{"id":1582177477,"title":"HANNA HI 2314-02 Benchtop Conductivity Meter with MTC","handle":"hi-2314-02","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eThe \u003cspan id=\"cqq04270h2a_1\" class=\"cqq04270h2a\"\u003eHanna Instruments\u003c\/span\u003e HI 2314 Conductivity Meter with Manual Temperature Compensation (MTC) provides a simple to use. cost effective method of measuring Conductivity. \u003c\/p\u003e\n\u003cp\u003eThe HI 2314 utilizes a four ring potentiometric probe with a platinum sensor that offers wider measurement ranges and increased accuracy over amperometric designs.\u003c\/p\u003e\n\u003cp\u003eA potentiometric probe works on the principal of induction which eliminates the effects of polarization (a common problem of amperometric systems). Two outer rings apply an alternating voltage and induce a current loop in the solution while two inner rings measure the voltage drop induced by the current loop (which is dependent on the conductivity of the solution). By utilizing the 4-ring method. it is possible to measure from very low to very high conductivity levels (up to 200 mS\/cm) without changing probes.\u003c\/p\u003e\n\u003cp\u003eFEATURES\/BENEFITS:\u003cbr\u003e\u003cbr\u003e* Four ring potentiometric platinum probe\u003cbr\u003e* Four measurement ranges\u003cbr\u003e* ±1% F.S. Accuracy\u003cbr\u003e* Manual Calibration\u003cbr\u003e* Manual \u003cspan id=\"cqq04270h2a_2\" class=\"cqq04270h2a\"\u003eTemperature Compensation\u003c\/span\u003e (MTC)\u003cbr\u003e* Large LCD\u003cbr\u003e* Built-in Solution Holders\u003cbr\u003e \u003cbr\u003eFEATURES IN DEPTH:\u003cbr\u003e\u003cbr\u003eFour Ring Probe - A four ring potentiometric probe using 1 probe for 4 ranges. (The ranges are: 0.0 to 199.9 ?s\/cm; 0 to 1999 ?s\/cm; 0.00 to 19.99 ms\/cm; 0.0 to 199.9 ms\/cm). The probe prevents a polarization effect.\u003c\/p\u003e\n\u003cp\u003eManual Calibration - This simple to use feature can be calibrated to any value within the measurement ranges and is less expensive than models with auto-calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eManual Temperature Compensation (MTC) – MTC provides the ability to demonstrate the effect of temperature on EC measurement. It is simple to use and allows for different temperature corrections based on the sample being tested.\u003c\/p\u003e\n\u003cp\u003eLarge LCD – The new. larger LCD is bright and easy to read.\u003c\/p\u003e\n\u003cp\u003eBuilt-in Solution Holders – The HI 2315 has solution holders built into the casing. This convenient feature saves space and prevents solutions from tipping over.\u003c\/p\u003e\n\u003cp\u003eRecessed Connector Bay – Protects connectors from liquids.\u003c\/p\u003e\n\u003cp\u003ePRIMARY APPLICATIONS:\u003cbr\u003e\u003cbr\u003e* Municipal \u003cspan id=\"cqq04270h2a_3\" class=\"cqq04270h2a\"\u003edrinking water\u003c\/span\u003e. environmental studies\u003cbr\u003e* Printing industry - Fountain solution maintenance\u003cbr\u003e* Water Treatment – Boiler\/Cooling Tower water quality\u003cbr\u003e* Agriculture – Fertilizer concentration\u003cbr\u003e* Food processing – salt levels in food. (i.e. making pickles)\u003cbr\u003e* Education – Teach students about EC\u003c\/p\u003e\n\u003cp\u003eElectrodes\u003cbr\u003eHI 76300 Platinum 4-Ring Potentiometric Conductivity Probe. DIN connector and 1 m (3.3’) cable\u003cbr\u003eSolutions\u003cbr\u003eHI 5030-12 12880 ?S\/cm EC Solution (120ml)\u003cbr\u003eHI 5031-12 1413 ?S\/cm EC Solution (120ml)\u003cbr\u003eHI 5033-12 84 ?S\/cm EC Solution (120ml)\u003cbr\u003eHI 5034-12 80000 ?S\/cm EC Solution (120ml)\u003cbr\u003eHI 7035L 111800 ?S\/cm EC Solution (500ml)\u003cbr\u003eHI 7039L 5000 ?S\/cm EC Solution (500ml)\u003cbr\u003eHI 7061L Cleaning Solution (500ml)\u003c\/p\u003e\n\u003cp\u003eAccessories\u003cbr\u003eHI 76404 Electrode Holder\u003cbr\u003eHI 710005 Power Adapter. 115 Vac to 12 VDC. US Plug\u003cbr\u003eHI 710006 Power Adapter. 230 Vac to 12 VDC. European Plug\u003cbr\u003eHI 740036P 100 mL Plastic Beaker\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 2314-01 (115V) and HI 2314-02 (230V) are supplied with HI 76300 conductivity probe. 12 VDC adapter and instruction manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 µs\/cm; 0 to 1999 µs\/cm; 0.00 to 19.99 ms\/cm; 0.0 to 199.9 ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 µs\/cm; 1 µs\/cm; 0.01 ms\/cm; 0.1 ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy (@20°C\/68°F)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1% F.S. (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManual. one point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManual. 0 to 50°C (32 to 122°F) with b = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76300. platinum four ring conductivity probe with internal temperature sensor. Din connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:09:22+12:00","created_at":"2015-09-01T15:17:14+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters"],"price":133000,"price_min":133000,"price_max":133000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857316229,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI2314-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 2314-02 Benchtop Conductivity Meter with MTC","public_title":null,"options":["Default Title"],"price":133000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2314v2-200_2015.jpeg?v=1465536557"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2314v2-200_2015.jpeg?v=1465536557","options":["Title"],"media":[{"alt":"HI 2314-02 Benchtop Conductivity Meter with MTC - Acorn Scientific","id":21304279139,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2314v2-200_2015.jpeg?v=1465536557"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2314v2-200_2015.jpeg?v=1465536557","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eThe \u003cspan id=\"cqq04270h2a_1\" class=\"cqq04270h2a\"\u003eHanna Instruments\u003c\/span\u003e HI 2314 Conductivity Meter with Manual Temperature Compensation (MTC) provides a simple to use. cost effective method of measuring Conductivity. \u003c\/p\u003e\n\u003cp\u003eThe HI 2314 utilizes a four ring potentiometric probe with a platinum sensor that offers wider measurement ranges and increased accuracy over amperometric designs.\u003c\/p\u003e\n\u003cp\u003eA potentiometric probe works on the principal of induction which eliminates the effects of polarization (a common problem of amperometric systems). Two outer rings apply an alternating voltage and induce a current loop in the solution while two inner rings measure the voltage drop induced by the current loop (which is dependent on the conductivity of the solution). By utilizing the 4-ring method. it is possible to measure from very low to very high conductivity levels (up to 200 mS\/cm) without changing probes.\u003c\/p\u003e\n\u003cp\u003eFEATURES\/BENEFITS:\u003cbr\u003e\u003cbr\u003e* Four ring potentiometric platinum probe\u003cbr\u003e* Four measurement ranges\u003cbr\u003e* ±1% F.S. Accuracy\u003cbr\u003e* Manual Calibration\u003cbr\u003e* Manual \u003cspan id=\"cqq04270h2a_2\" class=\"cqq04270h2a\"\u003eTemperature Compensation\u003c\/span\u003e (MTC)\u003cbr\u003e* Large LCD\u003cbr\u003e* Built-in Solution Holders\u003cbr\u003e \u003cbr\u003eFEATURES IN DEPTH:\u003cbr\u003e\u003cbr\u003eFour Ring Probe - A four ring potentiometric probe using 1 probe for 4 ranges. (The ranges are: 0.0 to 199.9 ?s\/cm; 0 to 1999 ?s\/cm; 0.00 to 19.99 ms\/cm; 0.0 to 199.9 ms\/cm). The probe prevents a polarization effect.\u003c\/p\u003e\n\u003cp\u003eManual Calibration - This simple to use feature can be calibrated to any value within the measurement ranges and is less expensive than models with auto-calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eManual Temperature Compensation (MTC) – MTC provides the ability to demonstrate the effect of temperature on EC measurement. It is simple to use and allows for different temperature corrections based on the sample being tested.\u003c\/p\u003e\n\u003cp\u003eLarge LCD – The new. larger LCD is bright and easy to read.\u003c\/p\u003e\n\u003cp\u003eBuilt-in Solution Holders – The HI 2315 has solution holders built into the casing. This convenient feature saves space and prevents solutions from tipping over.\u003c\/p\u003e\n\u003cp\u003eRecessed Connector Bay – Protects connectors from liquids.\u003c\/p\u003e\n\u003cp\u003ePRIMARY APPLICATIONS:\u003cbr\u003e\u003cbr\u003e* Municipal \u003cspan id=\"cqq04270h2a_3\" class=\"cqq04270h2a\"\u003edrinking water\u003c\/span\u003e. environmental studies\u003cbr\u003e* Printing industry - Fountain solution maintenance\u003cbr\u003e* Water Treatment – Boiler\/Cooling Tower water quality\u003cbr\u003e* Agriculture – Fertilizer concentration\u003cbr\u003e* Food processing – salt levels in food. (i.e. making pickles)\u003cbr\u003e* Education – Teach students about EC\u003c\/p\u003e\n\u003cp\u003eElectrodes\u003cbr\u003eHI 76300 Platinum 4-Ring Potentiometric Conductivity Probe. DIN connector and 1 m (3.3’) cable\u003cbr\u003eSolutions\u003cbr\u003eHI 5030-12 12880 ?S\/cm EC Solution (120ml)\u003cbr\u003eHI 5031-12 1413 ?S\/cm EC Solution (120ml)\u003cbr\u003eHI 5033-12 84 ?S\/cm EC Solution (120ml)\u003cbr\u003eHI 5034-12 80000 ?S\/cm EC Solution (120ml)\u003cbr\u003eHI 7035L 111800 ?S\/cm EC Solution (500ml)\u003cbr\u003eHI 7039L 5000 ?S\/cm EC Solution (500ml)\u003cbr\u003eHI 7061L Cleaning Solution (500ml)\u003c\/p\u003e\n\u003cp\u003eAccessories\u003cbr\u003eHI 76404 Electrode Holder\u003cbr\u003eHI 710005 Power Adapter. 115 Vac to 12 VDC. US Plug\u003cbr\u003eHI 710006 Power Adapter. 230 Vac to 12 VDC. European Plug\u003cbr\u003eHI 740036P 100 mL Plastic Beaker\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 2314-01 (115V) and HI 2314-02 (230V) are supplied with HI 76300 conductivity probe. 12 VDC adapter and instruction manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 µs\/cm; 0 to 1999 µs\/cm; 0.00 to 19.99 ms\/cm; 0.0 to 199.9 ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 µs\/cm; 1 µs\/cm; 0.01 ms\/cm; 0.1 ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy (@20°C\/68°F)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1% F.S. (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManual. one point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManual. 0 to 50°C (32 to 122°F) with b = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76300. platinum four ring conductivity probe with internal temperature sensor. Din connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}
HANNA HI 2314-02 Benchtop Conductivity Meter with MTC
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














