{"id":6588961947747,"title":"IKA C 200 h","handle":"ika-c-200-h","description":"The C 200 h package is designed for teaching and training purposes at technical schools and universities. Due to its semi-automated isoperibol mode it is also perfectly suitable for industrial laboratories with low number of analyses. The space-saving and standard-conforming combustion calorimeter determines the gross calorific value of liquid and solid samples. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe scope of delivery includes: \u003cbr data-mce-fragment=\"1\"\u003eC 200 calorimeter measuring cell \u003cbr data-mce-fragment=\"1\"\u003eC 5012 halogen resistant, catalytic activated decomposition vessel \u003cbr data-mce-fragment=\"1\"\u003eC 200.2 conversion kit for C 5012 \u003cbr data-mce-fragment=\"1\"\u003eC 248 oxygen filling station \u003cbr data-mce-fragment=\"1\"\u003eConsumables for calibration and installation \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe water and oxygen handling is conducted manually. In case of an increasing amount of measurements the water handling system can be further automated. For that purpose, the C 200.RC hose set as well as the RC 2 basic recirculating chiller are required. Both accessories are available separately. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe catalytic activated, halogen resistant decomposition vessel C 5012 is specifically designed for the combustion of samples that contain halogens and sulfur ( \u0026gt; 3 % ). The material of the decomposition vessel (Hastelloy) prevents corrosion caused by samples with high chlorine content. The catalytic activated inner-surface leads to higher recovery rates in case analysis of halogens and\/or sulfur is required after the combustion. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eFour different operation modes enable the user to control the measuring times according to individual requirements: \u003cbr data-mce-fragment=\"1\"\u003eIsoperibol: approx: 17 min. \u003cbr data-mce-fragment=\"1\"\u003eDynamic: approx. 8 min \u003cbr data-mce-fragment=\"1\"\u003eManual: approx. 17 min (depends on the operator) \u003cbr data-mce-fragment=\"1\"\u003eTime controlled: 14 min \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eMeasurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe software C 6040 CalWin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. CalWin is sold separately. \u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cb data-mce-fragment=\"1\"\u003eScope of delivery\u003c\/b\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 5012 Decomposition vessel, halogen resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200.2 Conversion kit for C 5012\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 248 Oxygen filling station\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnation adapter\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200.1 Measuring cup 2000 ml\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWater emptying hose\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2021-06-09T12:19:17+12:00","created_at":"2021-06-09T12:19:15+12:00","vendor":"IKA","type":"Calorimeters","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Calorimeters"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417913770083,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA C 200 h","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/C200h_1.jpg?v=1623197958","\/\/acornsci.co.nz\/cdn\/shop\/products\/C200h_2.jpg?v=1623197958"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200h_1.jpg?v=1623197958","options":["Title"],"media":[{"alt":null,"id":20603855568995,"position":1,"preview_image":{"aspect_ratio":1.185,"height":844,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200h_1.jpg?v=1623197958"},"aspect_ratio":1.185,"height":844,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200h_1.jpg?v=1623197958","width":1000},{"alt":null,"id":20603855601763,"position":2,"preview_image":{"aspect_ratio":1.174,"height":852,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200h_2.jpg?v=1623197958"},"aspect_ratio":1.174,"height":852,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C200h_2.jpg?v=1623197958","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"The C 200 h package is designed for teaching and training purposes at technical schools and universities. Due to its semi-automated isoperibol mode it is also perfectly suitable for industrial laboratories with low number of analyses. The space-saving and standard-conforming combustion calorimeter determines the gross calorific value of liquid and solid samples. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe scope of delivery includes: \u003cbr data-mce-fragment=\"1\"\u003eC 200 calorimeter measuring cell \u003cbr data-mce-fragment=\"1\"\u003eC 5012 halogen resistant, catalytic activated decomposition vessel \u003cbr data-mce-fragment=\"1\"\u003eC 200.2 conversion kit for C 5012 \u003cbr data-mce-fragment=\"1\"\u003eC 248 oxygen filling station \u003cbr data-mce-fragment=\"1\"\u003eConsumables for calibration and installation \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe water and oxygen handling is conducted manually. In case of an increasing amount of measurements the water handling system can be further automated. For that purpose, the C 200.RC hose set as well as the RC 2 basic recirculating chiller are required. Both accessories are available separately. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe catalytic activated, halogen resistant decomposition vessel C 5012 is specifically designed for the combustion of samples that contain halogens and sulfur ( \u0026gt; 3 % ). The material of the decomposition vessel (Hastelloy) prevents corrosion caused by samples with high chlorine content. The catalytic activated inner-surface leads to higher recovery rates in case analysis of halogens and\/or sulfur is required after the combustion. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eFour different operation modes enable the user to control the measuring times according to individual requirements: \u003cbr data-mce-fragment=\"1\"\u003eIsoperibol: approx: 17 min. \u003cbr data-mce-fragment=\"1\"\u003eDynamic: approx. 8 min \u003cbr data-mce-fragment=\"1\"\u003eManual: approx. 17 min (depends on the operator) \u003cbr data-mce-fragment=\"1\"\u003eTime controlled: 14 min \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eMeasurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe software C 6040 CalWin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. CalWin is sold separately. \u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cb data-mce-fragment=\"1\"\u003eScope of delivery\u003c\/b\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 5012 Decomposition vessel, halogen resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200.2 Conversion kit for C 5012\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 248 Oxygen filling station\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnation adapter\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 200.1 Measuring cup 2000 ml\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWater emptying hose\u003c\/li\u003e\n\u003c\/ul\u003e"}
Product Description
The C 200 h package is designed for teaching and training purposes at technical schools and universities. Due to its semi-automated isoperibol mode it is also perfectly suitable for industrial laboratories with low number of analyses. The space-saving and standard-conforming combustion calorimeter determines the gross calorific value of liquid and solid samples.

The scope of delivery includes:
C 200 calorimeter measuring cell
C 5012 halogen resistant, catalytic activated decomposition vessel
C 200.2 conversion kit for C 5012
C 248 oxygen filling station
Consumables for calibration and installation

The water and oxygen handling is conducted manually. In case of an increasing amount of measurements the water handling system can be further automated. For that purpose, the C 200.RC hose set as well as the RC 2 basic recirculating chiller are required. Both accessories are available separately.

The catalytic activated, halogen resistant decomposition vessel C 5012 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). The material of the decomposition vessel (Hastelloy) prevents corrosion caused by samples with high chlorine content. The catalytic activated inner-surface leads to higher recovery rates in case analysis of halogens and/or sulfur is required after the combustion.

Four different operation modes enable the user to control the measuring times according to individual requirements:
Isoperibol: approx: 17 min.
Dynamic: approx. 8 min
Manual: approx. 17 min (depends on the operator)
Time controlled: 14 min

Measurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.

The software C 6040 CalWin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. CalWin is sold separately.

Scope of delivery
  • C 200
  • C 5012 Decomposition vessel, halogen resistant
  • C 200.2 Conversion kit for C 5012
  • C 248 Oxygen filling station
  • Ignation adapter
  • C 200.1 Measuring cup 2000 ml
  • Water emptying hose