{"id":1582157637,"title":"HANNA HI 991300 Multiparameter pH\/EC\/TDS\/°C - EC to 3999 µS","handle":"hi991300","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 991300\u003c\/strong\u003e has been designed to offer you pH. conductivity. total dissolved solids and temperature measurements all in a slim. lightweight. portable unit. From purified to brine water measurement. you can select the meter which will work best with your range of conductivity for greater precision.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThere are only 2 buttons. yet you can select from a range of calibration buffers and even the temperature scale (°C or °F) most familiar to you. The housing is waterproof and rated for IP 67 conditions.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 1288 pre-amplified multiparameter probe features an easy to clean sensor and a cloth junction that can be pulled longer to increase the life of the probe. To ensure against interference from transient electrical noise. a solid-state amplifier is integrated into the HI 1288.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eUser selectable features include different TDS factors from 0.45 to 1.00 and a range of temperature coefficients (β) from 0.0 to 2.4% for greater consistency and reproducibility. Standardized buffer recognition values are also selectable.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThis instrument easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesn’t get in your way. The large. multi-level LCD displays the primary reading. temperature and calibration guides simultaneously.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic one or two point calibration\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMulti-level LCD display; The meters display the current measurement simultaneously with the current temperature.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eOn-screen tutorial messages for calibration and setup\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eHOLD; The HOLD button freezes readings on the display for manual recording\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMeasure pH. EC\/TDS and temperature with one probe\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBattery % displayed on startup\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eEasy to clean and keep clean\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 991300 is supplied with HI 1288 multiparameter probe. HI 70004 pH 4.01 buffet solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 70031 1413 µS\/cm calibration solution sachet. HI 70032 1382 mg\/L (ppm) calibration solution sachet. HI 700661 electrode cleaning solution sachet. batteries. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_991300_01.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C (32.0 to 140.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (±1.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eselectable 0.45 to 1.00 with 0.01 increments (default 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. one or two point calibration with two sets of memorized buffers (Standard 4.01. 7.01. 10.01 or NIST 4.01. 6.86. 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 point at 1382 ppm (CONV 0.5) at 1500 ppm (CONV 0.7) at 1413 µS\/cm (others)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEC\/TDS\u003c\/td\u003e\n\u003ctd\u003eAutomatic with selectable ß from 0.0 to 2.4%\/°C with 0.1 increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1288 PVC body. pre-amplified multiparameter probe with internal temperature sensor. DIN connector and 1.2 m (3.93’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V AAA (3) \/approximately 500 hours of continuous use. auto-off after 8 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e205 g (7.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eClick on the links below to download the Safety Data Sheet.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hannainst.com\/sds\/SDS_HI%2070004_2013-06-13.pdf\"\u003eHI 70004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hannainst.com\/sds\/SDS_HI%2070007_2013-06-13.pdf\"\u003eHI 70007\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hannainst.com\/sds\/SDS_HI%2070031_2013-06-13.pdf\"\u003eHI 70031\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hannainst.com\/sds\/SDS_HI%2070032_2013-06-13.pdf\"\u003eHI 70032\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2026-06-25T16:18:59+12:00","created_at":"2015-09-01T15:14:38+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters","Type_pH \u0026 ORP Meters"],"price":83695,"price_min":83695,"price_max":83695,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857282949,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI991300","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 991300 Multiparameter pH\/EC\/TDS\/°C - EC to 3999 µS","public_title":null,"options":["Default Title"],"price":83695,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/phectdsc-handmessgerat-bis-3999-s-1510_1-1_2015.jpeg?v=1443495519"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/phectdsc-handmessgerat-bis-3999-s-1510_1-1_2015.jpeg?v=1443495519","options":["Title"],"media":[{"alt":"HANNA HI 991300 Multiparameter pH\/EC\/TDS\/°C - EC to 3999 µS - Acorn Scientific","id":21296316515,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/phectdsc-handmessgerat-bis-3999-s-1510_1-1_2015.jpeg?v=1443495519"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/phectdsc-handmessgerat-bis-3999-s-1510_1-1_2015.jpeg?v=1443495519","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 991300\u003c\/strong\u003e has been designed to offer you pH. conductivity. total dissolved solids and temperature measurements all in a slim. lightweight. portable unit. From purified to brine water measurement. you can select the meter which will work best with your range of conductivity for greater precision.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThere are only 2 buttons. yet you can select from a range of calibration buffers and even the temperature scale (°C or °F) most familiar to you. The housing is waterproof and rated for IP 67 conditions.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 1288 pre-amplified multiparameter probe features an easy to clean sensor and a cloth junction that can be pulled longer to increase the life of the probe. To ensure against interference from transient electrical noise. a solid-state amplifier is integrated into the HI 1288.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eUser selectable features include different TDS factors from 0.45 to 1.00 and a range of temperature coefficients (β) from 0.0 to 2.4% for greater consistency and reproducibility. Standardized buffer recognition values are also selectable.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThis instrument easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesn’t get in your way. The large. multi-level LCD displays the primary reading. temperature and calibration guides simultaneously.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic one or two point calibration\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMulti-level LCD display; The meters display the current measurement simultaneously with the current temperature.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eOn-screen tutorial messages for calibration and setup\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eHOLD; The HOLD button freezes readings on the display for manual recording\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMeasure pH. EC\/TDS and temperature with one probe\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBattery % displayed on startup\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eEasy to clean and keep clean\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 991300 is supplied with HI 1288 multiparameter probe. HI 70004 pH 4.01 buffet solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 70031 1413 µS\/cm calibration solution sachet. HI 70032 1382 mg\/L (ppm) calibration solution sachet. HI 700661 electrode cleaning solution sachet. batteries. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_991300_01.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C (32.0 to 140.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (±1.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eselectable 0.45 to 1.00 with 0.01 increments (default 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. one or two point calibration with two sets of memorized buffers (Standard 4.01. 7.01. 10.01 or NIST 4.01. 6.86. 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 point at 1382 ppm (CONV 0.5) at 1500 ppm (CONV 0.7) at 1413 µS\/cm (others)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEC\/TDS\u003c\/td\u003e\n\u003ctd\u003eAutomatic with selectable ß from 0.0 to 2.4%\/°C with 0.1 increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1288 PVC body. pre-amplified multiparameter probe with internal temperature sensor. DIN connector and 1.2 m (3.93’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V AAA (3) \/approximately 500 hours of continuous use. auto-off after 8 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e205 g (7.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eClick on the links below to download the Safety Data Sheet.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hannainst.com\/sds\/SDS_HI%2070004_2013-06-13.pdf\"\u003eHI 70004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hannainst.com\/sds\/SDS_HI%2070007_2013-06-13.pdf\"\u003eHI 70007\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hannainst.com\/sds\/SDS_HI%2070031_2013-06-13.pdf\"\u003eHI 70031\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hannainst.com\/sds\/SDS_HI%2070032_2013-06-13.pdf\"\u003eHI 70032\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e"}
HANNA HI 991300 Multiparameter pH/EC/TDS/°C - EC to 3999 µS
Related Products
Biobase PH-210 Benchtop pH meter
$1,229.00 $1,695.00
Carbolite Heating element 200mm long
$799.00 $850.00
Carbolite Thermocouple for AAF11/3
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00














