Email info@acornsci.com for orders and inquiries.

{"id":1582172869,"title":"HANNA HI 2223-02 Calibration Check™ pH\/ORP\/Temperature Benchtop Meter with extended pH range","handle":"hi2223-02","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003epH Calibration Check™\u003c\/li\u003e\n\u003cli\u003eOn-screen electrode condition and response time\u003c\/li\u003e\n\u003cli\u003eUp to five point calibration with seven standard buffers\u003c\/li\u003e\n\u003cli\u003eDiagnostic alerts through icons\u003c\/li\u003e\n\u003cli\u003eAutomatic \u003cspan id=\"gvow3532ka0_1\" class=\"gvow3532ka0\"\u003eTemperature Compensation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eLog up to 500 samples\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003ePC \u003cspan id=\"gvow3532ka0_2\" class=\"gvow3532ka0\"\u003einterface\u003c\/span\u003e via US\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA properly manufactured and maintained pH electrode will retain its measuring integrity for a long time. As a result of many factors such as age. poor maintenance or improper handling. any electrode in time will lose its integrity.\u003c\/p\u003e\n\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note. because during calibration. the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration.\u003c\/p\u003e\n\u003cp\u003eA dirty electrode or wrong calibration approach can contribute to buffer solution contamination. A contaminated buffer solution can present a major problem during calibration due to the fact that it is considered the only reference.\u003c\/p\u003e\n\u003cp\u003eThe HI 2223 is a pH \u003cspan id=\"gvow3532ka0_3\" class=\"gvow3532ka0\"\u003ebenchtop\u003c\/span\u003e meter featuring our exclusive Calibration Check™ diagnostics for both pH?electrodes and buffer solutions during calibration. This instrument compares the characteristics of the pH electrode from one calibration to the next. In the case of large variances in the electrode condition. it alerts the user that the electrode needs to be properly cleaned prior to calibration and measuring.\u003c\/p\u003e\n\u003cp\u003eThe second feature is to detect if the calibration buffer solution is contaminated. After calibration. the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.\u003c\/p\u003e\n\u003cp\u003eThis meter can measure using ORP electrodes (pH channel input). due to it’s capability to measure mV with a resolution up to 0.1 mV.\u003c\/p\u003e\n\u003cp\u003eHI 2223 also features five point calibration with seven standard buffers. Automatic Temperature Compensation and GLP capabilities that allow for the storage and retrieval of all data regarding pH. With a built-in logging function. measurements are stored in non volatile memory and can be transferred to a PC through the USB port. Users can manually log up to 200 records and interval log up to 500 records.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 2223-01 (115V) and HI 2223-02 (230V) are supplied with HI 1131B pH electrode. HI 7662 temperature probe. HI 76404N electrode holder. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700661 cleaning solution sachet. HI 7071S electrolyte solution (30 mL). 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e–2.00 to 16.00 pH; –2.000 to 16.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±999.9 mV; ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e– 20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e0.1mV(± 999.9mV); 1mV(± 2000mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±0.2mV(± 999.9mV);\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e± 0.2 °C (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUp to 5 point calibration. 7 standard buffers available (1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManual or automatic from -20 to 120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1131P glass body. single junction. refillable with BNC connection and 1 m (3.3') Cable HI 7662 stainless steel probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e235 x 222 x 109 mm (9.2 x 8.7 x 4.3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.3 kg (2.9 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%201131P\"\u003eHI 1131P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefillable. Combination pH Electrode for the Laboratory and Beer Testing\u003cbr\u003e\u003csmall\u003eBNC + pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207004L\"\u003eHI 7004L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207007L\"\u003eHI 7007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207010L\"\u003eHI 7010L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%2076404N\"\u003eHI 76404N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Holder for HI 42xx Type Bench Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207662\"\u003eHI 7662\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eORP Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207091L\"\u003eHI 7091L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eReducing Pretreatment Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207092L\"\u003eHI 7092L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOxidizing Pretreatment Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:09:42+12:00","created_at":"2015-09-01T15:16:38+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters","Type_pH \u0026 ORP Meters","Type_Thermometers"],"price":96521,"price_min":96521,"price_max":96521,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857306181,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI2223-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 2223-02 Calibration Check™ pH\/ORP\/Temperature Benchtop Meter with extended pH range","public_title":null,"options":["Default Title"],"price":96521,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2223_200_2015.jpeg?v=1465536554"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2223_200_2015.jpeg?v=1465536554","options":["Title"],"media":[{"alt":"HI 2223-02 Calibration Check™ pH\/ORP\/Temperature Benchtop Meter with extended pH range - Acorn Scientific","id":21302739043,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2223_200_2015.jpeg?v=1465536554"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2223_200_2015.jpeg?v=1465536554","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003epH Calibration Check™\u003c\/li\u003e\n\u003cli\u003eOn-screen electrode condition and response time\u003c\/li\u003e\n\u003cli\u003eUp to five point calibration with seven standard buffers\u003c\/li\u003e\n\u003cli\u003eDiagnostic alerts through icons\u003c\/li\u003e\n\u003cli\u003eAutomatic \u003cspan id=\"gvow3532ka0_1\" class=\"gvow3532ka0\"\u003eTemperature Compensation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eLog up to 500 samples\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003ePC \u003cspan id=\"gvow3532ka0_2\" class=\"gvow3532ka0\"\u003einterface\u003c\/span\u003e via US\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA properly manufactured and maintained pH electrode will retain its measuring integrity for a long time. As a result of many factors such as age. poor maintenance or improper handling. any electrode in time will lose its integrity.\u003c\/p\u003e\n\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note. because during calibration. the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration.\u003c\/p\u003e\n\u003cp\u003eA dirty electrode or wrong calibration approach can contribute to buffer solution contamination. A contaminated buffer solution can present a major problem during calibration due to the fact that it is considered the only reference.\u003c\/p\u003e\n\u003cp\u003eThe HI 2223 is a pH \u003cspan id=\"gvow3532ka0_3\" class=\"gvow3532ka0\"\u003ebenchtop\u003c\/span\u003e meter featuring our exclusive Calibration Check™ diagnostics for both pH?electrodes and buffer solutions during calibration. This instrument compares the characteristics of the pH electrode from one calibration to the next. In the case of large variances in the electrode condition. it alerts the user that the electrode needs to be properly cleaned prior to calibration and measuring.\u003c\/p\u003e\n\u003cp\u003eThe second feature is to detect if the calibration buffer solution is contaminated. After calibration. the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.\u003c\/p\u003e\n\u003cp\u003eThis meter can measure using ORP electrodes (pH channel input). due to it’s capability to measure mV with a resolution up to 0.1 mV.\u003c\/p\u003e\n\u003cp\u003eHI 2223 also features five point calibration with seven standard buffers. Automatic Temperature Compensation and GLP capabilities that allow for the storage and retrieval of all data regarding pH. With a built-in logging function. measurements are stored in non volatile memory and can be transferred to a PC through the USB port. Users can manually log up to 200 records and interval log up to 500 records.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 2223-01 (115V) and HI 2223-02 (230V) are supplied with HI 1131B pH electrode. HI 7662 temperature probe. HI 76404N electrode holder. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700661 cleaning solution sachet. HI 7071S electrolyte solution (30 mL). 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e–2.00 to 16.00 pH; –2.000 to 16.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±999.9 mV; ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e– 20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e0.1mV(± 999.9mV); 1mV(± 2000mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±0.2mV(± 999.9mV);\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e± 0.2 °C (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUp to 5 point calibration. 7 standard buffers available (1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManual or automatic from -20 to 120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1131P glass body. single junction. refillable with BNC connection and 1 m (3.3') Cable HI 7662 stainless steel probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e235 x 222 x 109 mm (9.2 x 8.7 x 4.3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.3 kg (2.9 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%201131P\"\u003eHI 1131P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefillable. Combination pH Electrode for the Laboratory and Beer Testing\u003cbr\u003e\u003csmall\u003eBNC + pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207004L\"\u003eHI 7004L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207007L\"\u003eHI 7007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207010L\"\u003eHI 7010L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%2076404N\"\u003eHI 76404N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Holder for HI 42xx Type Bench Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207662\"\u003eHI 7662\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eORP Calibration Solutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207091L\"\u003eHI 7091L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eReducing Pretreatment Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044006\u0026amp;ProdCode=HI%207092L\"\u003eHI 7092L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOxidizing Pretreatment Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 2223-02 Calibration Check™ pH/ORP/Temperature Benchtop Meter with extended pH range

Product Description

 

  • pH Calibration Check™
  • On-screen electrode condition and response time
  • Up to five point calibration with seven standard buffers
  • Diagnostic alerts through icons
  • Automatic Temperature Compensation
  • Log up to 500 samples
  • GLP features
  • PC interface via US

 

A properly manufactured and maintained pH electrode will retain its measuring integrity for a long time. As a result of many factors such as age. poor maintenance or improper handling. any electrode in time will lose its integrity.

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note. because during calibration. the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration.

A dirty electrode or wrong calibration approach can contribute to buffer solution contamination. A contaminated buffer solution can present a major problem during calibration due to the fact that it is considered the only reference.

The HI 2223 is a pH benchtop meter featuring our exclusive Calibration Check™ diagnostics for both pH?electrodes and buffer solutions during calibration. This instrument compares the characteristics of the pH electrode from one calibration to the next. In the case of large variances in the electrode condition. it alerts the user that the electrode needs to be properly cleaned prior to calibration and measuring.

The second feature is to detect if the calibration buffer solution is contaminated. After calibration. the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.

This meter can measure using ORP electrodes (pH channel input). due to it’s capability to measure mV with a resolution up to 0.1 mV.

HI 2223 also features five point calibration with seven standard buffers. Automatic Temperature Compensation and GLP capabilities that allow for the storage and retrieval of all data regarding pH. With a built-in logging function. measurements are stored in non volatile memory and can be transferred to a PC through the USB port. Users can manually log up to 200 records and interval log up to 500 records.

 

Order Information:
HI 2223-01 (115V) and HI 2223-02 (230V) are supplied with HI 1131B pH electrode. HI 7662 temperature probe. HI 76404N electrode holder. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700661 cleaning solution sachet. HI 7071S electrolyte solution (30 mL). 12 VDC adapter and instructions.

SPECIFICATIONS:

Range pH –2.00 to 16.00 pH; –2.000 to 16.000 pH
  mV ±999.9 mV; ±2000 mV
  Temperature – 20.0 to 120.0 °C
Resolution pH 0.01 pH; 0.001 pH
  mV 0.1mV(± 999.9mV); 1mV(± 2000mV)
  Temperature 0.1 °C
Accuracy pH ±0.01 pH; ±0.002 pH
  mV ±0.2mV(± 999.9mV);
  Temperature ± 0.2 °C (excluding probe error)
pH Calibration   Up to 5 point calibration. 7 standard buffers available (1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45)
Temperature Compensation   Manual or automatic from -20 to 120°C
Temperature Probe   HI 1131P glass body. single junction. refillable with BNC connection and 1 m (3.3') Cable HI 7662 stainless steel probe
PC Connection   USB
Data Logging   500 points
Dimensions   235 x 222 x 109 mm (9.2 x 8.7 x 4.3")
Weight   1.3 kg (2.9 lb.)
Electrodes
HI 1131P Refillable. Combination pH Electrode for the Laboratory and Beer Testing
BNC + pin Connection
Solutions
HI 70300L Electrode Storage Solution
1 x 500 mL bottle
HI 7004L 4.01 pH Buffer Solution
1 x 500 mL bottle
HI 7007L 7.01 pH Buffer Solution
1 x 500 mL bottle
HI 7010L 10.01 pH Buffer Solution
1 x 500 mL bottle
Accessories
HI 92000 Windows® Compatible Software
HI 76404N Electrode Holder for HI 42xx Type Bench Meters
Probes
HI 7662 Stainless Steel Temperature Probe
ORP Calibration Solutions
HI 7091L Reducing Pretreatment Solution
1 x 500 mL bottle
HI 7092L Oxidizing Pretreatment Solution
1 x 500 mL bottle

This product is available upon request. Contact us for more information.