users are provided with a series of diagnostic features and messages on the LCD which guide the user through calibration. operation and troubleshooting.\u003c\/p\u003e\n\u003cp\u003eConductivity and TDS measurement parameters are selectable such as: cell constant range from 0.500 to 1.700. temperature coefficient from 0.00 to 6.00%\/ºC. temperature reference from 20 to 25ºC and a selectable TDS factor of 0.40 to 0.80.\u003c\/p\u003e\n\u003cp\u003eThis instrument utilizes the four ring HI 76309\/1.5 \u003cspan id=\"ig6oo6_2\" class=\"ig6oo6\"\u003econductivity probe\u003c\/span\u003e with internal temperature sensor. The four ring design offers accurate readings over all the conductivity range with immunity to polarization and falling that occurs on long term use of amperometric probes.\u003c\/p\u003e\n\u003cp\u003eThe autoranging feature of the EC and TDS modes automatically sets the meter to the scale with the highest possible resolution. The auto endpoint feature automatically freezes the display once a stable reading is reached.\u003c\/p\u003e\n\u003cp\u003eThe HI 98360 includes data logging (up to 500 records) and a USB port for data transfer to a computer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 98360 is supplied with HI 76309\/1.5 conductivity probe. batteries. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 29.99 µS\/cm; 30.0 to 299.9 µS\/cm; 300 to 2999 µS\/cm; 3.00 to 29.99 mS\/cm; 30.0 to 200.0 mS\/cm; up to 500.0 mS\/cm (actual EC)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 14.99 mg\/L (ppm); 15.0 to 149.9 mg\/L (ppm); 150 to 1499 mg\/L (ppm); 1.50 to 14.99 g\/L (ppt); 15.0 to 100.0 g\/L (ppt); up to 400.0 g\/L (ppt) (actual TDS) with 0.80 conversion factor\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNaCl\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 400.0%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e–20.0 to 120.0 ºC (-4.0 to 248.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 µS\/cm; 0.1 µS\/cm; 1 µS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 mg\/L (ppm); 0.1 mg\/L (ppm); 1 mg\/L (ppm); 0.01 g\/L (ppt); 0.1 g\/L (ppt)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNaCl\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.5% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.5% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNaCl\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.5% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. one point with six memorized values (84. 1413. 5000. 12880. 80000. 111800 µS\/cm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eNaCl\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone point with HI 7037 calibration solution\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003etwo point. at 0 and 50°C (32 and 122°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic or manual from –20.0 to 120.0 ºC (-4.0 to 248.0ºF) (can be disabled for measuring conductivity)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCoefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eselectable from 0.00 to 6.00%\/ºC (EC and TDS only); default value is 1.90%\/ºC\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Conversion Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eselectable from 0.40 to 0.80 (default value is 0.50)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003elog on demand. up to 500 samples\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 76309\/1.5 four ring conductivity probe with internal temperature sensor. DIN connector and 1.5 m (4.9’) cable\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA batteries (3) \/approximately 200 hours of continuous use without backlight (50 hours with backlight on); auto-off after 5. 10. 20 and 60 minutes (can be disabled)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e300 g (10.6 oz)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%207030L\"\u003eHI 7030L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12880 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%207031L\"\u003eHI 7031L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%207033L\"\u003eHI 7033L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e84 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%207034L\"\u003eHI 7034L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e80000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%207035L\"\u003eHI 7035L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e111800 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%207039L\"\u003eHI 7039L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%207037L\"\u003eHI 7037L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibration Solution for % Readings (100% NaCl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%207061L\"\u003eHI 7061L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Cleaning Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%20920011\"\u003eHI 920011\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 Cable for PC Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%2076309\/1.5\"\u003eHI 76309\/1.5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Ring Potentiometric Probe\u003cbr\u003e\u003csmall\u003ewith 1.5 m (4.9') cable\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044007\u0026amp;ProdCode=HI%2076309\"\u003eHI 76309\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Ring Potentiometric Probe\u003cbr\u003e\u003csmall\u003ewith 1 m (3.3') cable\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857143557,"sku":"HI98360","price":1243.62,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/ectds-handmessgerat-mit-nacl-bereich-auto-endpunkt-pc-interface-1499_1-1_2015.jpeg?v=1443494805","url":"https:\/\/acornsci.co.nz\/products\/hi98360","provider":"Acorn Scientific","version":"1.0","type":"link"}