{"id":1582064261,"title":"HANNA HI 723 Checker HC ® - Chromium VI. HR","handle":"hi723","description":"\u003cp style=\"text-align: justify;\"\u003eThere are two natural forms of ionic chromium. the hexavalent ion. Cr (VI) and the trivalent Cr (III). Cr (III) is much less toxic than Cr (VI) and seldom found in potable waters. Cr (VI). however. is toxic to humans and is found in water. Even though the toxic effects from Cr (VI) in drinking water are not well documented. it is a suspected carcinogen. The maximum permissible level or Cr (VI) allowed to be released into the waterways is 50 ppb. Its level in drinking water is normally much lower and a lever higher than 3 ppb is suggestive of industrial pollution.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eBy monitoring this parameter with the HANNA HI 723 Checker®HC. serious health and safety risks can be avoided.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 723 Checker®HC is extremely simple to use. First. zero the instrument with your water sample. Next. add the reagent. shake vigurosly for 10 seconds. Last. place the vial into the Checker®HC. press the operational button for about 3 seconds and the display will show the countdown prior to the measurement or. alternatively. wait for 6 minutes and press operational button. When the timer ends the meter will perform the reading. The Checker®HC displays concentration in ppb of chromium VI. It’s that easy.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 723 Checker®HC is supplied with sample cuvettes with caps (2 ea.). power reagents for chromium VI HR (6). battery and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/hannainst.com\/manuals\/ist723_03_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 999 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±5% of reading ±5 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptaion of the ATSM. Manual of Water and Enviornmental Technology. D 1687-92. Diphenylcarbohydrazide method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2016-09-01T16:14:04+12:00","created_at":"2015-09-01T15:02:09+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["category_photometers","Manufacturer_Hanna Instruments"],"price":8900,"price_min":8900,"price_max":8900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857023685,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI723","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 723 Checker HC ® - Chromium VI. HR","public_title":null,"options":["Default Title"],"price":8900,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-chrom-vi-hoch-839_1-1_2015.jpeg?v=1443494421"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-chrom-vi-hoch-839_1-1_2015.jpeg?v=1443494421","options":["Title"],"media":[{"alt":"HI 723 Checker HC ® - Chromium VI. HR - Acorn Scientific","id":21265449059,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-chrom-vi-hoch-839_1-1_2015.jpeg?v=1443494421"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-chrom-vi-hoch-839_1-1_2015.jpeg?v=1443494421","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003eThere are two natural forms of ionic chromium. the hexavalent ion. Cr (VI) and the trivalent Cr (III). Cr (III) is much less toxic than Cr (VI) and seldom found in potable waters. Cr (VI). however. is toxic to humans and is found in water. Even though the toxic effects from Cr (VI) in drinking water are not well documented. it is a suspected carcinogen. The maximum permissible level or Cr (VI) allowed to be released into the waterways is 50 ppb. Its level in drinking water is normally much lower and a lever higher than 3 ppb is suggestive of industrial pollution.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eBy monitoring this parameter with the HANNA HI 723 Checker®HC. serious health and safety risks can be avoided.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 723 Checker®HC is extremely simple to use. First. zero the instrument with your water sample. Next. add the reagent. shake vigurosly for 10 seconds. Last. place the vial into the Checker®HC. press the operational button for about 3 seconds and the display will show the countdown prior to the measurement or. alternatively. wait for 6 minutes and press operational button. When the timer ends the meter will perform the reading. The Checker®HC displays concentration in ppb of chromium VI. It’s that easy.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 723 Checker®HC is supplied with sample cuvettes with caps (2 ea.). power reagents for chromium VI HR (6). battery and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/hannainst.com\/manuals\/ist723_03_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 999 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±5% of reading ±5 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptaion of the ATSM. Manual of Water and Enviornmental Technology. D 1687-92. Diphenylcarbohydrazide method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}