{"id":1582163973,"title":"HANNA HI 98402 Fluoride\/°C (ISE)Meter","handle":"hi98402","description":"\u003cp\u003eHI 98402 measures fluoride from 0.05 mg\/L to 1.9 g\/L in 5 distinct scales. With autoranging. HI 98402 automatically selects the range that provides the best resolution.\u003c\/p\u003e\n\u003cp\u003eHI 98402 automatically compensates for temperature from -5 to 55°C using the optional HI 7662 stainless steel temperature probe. Both the temperature measured together with fluoride concentrations are displayed on the large LCD.\u003c\/p\u003e\n\u003cp\u003eCalibration is automatic at 1 or two points. The calibration points can be chosen among 1 mg\/L. 2 mg\/L. 10 mg\/L. 100 mg\/L and 1000 mg\/L.\u003c\/p\u003e\n\u003cp\u003eHI 98402 is supplied in a rugged carrying case complete with batteries that provide up to 200 hours of continuous operation.\u003c\/p\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTutorial messages on LCD display\u003c\/li\u003e\n\u003cli\u003eDirect measurements in mg\/L or g\/L\u003c\/li\u003e\n\u003cli\u003eWaterproof. rugged housing for indoor\/outdoor applications\u003c\/li\u003e\n\u003cli\u003eExtensive fluoride scale\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 98402 is supplied with batteries. rugged carrying case and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_98402.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFluoride\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.050 to 0.500 mg\/L 0.50 to 5.00 mg\/L 5.0 to 50.0 mg\/L 50 to 500 mg\/L 0.50 to 1.90 g\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120.0ºC (-4.0 to 248.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluoride\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.001 mg\/L (ppm) 0.01 mg\/L 0.1 mg\/L 1 mg\/L 0.01 g\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (0.1ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. one or two point at 1 mg\/L. 2 mg\/L. 10 mg\/L. 100 mg\/L and 1000 mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. -5 to 55°C (with temperature probe)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 4010 fluoride electrode with BNC connector and 1 m (3.3') cable (not included) HI 5313 reference electrode with 1 m (3.3') cable (not included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 7662 stainless steel temperature probe with 1 m (3.3') cable (not included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA (3) \/ approximately 200 hours of continuous use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e300 g (10.6 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T16:18:37+12:00","created_at":"2015-09-01T15:15:29+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters"],"price":73500,"price_min":73500,"price_max":73500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857292293,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI98402","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 98402 Fluoride\/°C (ISE)Meter","public_title":null,"options":["Default Title"],"price":73500,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/instrument-pour-la-mesure-de-fluorures-1500_1-1_2015.jpeg?v=1443495617"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/instrument-pour-la-mesure-de-fluorures-1500_1-1_2015.jpeg?v=1443495617","options":["Title"],"media":[{"alt":"HANNA HI 98402 Fluoride\/°C (ISE)Meter - Acorn Scientific","id":21298774115,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/instrument-pour-la-mesure-de-fluorures-1500_1-1_2015.jpeg?v=1443495617"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/instrument-pour-la-mesure-de-fluorures-1500_1-1_2015.jpeg?v=1443495617","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eHI 98402 measures fluoride from 0.05 mg\/L to 1.9 g\/L in 5 distinct scales. With autoranging. HI 98402 automatically selects the range that provides the best resolution.\u003c\/p\u003e\n\u003cp\u003eHI 98402 automatically compensates for temperature from -5 to 55°C using the optional HI 7662 stainless steel temperature probe. Both the temperature measured together with fluoride concentrations are displayed on the large LCD.\u003c\/p\u003e\n\u003cp\u003eCalibration is automatic at 1 or two points. The calibration points can be chosen among 1 mg\/L. 2 mg\/L. 10 mg\/L. 100 mg\/L and 1000 mg\/L.\u003c\/p\u003e\n\u003cp\u003eHI 98402 is supplied in a rugged carrying case complete with batteries that provide up to 200 hours of continuous operation.\u003c\/p\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTutorial messages on LCD display\u003c\/li\u003e\n\u003cli\u003eDirect measurements in mg\/L or g\/L\u003c\/li\u003e\n\u003cli\u003eWaterproof. rugged housing for indoor\/outdoor applications\u003c\/li\u003e\n\u003cli\u003eExtensive fluoride scale\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 98402 is supplied with batteries. rugged carrying case and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_98402.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFluoride\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.050 to 0.500 mg\/L 0.50 to 5.00 mg\/L 5.0 to 50.0 mg\/L 50 to 500 mg\/L 0.50 to 1.90 g\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120.0ºC (-4.0 to 248.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluoride\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.001 mg\/L (ppm) 0.01 mg\/L 0.1 mg\/L 1 mg\/L 0.01 g\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (0.1ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. one or two point at 1 mg\/L. 2 mg\/L. 10 mg\/L. 100 mg\/L and 1000 mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. -5 to 55°C (with temperature probe)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 4010 fluoride electrode with BNC connector and 1 m (3.3') cable (not included) HI 5313 reference electrode with 1 m (3.3') cable (not included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 7662 stainless steel temperature probe with 1 m (3.3') cable (not included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA (3) \/ approximately 200 hours of continuous use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e300 g (10.6 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}

HANNA HI 98402 Fluoride/°C (ISE)Meter

Product Description

HI 98402 measures fluoride from 0.05 mg/L to 1.9 g/L in 5 distinct scales. With autoranging. HI 98402 automatically selects the range that provides the best resolution.

HI 98402 automatically compensates for temperature from -5 to 55°C using the optional HI 7662 stainless steel temperature probe. Both the temperature measured together with fluoride concentrations are displayed on the large LCD.

Calibration is automatic at 1 or two points. The calibration points can be chosen among 1 mg/L. 2 mg/L. 10 mg/L. 100 mg/L and 1000 mg/L.

HI 98402 is supplied in a rugged carrying case complete with batteries that provide up to 200 hours of continuous operation.

  

  • Tutorial messages on LCD display
  • Direct measurements in mg/L or g/L
  • Waterproof. rugged housing for indoor/outdoor applications
  • Extensive fluoride scale
  • Automatic Temperature Compensation

Order Information:   HI 98402 is supplied with batteries. rugged carrying case and instructions.

Product Manuals

  Manual: Download

Specification :

  Fluoride 0.050 to 0.500 mg/L 0.50 to 5.00 mg/L 5.0 to 50.0 mg/L 50 to 500 mg/L 0.50 to 1.90 g/L
  Temperature -20.0 to 120.0ºC (-4.0 to 248.0ºF)
Resolution Fluoride 0.001 mg/L (ppm) 0.01 mg/L 0.1 mg/L 1 mg/L 0.01 g/L
  Temperature 0.1°C (0.1ºF)
Calibration   automatic. one or two point at 1 mg/L. 2 mg/L. 10 mg/L. 100 mg/L and 1000 mg/L
Temperature Compensation   automatic. -5 to 55°C (with temperature probe)
Electrode   HI 4010 fluoride electrode with BNC connector and 1 m (3.3') cable (not included) HI 5313 reference electrode with 1 m (3.3') cable (not included)
Temperature Probe   HI 7662 stainless steel temperature probe with 1 m (3.3') cable (not included)
Input Impedance   1012 Ohm
Battery Type / Life   1.5V AAA (3) / approximately 200 hours of continuous use
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)
Weight   300 g (10.6 oz.)

 