Email info@acornsci.com for orders and inquiries.

{"id":6588960866403,"title":"IKA C 200","handle":"ika-c-200","description":"C 200-System consists of the following components: \u003cbr data-mce-fragment=\"1\"\u003eMeasuring cell C 200 \u003cbr data-mce-fragment=\"1\"\u003eDecomposition vessel C 5010 \u003cbr data-mce-fragment=\"1\"\u003eOxygen filling station C 248 \u003cbr data-mce-fragment=\"1\"\u003eConsumables for calibrations and installation \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eSpace-saving and low cost combustion calorimeter for determing gross calorific values of liquid and solid samples. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eValidation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eSuitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories with less analyses.. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eManual handling for water and oxygen filling. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eFour different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating tasks. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eClear and easily explained display which is simply to use . \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eWith an external power pack, \"world tension useable\" from 100 - 240 V AC, 50\/60 Hz. The operating voltage of the calorimeter is 24 V DC low- voltage. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eFriendly in aftersales \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eManual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minute. \u003cbr data-mce-fragment=\"1\"\u003eAll calculations have to be done manually. \u003cbr data-mce-fragment=\"1\"\u003eAt the other three modes ignition and calculation of the gross calorific value will be done automatically. \u003cbr data-mce-fragment=\"1\"\u003eThe gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe modes have different measuring times: \u003cbr data-mce-fragment=\"1\"\u003eIsoperibolic: approx: 17 min. \u003cbr data-mce-fragment=\"1\"\u003eDynamic : approx. 8 min \u003cbr data-mce-fragment=\"1\"\u003eManual : approx. 17 min \u003cbr data-mce-fragment=\"1\"\u003e(depend on the operator) \u003cbr data-mce-fragment=\"1\"\u003eTime controlled : 14 min \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe decomposition vessel can be equiped in to use an combustible crucibles C 14 \u003cbr data-mce-fragment=\"1\"\u003e(accessory C 5010.4 attachment is neessary) \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eUser-friendly software C 6040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible \u003cbr data-mce-fragment=\"1\"\u003eUp to eight IKA measuring cells can be controlled by a single PC, using a multiserial plug in card PCI 8.2 (accessory) \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cb data-mce-fragment=\"1\"\u003eScope of delivery\u003c\/b\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 5010 Decomposition vessel, standard\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 248 Oxygen filling station\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnation adapter\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200.1 Measuring cup 2000 ml\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWater emptying hose\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2021-06-09T12:13:41+12:00","created_at":"2021-06-09T12:13:40+12:00","vendor":"IKA","type":"Calorimeters","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Calorimeters"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417907970147,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA C 200","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/C200_1.jpg?v=1623197622","\/\/acornsci.co.nz\/cdn\/shop\/products\/C200_2.jpg?v=1623197622"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200_1.jpg?v=1623197622","options":["Title"],"media":[{"alt":null,"id":20603842855011,"position":1,"preview_image":{"aspect_ratio":1.185,"height":844,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200_1.jpg?v=1623197622"},"aspect_ratio":1.185,"height":844,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200_1.jpg?v=1623197622","width":1000},{"alt":null,"id":20603842887779,"position":2,"preview_image":{"aspect_ratio":1.174,"height":852,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200_2.jpg?v=1623197622"},"aspect_ratio":1.174,"height":852,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200_2.jpg?v=1623197622","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"C 200-System consists of the following components: \u003cbr data-mce-fragment=\"1\"\u003eMeasuring cell C 200 \u003cbr data-mce-fragment=\"1\"\u003eDecomposition vessel C 5010 \u003cbr data-mce-fragment=\"1\"\u003eOxygen filling station C 248 \u003cbr data-mce-fragment=\"1\"\u003eConsumables for calibrations and installation \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eSpace-saving and low cost combustion calorimeter for determing gross calorific values of liquid and solid samples. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eValidation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eSuitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories with less analyses.. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eManual handling for water and oxygen filling. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eFour different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating tasks. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eClear and easily explained display which is simply to use . \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eWith an external power pack, \"world tension useable\" from 100 - 240 V AC, 50\/60 Hz. The operating voltage of the calorimeter is 24 V DC low- voltage. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eFriendly in aftersales \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eManual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minute. \u003cbr data-mce-fragment=\"1\"\u003eAll calculations have to be done manually. \u003cbr data-mce-fragment=\"1\"\u003eAt the other three modes ignition and calculation of the gross calorific value will be done automatically. \u003cbr data-mce-fragment=\"1\"\u003eThe gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe modes have different measuring times: \u003cbr data-mce-fragment=\"1\"\u003eIsoperibolic: approx: 17 min. \u003cbr data-mce-fragment=\"1\"\u003eDynamic : approx. 8 min \u003cbr data-mce-fragment=\"1\"\u003eManual : approx. 17 min \u003cbr data-mce-fragment=\"1\"\u003e(depend on the operator) \u003cbr data-mce-fragment=\"1\"\u003eTime controlled : 14 min \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe decomposition vessel can be equiped in to use an combustible crucibles C 14 \u003cbr data-mce-fragment=\"1\"\u003e(accessory C 5010.4 attachment is neessary) \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eUser-friendly software C 6040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible \u003cbr data-mce-fragment=\"1\"\u003eUp to eight IKA measuring cells can be controlled by a single PC, using a multiserial plug in card PCI 8.2 (accessory) \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cb data-mce-fragment=\"1\"\u003eScope of delivery\u003c\/b\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 5010 Decomposition vessel, standard\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 248 Oxygen filling station\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnation adapter\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200.1 Measuring cup 2000 ml\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWater emptying hose\u003c\/li\u003e\n\u003c\/ul\u003e"}
Product Description
C 200-System consists of the following components:
Measuring cell C 200
Decomposition vessel C 5010
Oxygen filling station C 248
Consumables for calibrations and installation

Space-saving and low cost combustion calorimeter for determing gross calorific values of liquid and solid samples.

Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.

Suitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories with less analyses..

Manual handling for water and oxygen filling.

Four different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating tasks.

Clear and easily explained display which is simply to use .

With an external power pack, "world tension useable" from 100 - 240 V AC, 50/60 Hz. The operating voltage of the calorimeter is 24 V DC low- voltage.

Friendly in aftersales

Manual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minute.
All calculations have to be done manually.
At the other three modes ignition and calculation of the gross calorific value will be done automatically.
The gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually.

The modes have different measuring times:
Isoperibolic: approx: 17 min.
Dynamic : approx. 8 min
Manual : approx. 17 min
(depend on the operator)
Time controlled : 14 min

The decomposition vessel can be equiped in to use an combustible crucibles C 14
(accessory C 5010.4 attachment is neessary)

User-friendly software C 6040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible
Up to eight IKA measuring cells can be controlled by a single PC, using a multiserial plug in card PCI 8.2 (accessory)


Scope of delivery
  • C 200
  • C 5010 Decomposition vessel, standard
  • C 248 Oxygen filling station
  • Ignation adapter
  • C 200.1 Measuring cup 2000 ml
  • Water emptying hose
Vendor: IKA

This product is available upon request. Contact us for more information.