Email info@acornsci.com for orders and inquiries.

{"id":1582095237,"title":"HANNA HI 99181 pH Meter for Skin","handle":"hi99181","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003ePre-amplified flat-tip pH electrode with built-in temperature sensor allows for maximum surface contact\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMulti-level LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eOn-screen tutorial messages for calibration and set-up\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic one or two point calibration\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBattery % displayed on startup\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eCompact. heavy-duty. and waterproof\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eEasy to clean and keep clean\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 99181\u003c\/strong\u003e is a pH meter specifically designed for skin analysis. Essential for labs researching the biological compatibility of cosmetics and pharmaceuticals. HI 99181 provides quick and simple measurements without compromising precision.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe amplified HI 1414D\/50 probe has been specially designed with a flat tip for accurate skin pH measurement with maximum surface contact.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 99181 is supplied with HI 1414D\/50 flat tipped pH\/temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700620 electrode cleaning and disinfection solution for skin residuals sachets (2). HI 700621 electrode cleaning solution for skin grease and sebum sachets (2). batteries. instructions and hard carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist99181z_11_01_11.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0°C \/ 23.0 to 221.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (up to 60°C). ±1.0°C (outside) \/ ±1.0°F (up to 140°F); ±2.0°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 or 2 point with 2 sets of memorized buffer values (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. -5 to 105°C (23 to 221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1414D\/50. amplified. flat tip. with internal temperature sensor. 50mm (2.0\") long body (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V AAA (3) \/ approximately 1200 hours of continuous use. auto-off after eight minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e205g (7.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T16:29:16+12:00","created_at":"2015-09-01T15:06:35+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":87400,"price_min":87400,"price_max":87400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857144645,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI99181","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 99181 pH Meter for Skin","public_title":null,"options":["Default Title"],"price":87400,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hand-ph-meter-fur-haut-1522_1-1_2015.jpeg?v=1443494813"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hand-ph-meter-fur-haut-1522_1-1_2015.jpeg?v=1443494813","options":["Title"],"media":[{"alt":null,"id":21275607139,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hand-ph-meter-fur-haut-1522_1-1_2015.jpeg?v=1443494813"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hand-ph-meter-fur-haut-1522_1-1_2015.jpeg?v=1443494813","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003ePre-amplified flat-tip pH electrode with built-in temperature sensor allows for maximum surface contact\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMulti-level LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eOn-screen tutorial messages for calibration and set-up\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic one or two point calibration\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBattery % displayed on startup\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eCompact. heavy-duty. and waterproof\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eEasy to clean and keep clean\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 99181\u003c\/strong\u003e is a pH meter specifically designed for skin analysis. Essential for labs researching the biological compatibility of cosmetics and pharmaceuticals. HI 99181 provides quick and simple measurements without compromising precision.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe amplified HI 1414D\/50 probe has been specially designed with a flat tip for accurate skin pH measurement with maximum surface contact.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 99181 is supplied with HI 1414D\/50 flat tipped pH\/temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700620 electrode cleaning and disinfection solution for skin residuals sachets (2). HI 700621 electrode cleaning solution for skin grease and sebum sachets (2). batteries. instructions and hard carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist99181z_11_01_11.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0°C \/ 23.0 to 221.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (up to 60°C). ±1.0°C (outside) \/ ±1.0°F (up to 140°F); ±2.0°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 or 2 point with 2 sets of memorized buffer values (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. -5 to 105°C (23 to 221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1414D\/50. amplified. flat tip. with internal temperature sensor. 50mm (2.0\") long body (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V AAA (3) \/ approximately 1200 hours of continuous use. auto-off after eight minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e205g (7.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

HANNA HI 99181 pH Meter for Skin

Product Description
  • Pre-amplified flat-tip pH electrode with built-in temperature sensor allows for maximum surface contact
  • Multi-level LCD display
  • On-screen tutorial messages for calibration and set-up
  • Automatic Temperature Compensation
  • Automatic one or two point calibration
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings
  • Battery % displayed on startup
  • Compact. heavy-duty. and waterproof
  • Easy to clean and keep clean

 

HI 99181 is a pH meter specifically designed for skin analysis. Essential for labs researching the biological compatibility of cosmetics and pharmaceuticals. HI 99181 provides quick and simple measurements without compromising precision.

The amplified HI 1414D/50 probe has been specially designed with a flat tip for accurate skin pH measurement with maximum surface contact.

 

 

Order Information:   HI 99181 is supplied with HI 1414D/50 flat tipped pH/temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700620 electrode cleaning and disinfection solution for skin residuals sachets (2). HI 700621 electrode cleaning solution for skin grease and sebum sachets (2). batteries. instructions and hard carrying case.

Product Manuals

  Manual: Download

Specification :

Range pH -2.00 to 16.00 pH
  Temperature -5.0 to 105.0°C / 23.0 to 221.0°F
Resolution pH 0.01 pH
  Temperature 0.1°C / 0.1°F
Accuracy @ 20°C pH ±0.02 pH
  Temperature ±0.5°C (up to 60°C). ±1.0°C (outside) / ±1.0°F (up to 140°F); ±2.0°F (outside)
pH Calibration   automatic. 1 or 2 point with 2 sets of memorized buffer values (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
Temperature Compensation   Automatic. -5 to 105°C (23 to 221°F)
pH Electrode   HI 1414D/50. amplified. flat tip. with internal temperature sensor. 50mm (2.0") long body (included)
Battery Type / Life   1.5V AAA (3) / approximately 1200 hours of continuous use. auto-off after eight minutes of non-use
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)
Weight   205g (7.2 oz.)

 

This product is available upon request. Contact us for more information.