{"id":74148315152,"title":"Stuart Sample Concentrator, SBHCONC\/1","handle":"stuart-sample-concentrator-sbhconc-1","description":"\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eFast efficient sample concentration \u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eSuitable for all tube configurations \u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eCompatible with Stuart three block heaters only\u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eA sample concentrator is a fast and convenient way of concentrating multiple samples in a block heater at once. Utilising a simple gas delivery system the sample concentrator passes gas over the surface of your samples via stainless steel needles. This in combination with the heat from the block heater below produces ideal conditions for fast, efficient evaporation.\u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eThe gas delivery needles are inserted into a silicon membrane, in virtually any configuration. The height of the sample concentrators gas reservoir is located on an adjustable stand for accurate height control. This combines to make the sample concentrator compatible with any combination of block heater sample vessels. \u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eThe gas delivery needles are available in either 76mm or 127mm lengths to suit various tube heights, optional PTFE coating is available for corrosive solutions.\u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eThe Stuart sample concentrator is only compatible with the SBH130D\/3 and SBH200D\/3.\u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eNote: Needles must be purchased separately\u003c\/span\u003e","published_at":"2018-01-12T15:17:11+13:00","created_at":"2018-01-12T15:20:26+13:00","vendor":"Stuart","type":"Other Lab Equipment","tags":["brand_Stuart","Category_Heating"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":539308261392,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Stuart Sample Concentrator, SBHCONC\/1","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/SBH200D_842bd017-81be-43e5-856a-6aab4f31992a.jpg?v=1515723627"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/SBH200D_842bd017-81be-43e5-856a-6aab4f31992a.jpg?v=1515723627","options":["Title"],"media":[{"alt":null,"id":511000281187,"position":1,"preview_image":{"aspect_ratio":0.654,"height":358,"width":234,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/SBH200D_842bd017-81be-43e5-856a-6aab4f31992a.jpg?v=1568996032"},"aspect_ratio":0.654,"height":358,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/SBH200D_842bd017-81be-43e5-856a-6aab4f31992a.jpg?v=1568996032","width":234}],"content":"\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eFast efficient sample concentration \u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eSuitable for all tube configurations \u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eCompatible with Stuart three block heaters only\u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eA sample concentrator is a fast and convenient way of concentrating multiple samples in a block heater at once. Utilising a simple gas delivery system the sample concentrator passes gas over the surface of your samples via stainless steel needles. This in combination with the heat from the block heater below produces ideal conditions for fast, efficient evaporation.\u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eThe gas delivery needles are inserted into a silicon membrane, in virtually any configuration. The height of the sample concentrators gas reservoir is located on an adjustable stand for accurate height control. This combines to make the sample concentrator compatible with any combination of block heater sample vessels. \u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eThe gas delivery needles are available in either 76mm or 127mm lengths to suit various tube heights, optional PTFE coating is available for corrosive solutions.\u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eThe Stuart sample concentrator is only compatible with the SBH130D\/3 and SBH200D\/3.\u003c\/span\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cbr style=\"background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,\u0026amp;quot; segoe ui\u0026amp;quot;,optima,arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #555555; font-family: Calibri,Candara,Segoe,'Segoe UI',Optima,Arial,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003eNote: Needles must be purchased separately\u003c\/span\u003e"}

Stuart Sample Concentrator, SBHCONC/1

Product Description
Fast efficient sample concentration
Suitable for all tube configurations
Compatible with Stuart three block heaters only

A sample concentrator is a fast and convenient way of concentrating multiple samples in a block heater at once. Utilising a simple gas delivery system the sample concentrator passes gas over the surface of your samples via stainless steel needles. This in combination with the heat from the block heater below produces ideal conditions for fast, efficient evaporation.

The gas delivery needles are inserted into a silicon membrane, in virtually any configuration. The height of the sample concentrators gas reservoir is located on an adjustable stand for accurate height control. This combines to make the sample concentrator compatible with any combination of block heater sample vessels.

The gas delivery needles are available in either 76mm or 127mm lengths to suit various tube heights, optional PTFE coating is available for corrosive solutions.

The Stuart sample concentrator is only compatible with the SBH130D/3 and SBH200D/3.

Note: Needles must be purchased separately