{"id":1582172805,"title":"HANNA HI 2222-02 Wine Analysis pH Benchtop Meter","handle":"hi12222-02","description":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for wine analysis\u003c\/li\u003e\n\u003cli\u003eDedicated 3.00 pH buffer for calibration in the wine pH range\u003c\/li\u003e\n\u003cli\u003eClog-resistant electrode\u003c\/li\u003e\n\u003cli\u003epH Calibration Check™ electrode diagnostics\u003c\/li\u003e\n\u003cli\u003eElectrode condition on display \u003c\/li\u003e\n\u003cli\u003eCalibration alarm timeout\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003ePC interface via USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 2222 is the only pH meter on the market today that allows for automatic pH calibration at pH 3 and pH 7. With the dedicated 3.00 pH buffer for wine calibration in the wine pH range. any error due to calibration will be minimized. The HI 2222’s Calibration Check™ diagnostics along with the included HI 1048P clogging resistant pH electode further enhances measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eThis wine analysis instrument also features logging of up to 100 samples. GLP (\u003cspan id=\"gvow3532ka0_1\" class=\"gvow3532ka0\"\u003eGood Laboratory Practice\u003c\/span\u003e) capability. and a USB interface for the transfer of data to a PC.\u003cbr\u003eIn the process of \u003cspan id=\"gvow3532ka0_2\" class=\"gvow3532ka0\"\u003ewine making\u003c\/span\u003e. most pH measurements are made in the must. A pH electrode gets dirty quickly when measuring the pH of must because sediments build up on both the pH measuring bulb and pH electrode junction. This becomes a big problem during the actual pH measurement if the electrode has not been properly cleaned. A dirty pH electrode can give results that are up to 0.5 pH inaccurate — even after a pH calibration has just been performed.\u003c\/p\u003e\n\u003cp\u003eConventional pH meters do not warn the user when the pH electrode is dirty. A common example of this occurs just after calibrating the instrument — the pH electrode is immersed into the pH 7 buffer and the reading is lower than expected (pH 6.8 or 6.9 instead of 7.0). HI 2222 uses HANNA ’s unique technology to detect when the electrode is dirty and gives a warning during calibration.\u003c\/p\u003e\n\u003cp\u003eIt is important to properly clean the pH electrode prior to use. A proper cleaning of the electrode must be done with appropriate \u003cspan id=\"gvow3532ka0_3\" class=\"gvow3532ka0\"\u003ecleaning solutions\u003c\/span\u003e in order to remove all the deposits on the sensitive bulb and junction. HI 70635 (wine deposits removal) and HI 70636 (wine stain removal) are tailored made cleaning solutions that remove deposits from your pH electrode to guarantee accurate calibrations for stable. repeatable measurements and long electrode life. HANNA is the only manufacturer to offer tailor made cleaning solutions for winemaking.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 2222-01 (115V) and HI 2222-02 (230V) are supplied with HI 1048P pH electrode. HI 7662 temperature probe. HI 76404N electrode holder. HI 5003 pH 3.00 pH buffer solution. HI 70007 pH 7.01 buffer solution sachet. HI 700636 wine stain cleaning solution sachet. HI 700635 wine deposit cleaning solution sachet. HI 7082S electrolyte solution (30 mL). 5 mL graduated syringe. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±699.9 mV; ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e0.1 (±699.9 mV); 1 (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±0.2 (±699.9 mV); ±1 (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e± 0.2 °C excluding probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Check\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003estatus of electrode condition and response time. status of the buffer solution during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 or 2 point with 7 memorized buffer values (pH 1.68. 3.00. 6.86. 7.01. 9.18. 10.01. 12.45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual or automatic. -20.0 to -120.0°C (-4 to 248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1048P glass body. BNC + pin (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7669\/2W with 1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRS232 opto-isolated serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 Vdc adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e235 x 222 x 109 mm (9.2 x 8.7 x 4.3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.3 kg (2.9 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201048P\"\u003eHI 1048P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH Electrode with CPS™ for Wine\u003cbr\u003e\u003csmall\u003eBNC + Pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207082\"\u003eHI 7082\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution. 3.5M KCl\u003cbr\u003e4 x 30 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205003\"\u003eHI 5003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTechnical Buffer Solution. 3.00 pH. 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207007L\"\u003eHI 7007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070635L\"\u003eHI 70635L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCleaning solution for wine deposits (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070636L\"\u003eHI 70636L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCleaning solution for wine stains (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2076404N\"\u003eHI 76404N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Holder for HI 42xx Type Bench Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20920013\"\u003eHI 920013\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207662\"\u003eHI 7662\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:09:42+12:00","created_at":"2015-09-01T15:16:38+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":1144300,"price_min":1144300,"price_max":1144300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857306117,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI12222-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 2222-02 Wine Analysis pH Benchtop Meter","public_title":null,"options":["Default Title"],"price":1144300,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2222_200_2015.jpeg?v=1465536553"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2222_200_2015.jpeg?v=1465536553","options":["Title"],"media":[{"alt":"HI 2222-02 Wine Analysis pH Benchtop Meter - Acorn Scientific","id":21302706275,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2222_200_2015.jpeg?v=1465536553"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi2222_200_2015.jpeg?v=1465536553","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for wine analysis\u003c\/li\u003e\n\u003cli\u003eDedicated 3.00 pH buffer for calibration in the wine pH range\u003c\/li\u003e\n\u003cli\u003eClog-resistant electrode\u003c\/li\u003e\n\u003cli\u003epH Calibration Check™ electrode diagnostics\u003c\/li\u003e\n\u003cli\u003eElectrode condition on display \u003c\/li\u003e\n\u003cli\u003eCalibration alarm timeout\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003ePC interface via USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 2222 is the only pH meter on the market today that allows for automatic pH calibration at pH 3 and pH 7. With the dedicated 3.00 pH buffer for wine calibration in the wine pH range. any error due to calibration will be minimized. The HI 2222’s Calibration Check™ diagnostics along with the included HI 1048P clogging resistant pH electode further enhances measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eThis wine analysis instrument also features logging of up to 100 samples. GLP (\u003cspan id=\"gvow3532ka0_1\" class=\"gvow3532ka0\"\u003eGood Laboratory Practice\u003c\/span\u003e) capability. and a USB interface for the transfer of data to a PC.\u003cbr\u003eIn the process of \u003cspan id=\"gvow3532ka0_2\" class=\"gvow3532ka0\"\u003ewine making\u003c\/span\u003e. most pH measurements are made in the must. A pH electrode gets dirty quickly when measuring the pH of must because sediments build up on both the pH measuring bulb and pH electrode junction. This becomes a big problem during the actual pH measurement if the electrode has not been properly cleaned. A dirty pH electrode can give results that are up to 0.5 pH inaccurate — even after a pH calibration has just been performed.\u003c\/p\u003e\n\u003cp\u003eConventional pH meters do not warn the user when the pH electrode is dirty. A common example of this occurs just after calibrating the instrument — the pH electrode is immersed into the pH 7 buffer and the reading is lower than expected (pH 6.8 or 6.9 instead of 7.0). HI 2222 uses HANNA ’s unique technology to detect when the electrode is dirty and gives a warning during calibration.\u003c\/p\u003e\n\u003cp\u003eIt is important to properly clean the pH electrode prior to use. A proper cleaning of the electrode must be done with appropriate \u003cspan id=\"gvow3532ka0_3\" class=\"gvow3532ka0\"\u003ecleaning solutions\u003c\/span\u003e in order to remove all the deposits on the sensitive bulb and junction. HI 70635 (wine deposits removal) and HI 70636 (wine stain removal) are tailored made cleaning solutions that remove deposits from your pH electrode to guarantee accurate calibrations for stable. repeatable measurements and long electrode life. HANNA is the only manufacturer to offer tailor made cleaning solutions for winemaking.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 2222-01 (115V) and HI 2222-02 (230V) are supplied with HI 1048P pH electrode. HI 7662 temperature probe. HI 76404N electrode holder. HI 5003 pH 3.00 pH buffer solution. HI 70007 pH 7.01 buffer solution sachet. HI 700636 wine stain cleaning solution sachet. HI 700635 wine deposit cleaning solution sachet. HI 7082S electrolyte solution (30 mL). 5 mL graduated syringe. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±699.9 mV; ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e0.1 (±699.9 mV); 1 (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e±0.2 (±699.9 mV); ±1 (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e± 0.2 °C excluding probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Check\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003estatus of electrode condition and response time. status of the buffer solution during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 1 or 2 point with 7 memorized buffer values (pH 1.68. 3.00. 6.86. 7.01. 9.18. 10.01. 12.45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual or automatic. -20.0 to -120.0°C (-4 to 248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 1048P glass body. BNC + pin (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7669\/2W with 1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRS232 opto-isolated serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 Vdc adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e235 x 222 x 109 mm (9.2 x 8.7 x 4.3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.3 kg (2.9 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%201048P\"\u003eHI 1048P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003epH Electrode with CPS™ for Wine\u003cbr\u003e\u003csmall\u003eBNC + Pin Connection\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207082\"\u003eHI 7082\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution. 3.5M KCl\u003cbr\u003e4 x 30 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%205003\"\u003eHI 5003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTechnical Buffer Solution. 3.00 pH. 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207007L\"\u003eHI 7007L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.01 pH Buffer Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070300L\"\u003eHI 70300L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Storage Solution\u003cbr\u003e1 x 500 mL bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070635L\"\u003eHI 70635L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCleaning solution for wine deposits (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2070636L\"\u003eHI 70636L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCleaning solution for wine stains (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2076404N\"\u003eHI 76404N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Holder for HI 42xx Type Bench Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%2092000\"\u003eHI 92000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® Compatible Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%20920013\"\u003eHI 920013\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=002001\u0026amp;ProdCode=HI%207662\"\u003eHI 7662\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}
HANNA HI 2222-02 Wine Analysis pH Benchtop Meter
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














