Email info@acornsci.com for orders and inquiries.

{"id":6779923824739,"title":"AIRCLEAN SYSTEMS Polypropylene - Folding Sash Ductless","handle":"airclean-systems-ac4000s220-ductless-1","description":"\u003cdiv class=\"o_g parameterList\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_g parameterList\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Parameters\u003c\/h2\u003e\n\u003cp\u003ePolypropylene ductless fume hoods protect both the operator and the environment by filtering toxic fumes, vapors, or gases through AirClean® Systems’ proprietary bonded carbon filtration. Standard with a thermally-fused integral spill tray, polypropylene ductless fume hoods are chemically resistant to virtually all corrosive applications.\u003c\/p\u003e\n\u003cp\u003eFor the widest application range possible, each polypropylene hood is designed to accommodate up to seven inches of filtration. By stacking a HEPA filter followed by a bonded carbon filter, the operator can effectively filter both toxic particulate and chemical fumes. For high evaporation or multi-chemical applications, a full seven-inch stack of chemical filtration may be recommended.\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-2 text-white h5 p-2\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirSafe® automatic safety controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral base with deep spill lip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo ductwork required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo installation required - plugs directly into a standard 110V or 220V electrical outlet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolypropylene construction for chemical resistance. The result: NO RUST\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating \"dead spots\" within the hood\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral vapor-proof fluorescent lighting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLarge capacity filtration bed to handle a wide variety of applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLab event timer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGas phase bonded carbon filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-lg-6\"\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient text-white h5 p-2\"\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter safety lockout to ensure correct filter replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirZone\u003csup\u003e™\u003c\/sup\u003e baffling to prevent fume hood roll and provide superior containment of gases and vapors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic gas detection for real-time gas phase filter monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTested to UL 61010-1 and CSA C22.2 No. 61010-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrushless, sparkless blower is post-filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeep base effectively contains accidental spills\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLow airflow alarm warns the user both visually and audibly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal time monitoring of installed filtration bed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sliderTable mt10 mb10 sliderTable-index0\"\u003e\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-3 text-white h5 p-2\"\u003e\u003cspan\u003eOptions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeck-mounted fixtures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccess port for electrical cords\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVented and unvented polypropylene base cabinets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSturdy stand with leveling feet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eULPA filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCustom access ports for routine equipment maintennce\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolypropylene laboratory sinks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eHow it Works\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cul class=\"list-group list-group-flush\"\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eA\u003c\/span\u003e\n\u003cp\u003eRoom air flows away from the operator and enters the enclosure in a horizontal pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eB\u003c\/span\u003e\n\u003cp\u003eRoom air mixes with both lighter and heavier gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eC\u003c\/span\u003e\n\u003cp\u003eMixed air is drawn into the AirZone™ baffling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eD\u003c\/span\u003e\n\u003cp\u003eContaminated air is directed through the filtration bed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eE\u003c\/span\u003e\n\u003cp\u003eClean air is recirculated into the room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003cimg alt=\"Air Flow Diagram\" src=\"https:\/\/www.aircleansystems.com\/img\/diagram\/airflow-diagram-03.svg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"table-responsive table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth rowspan=\"2\"\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eExternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC3000\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC3036\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC4000\u003c\/td\u003e\n\u003ctd\u003e1220mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC4036\u003c\/td\u003e\n\u003ctd\u003e1220mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC5000\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC5036\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC6000\u003c\/td\u003e\n\u003ctd\u003e1828mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC6036\u003c\/td\u003e\n\u003ctd\u003e1828mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eInternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC3000\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003ctd\u003e660mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC3036\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC4000\u003c\/td\u003e\n\u003ctd\u003e1194mm\u003c\/td\u003e\n\u003ctd\u003e660mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC4036\u003c\/td\u003e\n\u003ctd\u003e1194mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC5000\u003c\/td\u003e\n\u003ctd\u003e1499mm\u003c\/td\u003e\n\u003ctd\u003e660mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC5036\u003c\/td\u003e\n\u003ctd\u003e1499mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC6000\u003c\/td\u003e\n\u003ctd\u003e1803mm\u003c\/td\u003e\n\u003ctd\u003e660mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC6036\u003c\/td\u003e\n\u003ctd\u003e1803mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2022-07-09T18:34:34+12:00","created_at":"2022-07-09T18:31:35+12:00","vendor":"AirClean Systems","type":"Fume Hoods","tags":["Category_Fume Hoods","Features_Ductless","Manufacturer_Airclean Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44987427389736,"title":"Fumehoods \/ Ductless","option1":"Fumehoods","option2":"Ductless","option3":null,"sku":"AC4000S220","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AIRCLEAN SYSTEMS Polypropylene - Folding Sash Ductless - Fumehoods \/ Ductless","public_title":"Fumehoods \/ Ductless","options":["Fumehoods","Ductless"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-1.jpg?v=1675298699","\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-2.webp?v=1675298701","\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-3.webp?v=1675298703"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-1.jpg?v=1675298699","options":["Category","Features"],"media":[{"alt":null,"id":33102041743656,"position":1,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-1.jpg?v=1675298699"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-1.jpg?v=1675298699","width":700},{"alt":null,"id":33102041776424,"position":2,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-2.webp?v=1675298701"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-2.webp?v=1675298701","width":700},{"alt":null,"id":33102041841960,"position":3,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-3.webp?v=1675298703"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/polypropylene-ductless-fume-hood-folding-sash-3.webp?v=1675298703","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv class=\"o_g parameterList\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_g parameterList\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Parameters\u003c\/h2\u003e\n\u003cp\u003ePolypropylene ductless fume hoods protect both the operator and the environment by filtering toxic fumes, vapors, or gases through AirClean® Systems’ proprietary bonded carbon filtration. Standard with a thermally-fused integral spill tray, polypropylene ductless fume hoods are chemically resistant to virtually all corrosive applications.\u003c\/p\u003e\n\u003cp\u003eFor the widest application range possible, each polypropylene hood is designed to accommodate up to seven inches of filtration. By stacking a HEPA filter followed by a bonded carbon filter, the operator can effectively filter both toxic particulate and chemical fumes. For high evaporation or multi-chemical applications, a full seven-inch stack of chemical filtration may be recommended.\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-2 text-white h5 p-2\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirSafe® automatic safety controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral base with deep spill lip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo ductwork required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo installation required - plugs directly into a standard 110V or 220V electrical outlet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolypropylene construction for chemical resistance. The result: NO RUST\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating \"dead spots\" within the hood\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral vapor-proof fluorescent lighting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLarge capacity filtration bed to handle a wide variety of applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLab event timer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGas phase bonded carbon filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-lg-6\"\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient text-white h5 p-2\"\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter safety lockout to ensure correct filter replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirZone\u003csup\u003e™\u003c\/sup\u003e baffling to prevent fume hood roll and provide superior containment of gases and vapors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic gas detection for real-time gas phase filter monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTested to UL 61010-1 and CSA C22.2 No. 61010-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrushless, sparkless blower is post-filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeep base effectively contains accidental spills\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLow airflow alarm warns the user both visually and audibly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal time monitoring of installed filtration bed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sliderTable mt10 mb10 sliderTable-index0\"\u003e\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-3 text-white h5 p-2\"\u003e\u003cspan\u003eOptions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeck-mounted fixtures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccess port for electrical cords\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVented and unvented polypropylene base cabinets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSturdy stand with leveling feet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eULPA filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCustom access ports for routine equipment maintennce\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolypropylene laboratory sinks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eHow it Works\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cul class=\"list-group list-group-flush\"\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eA\u003c\/span\u003e\n\u003cp\u003eRoom air flows away from the operator and enters the enclosure in a horizontal pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eB\u003c\/span\u003e\n\u003cp\u003eRoom air mixes with both lighter and heavier gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eC\u003c\/span\u003e\n\u003cp\u003eMixed air is drawn into the AirZone™ baffling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eD\u003c\/span\u003e\n\u003cp\u003eContaminated air is directed through the filtration bed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eE\u003c\/span\u003e\n\u003cp\u003eClean air is recirculated into the room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003cimg alt=\"Air Flow Diagram\" src=\"https:\/\/www.aircleansystems.com\/img\/diagram\/airflow-diagram-03.svg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"table-responsive table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth rowspan=\"2\"\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eExternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC3000\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC3036\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC4000\u003c\/td\u003e\n\u003ctd\u003e1220mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC4036\u003c\/td\u003e\n\u003ctd\u003e1220mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC5000\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC5036\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC6000\u003c\/td\u003e\n\u003ctd\u003e1828mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC6036\u003c\/td\u003e\n\u003ctd\u003e1828mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1372mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eInternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC3000\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003ctd\u003e660mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC3036\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC4000\u003c\/td\u003e\n\u003ctd\u003e1194mm\u003c\/td\u003e\n\u003ctd\u003e660mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC4036\u003c\/td\u003e\n\u003ctd\u003e1194mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC5000\u003c\/td\u003e\n\u003ctd\u003e1499mm\u003c\/td\u003e\n\u003ctd\u003e660mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC5036\u003c\/td\u003e\n\u003ctd\u003e1499mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC6000\u003c\/td\u003e\n\u003ctd\u003e1803mm\u003c\/td\u003e\n\u003ctd\u003e660mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC6036\u003c\/td\u003e\n\u003ctd\u003e1803mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e889mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

AIRCLEAN SYSTEMS Polypropylene - Folding Sash Ductless

Product Description

Product Parameters

Polypropylene ductless fume hoods protect both the operator and the environment by filtering toxic fumes, vapors, or gases through AirClean® Systems’ proprietary bonded carbon filtration. Standard with a thermally-fused integral spill tray, polypropylene ductless fume hoods are chemically resistant to virtually all corrosive applications.

For the widest application range possible, each polypropylene hood is designed to accommodate up to seven inches of filtration. By stacking a HEPA filter followed by a bonded carbon filter, the operator can effectively filter both toxic particulate and chemical fumes. For high evaporation or multi-chemical applications, a full seven-inch stack of chemical filtration may be recommended.

Features
AirSafe® automatic safety controller
Integral base with deep spill lip
No ductwork required
No installation required - plugs directly into a standard 110V or 220V electrical outlet
Polypropylene construction for chemical resistance. The result: NO RUST
Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate
AirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating "dead spots" within the hood
Integral vapor-proof fluorescent lighting
Large capacity filtration bed to handle a wide variety of applications
Lab event timer
Gas phase bonded carbon filtration

Benefits
Filter safety lockout to ensure correct filter replacement
AirZone baffling to prevent fume hood roll and provide superior containment of gases and vapors
Electronic gas detection for real-time gas phase filter monitoring
Tested to UL 61010-1 and CSA C22.2 No. 61010-1
Brushless, sparkless blower is post-filter
Deep base effectively contains accidental spills
Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
Low airflow alarm warns the user both visually and audibly
Real time monitoring of installed filtration bed

Options
Deck-mounted fixtures
Access port for electrical cords
Vented and unvented polypropylene base cabinets
Sturdy stand with leveling feet
ULPA filter
Custom access ports for routine equipment maintennce
Polypropylene laboratory sinks

 

How it Works

  • A

    Room air flows away from the operator and enters the enclosure in a horizontal pattern.

  • B

    Room air mixes with both lighter and heavier gases.

  • C

    Mixed air is drawn into the AirZone™ baffling.

  • D

    Contaminated air is directed through the filtration bed.

  • E

    Clean air is recirculated into the room.

Air Flow Diagram
Product # External
Width Depth Height
AC3000 914mm 762mm 1372mm
AC3036 914mm 914mm 1372mm
AC4000 1220mm 762mm 1372mm
AC4036 1220mm 914mm 1372mm
AC5000 1524mm 762mm 1372mm
AC5036 1524mm 914mm 1372mm
AC6000 1828mm 914mm 1372mm
AC6036 1828mm 914mm 1372mm
Product # Internal
AC3000 889mm 660mm 889mm
AC3036 889mm 813mm 889mm
AC4000 1194mm 660mm 889mm
AC4036 1194mm 813mm 889mm
AC5000 1499mm 660mm 889mm
AC5036 1499mm 813mm 889mm
AC6000 1803mm 660mm 889mm
AC6036 1803mm 813mm 889mm

This product is available upon request. Contact us for more information.